background image

Carry Pumps, Inc. 

·

 1360 Prospect Ave. 

·

 Caro, MI  48723 

 

www.carrypumps.com 

·

 800

-

492

-

2779 

·

 [email protected]

 

• 

Do not use a Carry Pumps

™ 

Stainless Steel Submersible 

High

-

Volume Axial

-

Flow Pump in a swimming area.

 

• 

Electrical controls must be installed observing all applicable 
state and local codes. 

 

• 

A local disconnect is recommended near the controls for ease 
of servicing.

 

• 

A good earth ground must be provided at the electrical 
service entrance using a metal grounding stake.

  

 

• 

The pump must be properly grounded to protect personnel 
from a 

serious or fatal electrical shock hazard

, and the 

pump motor from lightning.

 

• 

Use of a Lightning Arrestor is highly recommended.

 

• 

The level control wiring must be encapsulated or low voltage 
for safety.

 

 

 

 
 

PRODUCT USE & 

 

SAFETY INFORMATION

 

Содержание CP12 Series

Страница 1: ...CP12 SERIES 3 PHASE OWNERS MANUAL Carry Pumps Inc 1360 Prospect Ave Caro MI 48723 www carrypumps com 800 492 2779 sales carrypumps com CARRY STAINLESS STEEL AXIAL FLOW SUBMERSIBLE PUMP...

Страница 2: ...3 13 CP12 Series Pump 40HP 460V 3PH w 13 Degree Impeller GENERAL DESCRIPTION CP12 Carry CP12 Series High Volume Pump HORSEPOWER 0400 40 Horsepower 0500 50 Horsepower 0600 60 Horsepower VOLTAGE PHASE 4...

Страница 3: ...cal codes A local disconnect is recommended near the controls for ease of servicing A good earth ground must be provided at the electrical service entrance using a metal grounding stake The pump must...

Страница 4: ...Severe dam age will result to the pump and motor if water freezes around them Remove any construction debris muck and sludge from the sump bottom before the installation and initial start up These ob...

Страница 5: ...PSI required The location of the point plotted on the chart determines the horsepower of pump and degree of impeller required CP12 SERIES 3 PHASE SUBMERSIBLE PUMP CURVES 50HP MOTOR 17 20 or 22 5 Impel...

Страница 6: ...SPECIFICATIONS A WATER LEVEL IN SUMP D B C E TOP VIEW BOTTOM VIEW 18 DISCHARGE RECOMMENDED FOR BEST PERFORMANCE HP A MINIMUM WATER PUMP ON B OVERALL HEIGHT C MINIMUM WATER PUMP OFF D 18 ANSI FLANGE D...

Страница 7: ...Ave Caro MI 48723 www carrypumps com 800 492 2779 controls carrypumps com ALL ELECTRICAL WORK MUST BE PERFORMED BY A LICENSED ELECTRICIAN DO NOT test Winding resistance with the motor connected to the...

Страница 8: ...t can cause the appearance of water hammers Setting a stopping ramp to slowly stop the motor OPERATING FREQUENCY LIMITS Maximum working frequency should never exceed the nominal frequency of the motor...

Страница 9: ...greement are in lieu of all other warranties express or implied including without limitation any warranties of merchantability or fitness for a particular purpose said warranties being expressly discl...

Страница 10: ...repaired or replaced pump to Purchaser freight prepaid The repair or replacement of the pump shall not extend the duration of the one year warranty term GOVERNING LAW This warranty shall be governed a...

Отзывы: