62-11637
8–18
8.6.2
Upper Belt Replacement
To remove and reinstall the upper belt (Item 4,
) do the following:
1. Ensure the unit will not start automatically by
disabling any two way communication, placing
the STOP/RUN-OFF switch in the OFF position
and removing the negative battery cable.
2. Loosen the upper idler (5) pivot bolt and release
tension.
3. Open the front doors.
4. Remove the top five bolts that secure the sur-
round to the unit. (See
5. Remove the upper frame support.
6. Pull the unattached surround towards the front
of the unit to gain access to the upper frame
support.
Figure 8.20 Surround
7. Remove the upper fan shroud bolts, and remove
the shroud.
Figure 8.21 Upper Frame Support
8. Remove three bolts (27) that secure condenser
fan (1) to clutch rotor (19). Slide the fan away
from the clutch (2) sufficient to remove the belt.
9. Remove the belt.
10. Reinstall by sliding belt into clutch groove, repo-
sition fan and secure with the three bolts.
Torque bolts 18 to 22 ft/lbs (24.4 to 29.8 Nm).
11. Fit belt in place in grooves and check the center
alignment of the clutch, upper idler and gearbox
sheaves to ensure proper alignment. Pulley mis-
alignment will create excess belt wear and
shorten alternator bearing life. The center line of
all three sheaves must be in line.
12. Pivot the idler to place tension on belt using
hand force only.
Do not use pry bar or excessive
force as it may cause bearing failure
. Using ½
inch drive ratchet in adjustment position (8) to
pivot idler, set belt tension. Use belt tension tool
Carrier Transicold part number 07-00203-00 or
07-00253-00, in accordance with the following
chart. Tighten upper idler pivot bolt.
13. Reinstall upper fan shroud and upper frame
support.
14. Reinstall the five upper mounting bolts to secure
the surround. (See
).
15. Reconnect the negative battery cable. Run unit
15 minutes. Remove battery negative cable,
recheck belt tension and then reconnect nega-
tive battery cable.
8.6.3
Condenser Fan
To remove and reinstall the condenser fan (Item 1,
1. Ensure the unit will not start automatically by
disabling any two way communication, placing
the STOP/RUN-OFF switch in the OFF position
and removing the negative battery cable.
2. Remove the upper frame support an upper fan
shroud.
3. Remove the three bolts (27) that secure the con-
denser fan (1) to the clutch rotor (19) and
remove from unit.
4. Slide new fan in place and secure with three
bolts, torque 18 to 22 ft/lbs (24.4 to 29.8 Nm).
5. Reinstall shroud, torque all shroud bolts 36 to 70
inch/ lbs (4.1 to 6.8 Nm). Reinstall upper frame
support, torque bolts 96 to 120 inch/lbs (10.8 to
13.6 Nm).
6. Start unit and run Pretrip to check operation.
Replacement Belt Initial
Tension
Replacement Belt Ten-
sion After 15 Minutes of
Running Time
Lbs
Nm
Lbs
Nm
140 to 150
190 to 203
70 to 80
95 to 108