background image

General Operation 

 
Introduction 

Your CASCO NANO CUBE is designed for ease of use and to provide optimal 
livestock conditions. 
 
The Cube has it’s own filtration sump unit located at the bottom of the rack. The 
water is completely separate from that in anything you might have next to it. 
 
The Cube can automatically top-up from your stores freshwater supply. Under 
normal operation there is no need to top-up the systems manually, check to see 
if your system has been set up this way, you will find a Red ball cock in the 
sump, if you press it down water will come out further up the fitting. 
 
Each aquarium compartment has it’s own water supply and drain, however the 
corner aquariums do flow through an adjoing one to get back to the sump. Flow 
to each Level of the tanks is individually adjustable with the inlet tap. 
 

Switching the systems on and off 

The systems are connected to your stores main electrical supplies. 
 
The lights for all the Cube can be switched on and off using the relevant switch in 
the filter area under the tanks  
 
The Cube filtration systems are connected to a 24-hour supply and must under 
normal circumstances be switched on at all times. 

Switching off the filtration 

system for any significant length of time will be harmful to your fish!

 

 
If an individual component needs to be switched off or disconnected, this can be 
done via the plug strip mounted at the bottom of each rack above the filter 
system: 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 

Содержание Nano Cube

Страница 1: ...Nano Cube Owner Manual ...

Страница 2: ...ent has it s own water supply and drain however the corner aquariums do flow through an adjoing one to get back to the sump Flow to each Level of the tanks is individually adjustable with the inlet tap Switching the systems on and off The systems are connected to your stores main electrical supplies The lights for all the Cube can be switched on and off using the relevant switch in the filter area...

Страница 3: ...d excess cable back behind the system and reconnect the plug Check that the equipment is operating correctly Water Flow Each aquarium compartment has it s own Inlet and Outlet Flow into the aquarium compartment can be adjusted or shut off by turning the Blue tap It is important to check daily that a good flow of filtered water is reaching each aquarium compartment IMPORTANT DO NOT switch off the t...

Страница 4: ...rect operation of equipment Aquarium Water Flow Check that sufficient water is flowing into every aquarium compartment Adjust taps as necessary Check that all aquarium outlets are clear of any debris Clean as necessary Poor water flow will lead to low water quality and temperature fluctuations that can lead to livestock loss Water Temperature Check the temperature of the water in each tropical sys...

Страница 5: ...t Elbow towards you It will slide off the System Drain Line allowing you to easily remove the filter bag Fit a new filter bag from your spare set Refit the Drain Outlet Elbow and reconnect the pump Take a few moments to check that everything is operating as it should on the restarted system and that water is flowing correctly to all aquarium compartments The dirty filter bags can be turned inside ...

Страница 6: ...ow Outlet Check that the Overflow Outlet in the Filter Pump Chamber is free from obstruction Automatic Top Up Check that the Automatic Top Up is working correctly by pushing down gently on the red float Water should come out of the white top up pipe to fill the pump chamber Glowing UV ends Correct water level with pump fully submerged Overflow outlet clear from obstruction Push down red float to c...

Страница 7: ...or flood Fortnightly Maintenance Checks and Tasks The following checks and tasks need to be carried out at least once every two weeks Depending on the amount and type of livestock in your systems it may be necessary to carry them out more often Carry out the following in addition to the daily weekly tasks above Clean Filter Foam Unplug the filter pump as detailed above to stop water flowing Remove...

Страница 8: ...system Fault Reason Action No flow to the aquariums Pump not working Pump Blocked No Water in Reservoir Inlet Taps Turned off Check Pump Operation Check Electrical Supply Clean Pump Check Top Up Operation If necessary manually fill pump chamber Do not allow pump to run dry Check taps are open and adjusted correctly Aquarium Overflowing Inlet Taps Turned to high Outlet Pipe Blocked Turn taps down R...

Страница 9: ...xtension lead Fuse Check mains plugs from rack correctly connected Contact Casco No Power to All Systems Electrical Fault on Distribution Check Main Store Electrical Panel System Pump Noisy No water Low level in Pump Chamber Pump failing Switch off Pump and allow reservoir to refill Check Top Up System Operation Replace Pump Contact CASCO IMPORTANT If you cannot solve the problem with your system ...

Отзывы: