8
Open the Tripod to the desired height and lock all safety knobs.
Place the MASTER MK2 Fluid Head on the Tripod base and rotate
until it matches the steel notch; tighten the Head firmly by screwing
in the knob (6) underneath the flat base. Check the illuminated bubble
level (11) and modify the legs angle if needed. In case of low visibility,
press button (15) for illuminated bubble level and to activate the dig-
ital displays. Lights will turn off automatically after approximately 30
seconds.
Lock the horizontal position with lever (4) red position, insert pan lock
(12) and turn both tilt drag selector (10) and counterbalance selector
(14) to position “0”.
To release the Camera plate (7) push the red safety button (8) and
open the slide lock lever (9) completely till to position 2, then remove
the Camera plate.
Attach the Camera plate under the Camera assembly and firmly se-
cure it with both screws. Try to place the Camera plate centered un-
der the Camera system, keeping in mind the position of the center of
gravity (CG).
Place the Camera on the top of the MASTER MK2, leaning sidewards
against the left side of the Head (slide lock side), then push the as-
sembly into horizontal position until you feel the click of the slide lock
lever (9), which will be in position 1 (at this point the Camera plate is
clamped but still moving fore-and-aft).