6
If necessary, contact a licensed electri-
cian to install an appropriate 15 amp
electrical circuit with correct NEMA re-
ceptacle. Ensure that the plug is acces-
sible after installation.
DO NOT use an extension cord.
Connect city water supply and city drain to the 3/8” NPT female fittings at the
back of the unit (Fig. 7). Access to the connections will be at the back of the cabi-
net.
NOTE: This unit is to be installed with adequate backflow protection to
comply with all applicable federal, state and local codes.
City water connection
must be less than 10 feet from the cabinet
and
no
higher than 6 feet
from the connections.
A minimum of 35 PSI is required to
feed the cabinet.
Install the lights and diffuser panels (instructions on page 20)
The 120V electrical outlet should be within 6 feet of the cabinet. Do not use an
extension cord. Connect to a properly grounded outlet according the electrical
specifications for the cabinet. See page 2 for specifications.
Pipes that have not been used regularly should be cleaned and flushed
with running water before connecting the cabinet.
Check the condition of the water inlet hose and drain hose prior to con-
nection. They should not be twisted, crushed, tangled or leaking. Do not
use connection hoses that have been previously connected to other appli-
ances.
If the unit is built in to a wall or structure, make sure that it can be easily
moved to access to the back and side panels for service and mainte-
nance.
INSTALLATION AND STARTUP
Installation procedures must be
performed by a qualified technician with
full knowledge of all applicable electrical
and plumbing codes. Failure could
result in personal injury and property
damage.
Damage to unit due to being connected
to the wrong voltage or phase is
NOT
covered by warranty.
The ground prong of the power cord is
part of a system designed to protect you
from electric shock in the event of inter-
nal damage.
DO NOT cut off the large round ground
prong or twist a blade to fit an existing
receptacle.
CAUTION:
Electrical Shock Hazard
IMPORTANT:
Power cord is 10' long
IMPORTANT:
Not under warranty
WARNING:
Risk of personal injury
Fig. 7
City fill connection:
3/8” NPT female
fitting
City drain connection:
3/8” NPT female fitting
Due to varying water quality in different
municipalities, make sure that your facil-
ity water is filtered of sediment and
chemicals before hooking up the fill
lines. Sediment from hard and soft wa-
ter may eventually clog up the pumps
and filters.
IMPORTANT:
FILTERED WATER
REQUIRED
WARNING:
Tipping hazard
Anchor straps
must
be used
to secure unit to a wall. Unit
must
be anchored, using straps along
with the anchor points located in the
upper corners of the back of the unit to
structural supports in the wall behind the
unit.
**IT IS VERY IMPORTANT THAT THIS NEXT STEP IS
COMPLETED CORRECTLY**
7. Pull both ends of the
strap as show in Figure
5, make sure that the
strap does not slide
through easily
8. Pull the strap tight and tie up the rest of the strap neatly as shown in Figure 6
Figure 5
Figure 6