RSV Series
–
In-Line Vertical Multi-Stage, Ring Section Pump
December 2016
7
Table 3. Recommended Coupling Bolt Torque Values (ft-lbs)
Drawing Reference
120-5
120-6
Model
Bolt Size
Specification
Bolt Size
Specification
RSV3
M6
6 ft-lbs 8.5 N-m
M6
6 ft-lbs 8.5 N-m
RSV5
RSV10 2
–
RSV10 3
M6
6 ft-lbs 8.5 N-m
M6
6 ft-lbs 8.5 N-m
RSV10 4
–
RSV10 12
M8
15 ft-lbs 20 N-m
RSV10 13
–
RSV10 16
M10
30 ft-lbs 40 N-m
RSV18 2
M6
6 ft-lbs 8.5 N-m
M6
6 ft-lbs 8.5 N-m
RSV18 3
–
RSV18 5
M8
15 ft-lbs 20 N-m
RSV18 6
–
RSV18 11
M10
30 ft-lbs 40 N-m
RSV32 1
M6
6 ft-lbs 8.5 N-m
M6
6 ft-lbs 8.5 N-m
RSV32 2-2
–
RSV32 3-2
M8
15 ft-lbs 20 N-m
RSV32 3
–
RSV32 10-1
M10
30 ft-lbs 40 N-m
M12
50 ft-lbs 68 N-m
RSV45 1-1
–
RSV45 1
M8
15 ft-lbs 20 N-m
RSV45 2-1
–
RSV 45 7-2
M10
30 ft-lbs 40 N-m
M12
50 ft-lbs 68 N-m
RSV64 1-1
M8
15 ft-lbs 20 N-m
RSV64 1-0
–
RSV64 4-0
M10
30 ft-lbs 40 N-m
M12
50 ft-lbs 68 N-m
VI. SERVICE AND REPAIR.
For service and repair for each specific RSV model,
please refer to Section as indicated in Table 4.
A. MOTOR INSTALLATION ON BARE PUMP.
WARNING
When lifting the pump/motor, use appropriate
crane (or hoist), check position and tightness of
lift system so that weight of the pump is not
unbalanced. Failure to observe this precaution
can result in serious accidents.
A.1 Procedure for mounting motors for the
following models:
RSV3 2
–
RSV3 12
RSV5 2
–
RSV5 6
RSV32 1
RSV10 2
–
RSV10 3
RSV18 2
WARNING
Before attempting to disassemble the pump,
the electrical power supply to the driver must
be locked and tagged in the “OFF” position to
prevent injury or death to personnel servicing
the pumping unit.
1. Follow general safety and electrical instructions
on the motor nameplate.
2. Remove coupling guard from the pump end.
3. Carefully loosen the screws on the coupling.
4. Position the motor vertically over the pump with
the keyways lined up on the motor and the
pump. Then lower the motor into place. If
necessary rotate the motor so that the mounting
bolt holes line up with the corresponding holes
in the pump bracket.
Содержание RSV Series
Страница 1: ...RVS IN LINE VERTICAL MULTISTAGE FOR HIGH PRESSURE APPLICATIONS BEFORE 12 2016 ...
Страница 3: ......
Страница 7: ...This page left intentionally blank ...
Страница 40: ...This page intentionally left blank ...
Страница 41: ...DEC 2016 ATEX REV 0 ...
Страница 42: ...RVS IN LINE VERTICAL MULTISTAGE FOR HIGH PRESSURE APPLICATIONS AFTER 12 2016 ...
Страница 44: ......
Страница 63: ...RSV In Line Vertical Multi Stage Ring Section Pump RSV 13 02 EN 15 Figure 6 Use Starting and Running B ...