5
UNPACKING AND INSTALLATION
WARNING:
Risk of personal injury
Installation procedures must
be performed by a qualified technician
with full knowledge of all applicable
electrical codes. Failure can result in
personal injury and property damage.
CAUTION:
Electrical Shock Hazard
The ground prong of the power cord is
part of a system designed to protect
you from electric shock in the event of
internal damage. DO NOT cut off the
large round ground prong or twist a
blade to fit an existing receptacle.
IMPORTANT:
Power cord is 10' long.
If necessary, contact a li-
censed electrician to install
an appropriate 20 amp electrical cir-
cuit with NEMA 5-20R receptacle. DO
NOT use an extension cord.
IMPORTANT:
Damage to unit due to being
connected to the wrong volt-
age or phase is
NOT
cov-
ered by warranty.
GROUNDING INSTRUCTIONS
This appliance is equipped with a cord having a grounding wire
with a grounding plug which must be plugged into an outlet that is
properly installed and grounded. In the event of an electrical short
circuit, grounding reduces the risk of electric shock by providing an
escape wire for the electrical current.
WARNING-Improper use of the grounding can result in a risk
of electric shock.
Consult a qualified electrician or service agent if
the grounding instructions are not completely understood, or if
doubt exists as to whether the appliance is properly grounded.
Unpack the cart and heating unit. Ensure that all packing materials
and protective plastic has been removed from the unit. Inspect all
components for completeness and condition.
NOTE: DO NOT
discard the carton or other packing materials until
you have inspected the appliance for hidden damage and tested it
for proper operation. Refer to
SHIPPING DAMAGE CLAIM PROCE-
DURE
on PAGE 14 of this manual.
Appliance should be thoroughly cleaned before use. See CLEANING
INSTRUCTIONS, page 6.
The cabinet is shipped with the batteries already installed and pre-
charged. Prior to use, batteries will require a 24-hour refreshing
charge to ensure best operation.
Plug the heating unit into a properly grounded NEMA 5-20R electri-
cal receptacle.
DO NOT MODIFY CORD PLUG.
Charge batteries for 24 hours.
For first time operation of the cabinet, run on AC (wall) power for 60
minutes. Do not load product into the cabinet. Allow the heat to re-
move any residual oils which may adhere to inside metal surfaces. A
slight emission of smoke is common during the first few hours of
operation.
Before using, familiarize yourself with the
heater controls. Read entire manual before
operating this cart.
ELECTRICAL INFORMATION:
120 volts, 60 Hz, single phase, 1300 watts, 10.8 Amps. Ten foot 3
wire rubber cord with 3 prong grounding plug. NEMA 5-20P.
BATTERY INFORMATION:
DC (battery) Power: Two 12 volt 539 watts/cell batteries. Non-
spillable Absorbed Electrolyte type; Electrical Storage Valve Regu-
lated Lead-Acid (VRLA) Battery with Absorbed Glass Mat (AGM)
Содержание GTH12