5
Countertop Mounting
NOTE:
CNH12LP, CNH18LP and CNH28LP drop-in models are not
intended to be dropped into an enclosed compartment.
Counter
must be made of a non-combustible material, located away and
shielded from combustible materials, clean and free of debris.
Lo-
cate and drill four mounting holes in counter top.
If desired, you may remove the legs from unit and secure to counter
top using threaded mounting holes previously occupied by legs.
Seal the perimeter of unit where it
meets the counter top with a food grade
silicone sealant.
Drop-In Mounting
Counter-top must be non-combustible
and made of stainless steel, clean and
free of debris. Verify cut-out dimensions
of the counter-top.
CNH12LP:
20.75”D
x 24.25” W;
CNH18LP:
20.75”D x
30.25” W.
CNH28LP:
27.125”D x
27.125”W.
Warmer is equipped with CarterLocks,
uniquely designed turn-out tabs which
secure the top flange of the warmer to
the counter top.
Apply food-grade silicone sealant to the
underside of the warmer top flange prior
to setting the unit into the cutout. Set the
warmer into the counter top cut-out.
After installation, verify that the tabs on
the CarterLocks are turned out to lock
the warmer into the counter. A flathead screwdriver may be used to
turn the tabs.
Apply a thin bead of food-grade silicone sealant around the flange to
seal it to the counter.
INSTALLATION
GROUNDING INSTRUCTIONS
This appliance is equipped with a cord having a grounding wire with a
grounding plug which must be plugged into an outlet that is properly installed
and grounded. In the event of an electrical short circuit, grounding reduces
the risk of electric shock by providing an escape wire for the electric current.
WARNING—Improper use of the grounding can result in a risk of elec-
tric shock.
Consult a qualified electrician or serviceman if the grounding
instructions are not completely understood, or if doubt exists as to whether
the appliance is properly grounded.
The ground lug of this appliance must be connected to a suitable building
ground.
IMPORTANT:
Power cord is 6' long.
If necessary, contact a licensed
electrician to install an appropriate
20 amp electrical circuit with correct
NEMA receptacle. DO NOT use an
extension cord.
WARNING:
Risk of personal injury
Installation procedures must be
performed by a qualified technician
with full knowledge of all applicable
electrical codes.
Failure can result in personal injury
and property damage.
IMPORTANT:
NOT UNDER WARRANTY
Damage to unit due to be-
ing connected to the wrong voltage
or phase is
NOT
covered by war-
ranty.
CAUTION:
Risk of personal injury
Unit is not waterproof, to
avoid electrical shock keep unit and
counter from being submerged in
water. Do not operate if unit has
been submerged in water.
CAUTION:
Electrical Shock Hazard
The ground prong of the
power cord is part of a system de-
signed to protect you from electric
shock in the event of internal dam-
age.
DO NOT
cut off the large round
ground prong or twist a blade to fit
an existing receptacle.
CAUTION:
To reduce the risk of fire,
the appliance is to be
mounted on surfaces of noncom-
bustible material only.
IMPORTANT: NOT UNDER WARRANTY
Damage caused by leaks due to improper installa-
tion is
NOT
covered by warranty
24.25” or 30.25” W
20.75”
D