background image

11 

CABINET MAINTENANCE 

CASTERS 

Caster bearings are equipped with Zerk grease fittings so that they 
may be easily lubricated with a grease gun. Lubricate bearings at 
least once every six months.   

 

REPLACING THE DOOR GASKET 

1.  Remove the screws located under the gasket on the cabinet. 

2. 

Remove the gasket and discard.

 

3. 

Install the new gasket and replace the screws.

 

 

REVERSING THE DOOR 

Reversing the door takes about 30 minutes & requires two people. 

1.  Using a small screwdriver, pry off the hinge covers and set 

aside. Removing the covers will allow access to the inside 
hinge screws. Remove the three screws that hold each hinge 
to the cabinet.  DO NOT REMOVE THE SCREWS THAT 
HOLD THE HINGES TO THE DOOR. Remove the door, tak-
ing care not to let it fall. 

2.  Remove the door strike plate and screws adjacent to the door 

opening on the cabinet.  Reinstall door strike plate and screws 
on opposite side of the cabinet. 

3.  Screw hinges onto opposite side of the door. 

4.  With the help of another person, hold door up to the cabinet 

and attach with the screws removed in step one.  Before tight-
ening the screws, be sure the door is flush, level and square.  
Replace the hinge covers. 

WARNING: 

DO NOT perform 
these procedures 

while the cabinet is turned on 
or heated.  Turn off the power 
and wait for the cabinet to cool 
to room temperature. 

 
CAUTION:

 

Do not move cabinet 
unless door is se-

curely closed.  Serious dam-
age to hinges and door may 
result if bumped into tables, 
walls, or other equipment when 
the doors are open. 

Содержание HWC10S1XM

Страница 1: ...ATIONS 3 UNPACKING INSPECTION FREIGHT DAMAGE 4 INSTALLATION STARTUP 5 CONTROL PANEL LAYOUT 6 NORMAL OPERATION 7 8 FOOD HOLDING GUIDE 9 REGULAR CLEANING PROCEDURES 10 CABINET MAINTENANCE 11 WIRING DIAG...

Страница 2: ...pose as described in the manual a This equipment is specifically designed to hold pre cooked food at temperature b This equipment is intended for use in commercial establishments only c This equipment...

Страница 3: ...840 716 5 127 403 188 HWC36S1XM full size 36 36 54 1 2 1384 76 3 8 33 1 16 28 3 16 1940 840 716 5 127 475 215 Precision engineered heat ducts with blower for even heat and humidity 90 humidity attain...

Страница 4: ...personnel before leaving the factory Upon acceptance of this shipment the transportation company assumes full responsibility for its safe delivery IF SHIPMENT ARRIVES DAMAGED 1 VISIBLE LOSS OR DAMAGE...

Страница 5: ...into a grounded outlet with a minimum 20 Amp 120VAC 60HZ single phase electrical service 6 Set POWER switch to the ON position 7 Set temperature dial to 190 F Do not fill humidity pan Set humidity di...

Страница 6: ...cator Add water to reservoir when lit Humidity Knob Rotate clockwise to in crease humidity set point rotate counter clockwise to reduce humidity set point Match Low Medium and High locations within sa...

Страница 7: ...bottom and work to the top This keeps food hotter and eliminates spillage onto lower items Due to food safety concerns we recommend that the holding temperature should not be set below 140 F PROOFING...

Страница 8: ...The trough can be removed and emp tied by simply sliding it off the bolts at the base of the door Humidity Setting Temperature Setting Low Medium High 100 F to 130 F Yellow Zone L 30 Yellow Zone M 60...

Страница 9: ...30 Pasta 175 F 79 C 75 60 Pastries 165 F 74 C 20 30 Pizza uncovered 180 F 82 C 10 30 Pizza boxed 180 F 82 C NONE REQUIRED 60 Poppers Deep Fried 190 F 88 C NONE REQUIRED 25 Poultry Whole bone in 175 F...

Страница 10: ...b with soft cloth as directed on package Fingerprints needed or similar products Rub in direction of grain of stainless steel Do not use on vinyl trim Stubborn Daily Any chloride free Apply with damp...

Страница 11: ...REMOVE THE SCREWS THAT HOLD THE HINGES TO THE DOOR Remove the door tak ing care not to let it fall 2 Remove the door strike plate and screws adjacent to the door opening on the cabinet Reinstall door...

Страница 12: ...Logix9 SERIES WITH ANALOG CONTROL 120 VOLT 2100 WATT 17 5 AMP 1 PH 60 HZ 12 WIRING DIAGRAMS...

Страница 13: ...17 0011 Cord grip Verify w factory Heat element 1000 watt water reservoir 18612 0315 Heat element 1000 watt air 18614 0291 Fan motor 18614 0314 Muffin fan 18603 5018 Fan blade for motor 18614 0291 290...

Страница 14: ...nician Element hi limit trip defective Call service technician Takes too long to get to temperature Improper voltage Call service technician to verify incoming voltage matches cabinet specifications U...

Страница 15: ...o be given if found by CARTER HOFFMANN to be defective CARTER HOFFMANN neither makes nor assumes and does not authorize any other person to make or assume any obligation or liability in connection wit...

Отзывы: