background image

15

PCS

U.W.

TARE

ZERO

PCS

U.W.

TARE

ZERO

Enter the weight of the 

container.

Press the TARE key. 

Then you will see the weight 
of the container.

Place the sample with 

container on the platter.

NOTE: If the weight of the container is 2kg, you have to type 200 (

), because 

the weight of the container is displayed as 2.00kg in the weight display (

). 

If the weight of the container is 900g, you have to type 90, then the weight 
display shows the 0.90kg(900g).

PCS

U.W.

TARE

ZERO

Remove the sample with 

container from the platter. 

Press the TARE key.

14

Place the container on 

the platter.

Press the TARE key.

A) Unknown Tare

If you do not know the weight of the container, you may use this method.
Make sure that ZERO lamp is on.

Place the sample in the 

container. Then the weight 
display will show only weight 
of the sample.

Remove the container and press the TARE 

key.

B) Known Tare

If you know the weight of the container you may use this method.
Make sure that ZERO lamp is on.

PCS

U.W.

TARE

ZERO

PCS

U.W.

TARE

ZERO

Содержание 100AC

Страница 1: ...AC TYPE Counting Scale OWNER S MANUAL ...

Страница 2: ...CTIONS 6 INSTALLATION 9 OPERATIONS 10 1 WhenYouKnowtheNumberoftheSamples 10 2 WhenYouKnowtheUnitWeightofaSample 11 3 CheckingtheLimitedQuantity 12 4 HowtoUseTareFunction 13 5 ComputingErrorAlarm 16 SPECIFICATIONS 17 SPECIFICATIONSFORCEMARKING 18 ...

Страница 3: ...enter the bubble of the leveling gauge inside the indicated circle Lift the platter then you will see the leveling gauge Leveling gauge 4 Do not put the scale on a sudden temperature changes PRECAUTIONS Place the scale on a flat and stable surface Do not put the scale on a sudden impact to the platter Keep away from the wet place Check the power voltage Plug into a power outlet 10 minutes before o...

Страница 4: ...NUMBER DISPLAY This display shows the number of the sample NUMBER WEIGHT UNIT WEIGHT PCS ZERO TARE LACK OF SAMPLE LACK OF UNIT WEIGHT kg g PER PCS CAPACITY 50kg x 10g PCS U W TARE ZERO ON OFF KEY FUNCTION 0 9 Numeric keys used to enter numerical data Used to enter the unit weight with decimal point Used to set the limited quantity KEYS FUNCTIONS 6 PREFACE NAMES AND FUNCTIONS Thank you for the purc...

Страница 5: ...nit weight you can get the number of the samples by pressing this key Used to set the ZERO point Used to clear TARE entries and to enter TARE weight Used to enter the limited quantity Turns the display on or off Set all displays to Zero KEYS FUNCTIONS AC power cord terminal Fuse holder Load cell connecter terminal Span hole Power line Head guide Head Stop bolt Support cover Support ON OFF switch R...

Страница 6: ...to know the unit weight Insert load cell connector into the load cell terminal Plug the scale into an AC socket and make sure that the socket s power is within the scale s operating range Turn ON the power switch Press ON OFF key on the keyboard The scale count up to 9 s and you will hear a beep PCS U W TARE ZERO PCS U W TARE ZERO PCS U W TARE ZERO 2 When You Know the Unit Weight of a Sample When ...

Страница 7: ...weight of a container being used for a sample The TARE key subtracts the weight of the container 12 PCS U W TARE ZERO Remove the samples and press the C key 3 Checking the Limited Quantity If the number of samples exceed the limited quantity the display will flicker with an alarm This function helps unit packaging or quantity checking Make sure that the zero lamp should be on PCS U W TARE ZERO PCS...

Страница 8: ... then the weight display shows the 0 90kg 900g PCS U W TARE ZERO Remove the sample with container from the platter Press the TARE key 14 Place the container on the platter Press the TARE key A Unknown Tare If you do not know the weight of the container you may use this method Make sure that ZERO lamp is on Place the sample in the container Then the weight display will show only weight of the sampl...

Страница 9: ...EIGHT 25AC 25kg 9 995kg 5g 50AC 50kg 19 99kg 10g 100AC 100kg 39 98kg 20g 5 Computing Error Alarm This scale has an alarm function for the samples that are either very small or very light This function shows the possibility of calculating errors Sample Weight Lack Alarm If the sample weight is within the range of sample weight lack Refer to TABLE 2 Lack of Sample lamp will be flickered PCS U W TARE...

Страница 10: ...scale Make sure that the power switch is OFF Plug the scale into AC socket and make sure that the socket s power is within the scale s operating range Turn the power switch ON 5 The socket outlet shall be installed near the equipment and shall be easily accessible 6 Do not pour water directly on the scale Use the plastic cleaner to clean your scale 7 Changes or modifications not expressly approved...

Отзывы: