C
AMPANA
™
O
WNER
’
S
M
ANUAL
3-Speed Model Only
Страница 1: ...CAMPANA OWNER S MANUAL 3 Speed Model Only...
Страница 2: ...nsulted if you are unsure This fan is designed to be installed on an existing electrical outlet box The outlet box must be UL Listed for ceiling fan installations if it is not a new box must be instal...
Страница 3: ...sure to provide plenty of clearance to avoid damage from pool cues In low ceiling locations our optional Low Ceiling Adaptor LCA available at extra cost can be used to gain 31 2 In kitchens be sure to...
Страница 4: ...g hardware provided with the outlet box ADDITIONAL HARDWARE 21 4 x 8 32 ROUNDED HEAD SCREW 2 FLAT WASHER 2 1 x 8 32 ROUNDED HEAD SCREW 2 PERMA LOCK HARDWARE DOWNROD BALL ASSEMBLY ALLEN SET SCREW 1 4 2...
Страница 5: ...CANOPY SCREW 4 OUTLET BOX MOUNTING HARDWARE Note On sloped ceilings align the canopy opening towards the top or room peak Proceed with installation as follows Step 1 Route the wires from the ceiling...
Страница 6: ...wire nut BLUE wire and BLACK power wire from fan to BLACK power wire in ceiling outlet box Secure with wire nut Step 4c W 80 Wiring Connections GREEN leads from mounting plate and fan to GROUND con du...
Страница 7: ...LACK wires are on opposite sides of the canopy and all wires are clear of the canopy opening Step 6 Install canopy hatch with the last canopy screw and lock washer To do this tilt the fan body away fr...
Страница 8: ...R 4 PER BLADE BLADE BLADE HOLDER BLADE TO BLADE HOLDER INSTALLATION INSTALL BLADE ASSEMBLY TO FAN SWITCH HOUSING ASSEMBLIES 3 SPEED SWITCH HOUSING AND CAP ASSEMBLY Step 10 Attach each blade blade hold...
Страница 9: ...N Make sure that no wires are pinched by the switch housing before tightening screws Step 11 For 3 Speed models only Hold the switch housing up to the fan and con nect the motor plug to the switch hou...
Страница 10: ...FAN ONLY WALL CONTROLS The W 40 and W 24 wall controls provide four speed control of fan from a convenient wall location The W 40 and W 24 are designed to replace a standard wall switch and will fit w...
Страница 11: ...4 different speed settings No light fixture is used Set the FAN pull chain switch to the HIGH speed setting No changes in household or fan wiring are required The fan may be turned ON and OFF by the...
Страница 12: ...sure all screws in the motor housing are snug but not overly tight Check that the wire nuts inside the canopy and switch housing are not touching the metal parts or have fallen off the wire splices T...
Страница 13: ...itch Step C Install and tighten screws by hand only INNER MOUNTING HOLES CONTROL BRACKET STANDARD TOGGLE SWITCH SWITCH COVER PLATE Rocker Light Switch Step A Break off the two tabs by pushing outward...
Страница 14: ...i Med and Low buttons in that order within 20 seconds Step 4 The fan should now function properly VERSA TOUCH 2 CHANGING FREQUENCY SETTING You will only have to change the dip switch settings in the r...
Страница 15: ...efective receiver Replace receiver Defective motor Replace motor Broken socket Replace socket Defective receiver Replace Receiver FAN AND LIGHT ON FULL NO CONTROL Defective receiver Replace Receiver M...
Страница 16: ...STAR approved Solid State test method Ceiling fan airflow is measured in cubic feet per minute CFM Power use is measured in watts To maximize energy savings Choose a fan with high airflow efficiency C...
Страница 17: ...COPYRIGHT 2003 CASABLANCA FAN COMPANY U S PATENT PENDING PRINTED IN CHINA 761 CORPORATE CENTER DRIVE POMONA CA 91768 TOLL FREE 888 CASA 1ST 227 2178 www CasablancaFanCo com...