- 24 -
CAL 1
MAXIMUM CAPACITY SETTING
Available Setting Range : 1kg ~ 999,999kg
KEY
FUNCTION
DISPLAY
DESCRIPTION
CAL 1
CAL 1 Condition
Increase or
decrease
set value
5000
5000kg
Move one
digit to left
10000
10000kg
ENTER
Next
Menu
Save the value and go to CAL 2
Note 1.
The maximum capacity means the maximum weight that the scale can
measure.
CAL 2
MINIMUM DIVISION SETTING
Available Setting Range : 0.001kg ~ 100kg
KEY
FUNCTION
DISPLAY
DESCRIPTION
CAL 2
CAL 2 Condition
1
1kg
Increase or
decrease
set value
0.01
0.01kg
ENTER
Next
Menu
Save the value and go to CAL 3
Note 1.
The minimum division means one division
Note 2.
External resolution should be within 1/20,000.
(External resolution= a division/maximum weight).