PROBLEM

POSSIBLE REMEDIES

  PROBLEM

POSSIBLE REMEDIES

..

FAN WILL NOT START

•Check main circuit fuses, circuit breakers, or wall switch position. Check all wire connections, making

sure the power is turned off during this inspection.

•Pin connectors are not making good contact. Check the connections in the switch housing and under the

top cover.

•Battery weak - install fresh battery.
•Fan receiver defective - replace.
•Check the frequency setting:  Turn power off, at the circuit breaker, only for the fan not functioning for

at least 5 seconds; turn the power back on; within 20 seconds press the Hi, Med, and Lo buttons (in that
order) to set the frequency of the fan to the control.

FAN WOBBLES OR SHAKES

•Be sure canopy pin is properly set into the slot on the ball.

EXCESSIVELY

•Check that bladeholders have not been bent during installation and blades are balanced.
•Hanger bracket and/or ceiling outlet are loosely attached:  Make sure that the hanger bracket is tightly.

attached to the ceiling outlet box. Make sure that the downrod assembly is secured firmly.

•Downrod is loosely attached to downrod base: Make sure that all screws are securely tightened .

FAN NOISY DURING

•Check and tighten light fixture retaining screws, glass shade screws and/or the light bulb(s).

OPERATION

•Tighten canopy screws and mounting plate assembly. Check that the wire nuts inside the canopy and

switch housing are not touching the metal parts or have fallen off the wire splices. Tighten as necessary.

•Tighten blade holders to flywheel (or direct drive motor)/and blade to bladeholder screws.
•Make sure all screws in the motor housing are snug, but not overly tight. Defective bulb: Replace bulb.

DOES NOT RUN ON

•If new, “break-in” may be required - run at higher speed for several days.

LOW SPEED

BATTERY LIFE

•Not using Alkaline batteries: Replace with Alkaline batteries.

SEEMS SHORT

VERSA•TOUCH 2

• LIGHT O.K., NO FAN:

 Pin connectors are not making good contact, check 9 pin connector under top cover.

• FAN O.K., NO LIGHT;

 Defective receiver; Replace receiver. Defective motor; Replace motor. Broken socket; Replace socket. Defective receiver;

Replace Receiver.

• FAN AND LIGHT ON FULL, NO CONTROL;

 Defective receiver; Replace Receiver.

• MISSING ONE SPEED:

 Defective receiver; Replace Receiver.

• FAN DOESN’T CHANGE SPEED, LIGHT O.K.:

 Replace receiver.

• FAN O.K., LIGHT NOT DIM:

 Defective receiver; Replace Receiver.

• NO REVERSE:

 Defective receiver; Replace Receiver.

• FAN OPERATES ONLY WHEN TRANSMITTER IS CLOSED:

 Check antenna wire is not touching metal plate.

• FAN STARTS WORKING BY ITSELF:

 Frequency interference; Change frequency as described on Page 11.

TROUBLESHOOTING

2

1.This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions:  (1) this device may not cause harmful interference,and (2) this device must accept any

interference received,including interference that may cause undesired operation.

2.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against

harmful interference in a residential installation.  This equipment generates,uses and can radiate radio frequency energy and,if not installed and used in accordance with the instructions,may cause

harmful interference to radio communications. However,there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or

television reception,which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or

relocate the receiving antenna, Increase the separation between the equipment and receiver, Connect the equipment into an outlet on a circuit different from that to which the receiver is connected,

Consult the dealer or an experienced radio/TV technician for help.  Note: Any changes or modifications to the transmitter or receiver not expressly approved by Casablanca Fan Company may void one’s

authority to operate this remote control.

For questions or to locate the nearest Casablanca Authorized Service Center call toll free:
1-888-227-2178 or visit us on the web at:  www.CasablancaFanCo.com

Содержание Campana

Страница 1: ...CAMPANA OWNER S MANUAL 3 Speed Model Only...

Страница 2: ...nsulted if you are unsure This fan is designed to be installed on an existing electrical outlet box The outlet box must be UL Listed for ceiling fan installations if it is not a new box must be instal...

Страница 3: ...sure to provide plenty of clearance to avoid damage from pool cues In low ceiling locations our optional Low Ceiling Adaptor LCA available at extra cost can be used to gain 31 2 In kitchens be sure to...

Страница 4: ...g hardware provided with the outlet box ADDITIONAL HARDWARE 21 4 x 8 32 ROUNDED HEAD SCREW 2 FLAT WASHER 2 1 x 8 32 ROUNDED HEAD SCREW 2 PERMA LOCK HARDWARE DOWNROD BALL ASSEMBLY ALLEN SET SCREW 1 4 2...

Страница 5: ...CANOPY SCREW 4 OUTLET BOX MOUNTING HARDWARE Note On sloped ceilings align the canopy opening towards the top or room peak Proceed with installation as follows Step 1 Route the wires from the ceiling...

Страница 6: ...wire nut BLUE wire and BLACK power wire from fan to BLACK power wire in ceiling outlet box Secure with wire nut Step 4c W 80 Wiring Connections GREEN leads from mounting plate and fan to GROUND con du...

Страница 7: ...LACK wires are on opposite sides of the canopy and all wires are clear of the canopy opening Step 6 Install canopy hatch with the last canopy screw and lock washer To do this tilt the fan body away fr...

Страница 8: ...R 4 PER BLADE BLADE BLADE HOLDER BLADE TO BLADE HOLDER INSTALLATION INSTALL BLADE ASSEMBLY TO FAN SWITCH HOUSING ASSEMBLIES 3 SPEED SWITCH HOUSING AND CAP ASSEMBLY Step 10 Attach each blade blade hold...

Страница 9: ...N Make sure that no wires are pinched by the switch housing before tightening screws Step 11 For 3 Speed models only Hold the switch housing up to the fan and con nect the motor plug to the switch hou...

Страница 10: ...FAN ONLY WALL CONTROLS The W 40 and W 24 wall controls provide four speed control of fan from a convenient wall location The W 40 and W 24 are designed to replace a standard wall switch and will fit w...

Страница 11: ...4 different speed settings No light fixture is used Set the FAN pull chain switch to the HIGH speed setting No changes in household or fan wiring are required The fan may be turned ON and OFF by the...

Страница 12: ...sure all screws in the motor housing are snug but not overly tight Check that the wire nuts inside the canopy and switch housing are not touching the metal parts or have fallen off the wire splices T...

Страница 13: ...itch Step C Install and tighten screws by hand only INNER MOUNTING HOLES CONTROL BRACKET STANDARD TOGGLE SWITCH SWITCH COVER PLATE Rocker Light Switch Step A Break off the two tabs by pushing outward...

Страница 14: ...i Med and Low buttons in that order within 20 seconds Step 4 The fan should now function properly VERSA TOUCH 2 CHANGING FREQUENCY SETTING You will only have to change the dip switch settings in the r...

Страница 15: ...efective receiver Replace receiver Defective motor Replace motor Broken socket Replace socket Defective receiver Replace Receiver FAN AND LIGHT ON FULL NO CONTROL Defective receiver Replace Receiver M...

Страница 16: ...STAR approved Solid State test method Ceiling fan airflow is measured in cubic feet per minute CFM Power use is measured in watts To maximize energy savings Choose a fan with high airflow efficiency C...

Страница 17: ...COPYRIGHT 2003 CASABLANCA FAN COMPANY U S PATENT PENDING PRINTED IN CHINA 761 CORPORATE CENTER DRIVE POMONA CA 91768 TOLL FREE 888 CASA 1ST 227 2178 www CasablancaFanCo com...

Отзывы: