![Carson Reflex Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/carson/reflex/reflex_instruction-manual_2564710020.webp)
GB
// 20
TECHNICAL SPECIFICATIONS
• Read these operating instructions carefully before starting operation and keep them for future use!
• The integrated circuits on the switching module are sensitive to electrostatic charging. Do not touch these components before you have „discharged“ yourself (e.g. by touching a radiator or
other earthed device).
• Ensure adequate ventilation during installation.
• Protect the module from moisture, moisture and the effects of heat.
• The switching module may only be operated with the supply voltage specified in the technical data and used for the application described.
• Wiring may only be carried out when the power is off.
• Operation is not suitable for children under the age of 14.
SAFETY INFORMATION
Supply voltage:
4.0 - 8.0 V (via RC receiver)
Power consumption:
approx. 10 - 25mA
Switching outputs:
4x, negative switching
Switching voltage:
max. 20 V DC
Switching current:
max. 4 A per output
Total current of all outputs: max. 10 A
Switching modes:
15 different switching modes, freely selectable
RC signal zero point:
Fixed at 1,500 ms
Dimensions:
23 x 15 x 4 mm
Cable length:
approx. 30 cm
Weight:
12 g
Содержание Reflex