17
Unit Weight Lack Alarm
If unit weight is within the range of unit weight lack, Lack of Unit Weight
lamp will be flickered. (Refer to TABLE 2)
TABLE 2.
MODEL MAX.
WEIGHT
RANGE OF SAMPLE RANGE
OF UNIT
WEIGHT LACK
WEIGHT LACK
25AC 25kg 0
125g 0
2.5g
50AC 50kg 0
250g 0
5g
100AC 100kg
0
500g 0
10g
SPECIFICATIONS
MODEL
CAPACITY
MAX. TARE WEIGHT
SAMPLE LACKING
UNIT WEIGHT LACKING
FUNCTION
DISPLAY DIGIT
TEMPERATURE RANGE
POWER SOURCE
POWER CONSUMPTION
PRODUCT SIZE
PRODUCT WEIGHT
25 AC 50 AC 100 AC
25 kg
5 g 50 kg
10 g 100 kg
20 g
9.995 kg 19.99 kg 39.98 kg
0
125 g 0
250 g
0
500 g
0
2.5 g 0
5 g 0
10 g
PCS, U.W., TARE, ZERO
5 / 5 / 5
5°C
35°C
AC 220 V / 60 Hz
APPROX. 10 W
420(W)
615(D)
968(H)
APPROX. 17 kg
16
TABLE 1. Range of the Tare Weight
MODEL
MAX. WEIGHT
MAX. TARE WEIGHT
MIN. WEIGHT
25AC 25kg 9.995kg
5g
50AC 50kg 19.99kg
10g
100AC 100kg
39.98kg
20g
5. Computing Error Alarm
This scale has an alarm function for the samples that are either very small or very
light. This function shows the possibility of calculating errors.
Sample Weight Lack Alarm
If the sample weight is within the range of sample weight lack,
(Refer to TABLE 2) Lack of Sample lamp will be flickered.
PCS
U.W.
TARE
ZERO
PCS
U.W.
TARE
ZERO
Place the samples on
the platter.
Enter the number of the
samples.
To get the unit weight,
press the PCS key.
For example, if this scale is 50AC, 0.2kg(200g) is within the range of sample lacking.
(Refer to TABLE 2) In this case, Lack of Sample lamp will be flickered.
Until the flickering disappears, increase the sample weight, then the unit weight can be
changed and the number of samples will be calculated automatically.
NOTE: If the counting number exceed the "99,999", then the number display
shows "-----", and you will hear a beep sound.