8”
SAER MOTORS
3 PHASE SUBMERSIBLE
MOTOR SPECIFICATIONS
& TESTING PARAMETERS
HORSEPOWER
MOTOR DIA.
MAKE & RPM
VOLTS
PHASE
Hz
SERVICE
FACTOR
FULL
LOAD
AMPS
MAX
LOAD
AMPS
LINE to LINE
RESISTANCE
IN OHMS
LOCKED
ROTOR
AMPS
40 HP
8”
SAER
1800 RPM
460V
3 PH
60 Hz
1.15
53.0
60.0
0.50
-
0.70
N/A
50 HP
8”
SAER
1800 RPM
460V
3 PH
60 Hz
1.15
67.0
74.0
0.13
-
0.33
N/A
60 HP
8”
SAER
1800 RPM
460V
3 PH
60 Hz
1.15
79.0
88.0
0.23
-
0.43
N/A
Carry Pumps, Inc.
·
1360 Prospect Ave.
·
Caro, MI 48723
www.carrypumps.com
·
800
-
492
-
2779
·
ALL ELECTRICAL WORK
MUST BE PERFORMED
BY A LICENSED
ELECTRICIAN
DO NOT
test Winding resistance with the
motor connected to the Control Box or Var-
iable Frequency Drive (VFD).
A bound pump will cause locked rotor amps
and over
-
current fault/shut down. Check
for obstructions in the pump and/or the
amps on the Black wire at start
-
up.
Test the windings by using a Multimeter or
Ohmmeter to measure Ohms (Resistance)
between Yellow or White to Red, Yellow or
White to Black, and Red to Black.
IMPORTANT
Resistance measured between any combi-
nation of wires should be a similar value.