Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53480254-01
Printed in U.S.A.
Form 48HC-4-6-03SI
Pg 1
1-2020
Replaces: 48HC-4-6-02SI
Installation Instructions
CONTENTS
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 1
MODEL NUMBER NOMENCLATURE AND
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Rated Indoor Airflow . . . . . . . . . . . . . . . . . . . . . . . . . . 3
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Jobsite Survey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Step 1 — Plan for Unit Location . . . . . . . . . . . . . . . 10
Step 2 — Plan for Sequence of Unit Installation . . 10
• SLAB MOUNT (HORIZONTAL UNITS ONLY)
• ALTERNATE UNIT SUPPORT (IN LIEU OF CURB OR
Step 7 — Convert to Horizontal and Connect
Ductwork (When Required) . . . . . . . . . . . . . . . . . 13
Step 8 — Install Outside Air Hood . . . . . . . . . . . . . . 14
• ECONOMIZER AND TWO POSITION DAMPER HOOD
PACKAGE REMOVAL AND SETUP (FACTORY
• ECONOMIZER AND TWO-POSITION HOOD
Step 9 — Units with Hinged Panels Only . . . . . . . . 15
Step 10 — Install Flue Hood . . . . . . . . . . . . . . . . . . . 15
Step 11 — Install Gas Piping . . . . . . . . . . . . . . . . . . 16
• FACTORY OPTION THRU-BASE CONNECTIONS
(GAS CONNECTIONS)
Step 12 — Install External Condensate Trap and
Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Step 13 — Make Electrical Connections . . . . . . . . . 19
• UNITS WITH FACTORY-INSTALLED NON-FUSED
• UNITS WITHOUT FACTORY-INSTALLED NON-
• FACTORY-OPTION THRU-BASE CONNECTIONS
• UNITS WITHOUT THRU-BASE CONNECTIONS
• HUMIDI-MIZER® CONTROL CONNECTIONS
• LOW AMBIENT CONTROL (FACTORY OPTION)
• COMFORTLINK (FACTORY OPTION)
Economi$er® X (Factory Option) . . . . . . . . . . . . . . .41
• ECONOMIZER MODULE WIRING DETAILS
• COMPLETING RETURN AIR SMOKE SENSOR
Step 14 — Adjust Factory-Installed Options . . . . . .53
• ECONOMI$ER IV OCCUPANCY SWITCH
• BELT FORCE — DEFLECTION METHOD
Pre-Start and Start-Up . . . . . . . . . . . . . . . . . . . . . . . .54
START-UP CHECKLIST . . . . . . . . . . . . . . . . . . . . .CL-1
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can be
hazardous due to system pressure and electrical components. Only
trained and qualified service personnel should install, repair, or
service air-conditioning equipment.
Untrained personnel can perform basic maintenance functions of
cleaning coils and filters and replacing filters. All other operations
should be performed by trained service personnel. When working
on air-conditioning equipment, observe precautions in the litera-
ture, tags and labels attached to the unit, and other safety precau-
tions that may apply.
Follow all safety codes, including ANSI (American National Stan-
dards Institute) Z223.1. Wear safety glasses and work gloves. Use
quenching cloth for unbrazing operations. Have fire extinguisher
available for all brazing operations.
It is important to recognize safety information. This is the safety-
alert symbol
. When you see this symbol on the unit and in in-
structions or manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, CAUTION,
and NOTE. These words are used with the safety-alert symbol.
DANGER identifies the most serious hazards which
will
result in
severe personal injury or death. WARNING signifies hazards
which
could
result in personal injury or death. CAUTION is used
to identify unsafe practices, which
may
result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which
will
result in enhanced installation, reliability,
or operation.
WeatherMaster
®
48HC**04-06 Single Package Rooftop
Gas Heating/Electric Cooling Unit
with Puron
®
(R-410A) Refrigerant
Downloaded from
Содержание WeatherMaster 48HC Series
Страница 5: ...5 Fig 2 48HC 04 06 Units Built On and After 4 15 2019 Downloaded from ManualsNet com search engine ...
Страница 6: ...6 Fig 3 48HC 04 06 Units Built Prior to 4 15 2019 Downloaded from ManualsNet com search engine ...
Страница 7: ...7 Fig 4 48HC 04 06 Corner Weights and Clearances Downloaded from ManualsNet com search engine ...
Страница 8: ...8 Fig 5 48HC 04 06 Base Rail Details Downloaded from ManualsNet com search engine ...
Страница 9: ...9 Fig 6 48HC 04 06 Thru the Base Charts Downloaded from ManualsNet com search engine ...
Страница 29: ...29 Fig 52 48HC 04 06 ComfortLink Control Wiring Diagram Downloaded from ManualsNet com search engine ...
Страница 33: ...33 Fig 56 48HC 04 06 Control Wiring Diagram Downloaded from ManualsNet com search engine ...
Страница 36: ...36 Fig 59 48HC 04 06 Power Wiring Diagram 575 3 60 Units Downloaded from ManualsNet com search engine ...