RGAP(A,B)XX: Installation and User Instructions

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

3

INSTALLATION

Check Return Air Purifier Components

Carefully remove all items from the box (

Fig. 3

).

A200493

Fig. 3 – Return Air Purifier Components

Materials needed for install

• 1½" x ¼" wood screws - provided by installer (12-14 QTY).

Accessories for completing installation 

• Hinged  return  air  decorative  grille  cover  20"  x  30"  (

Provided  by

installer.

 Use grille cover manufacturer’s instructions for installation

or replacement.)

Identify Mounting Location

Identify a mounting location for the Return Air Purifier.

NOTE: 

The  location  of  the  Return  Air  Purifier  should  be  readily

accessible. Enough room should be provided for the grille and inner unit

to  swing  down  completely  to  facilitate  periodic  replacement  of  the

Return Air Purifier cartridges.

Mount Cabinet

1. Turn off power to the heating and cooling system.
2. Unpackage the product and remove the filter cartridge, per the steps

listed  in 

MAINTENANCE  on pg  7

.  Put  the  filter  cartridge  and

construction filter aside for later use.

3. Verify the  size  of the  rough-in opening  (20-1/8"  x  30-3/16")  and

truss geometry. Trusses should be at 24" on center (

Fig. 4

).

a. If joist blocking does not exist for the RGAPA unit, install three 

blocks and attach to the trusses to form a box to frame in the unit.

b. If blocking has been completed by others, verify the frame 

measurement is correct and make adjustments if needed.

A200494A

Fig. 4 – Rough-in

CAUTION

!

CUT HAZARD

Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and wear

appropriate protective clothing and gloves when handling parts.

CAUTION

!

UNIT DAMAGE HAZARD

Do not attempt to open the unit (lowering the inner unit from the outer

frame) until  it is  fully  installed and hanging flat  and level. To  do  so

could damage the unit or the lowering handle.

Installation Manual

Installation Components

(in accessory bag)

Air Purfier Unit (x1)

(includes Safety Screen and Filter Cartridge installed) 

Construction Filter (x1)

WARNING

!

ELECTRIC SHOCK AND UNIT DAMAGE HAZARD

Failure to follow this warning could result in personal injury or death.

Only a trained, experienced service person should install the Return Air

Purifier. A thorough check of the unit installation should be completed

before  unit  operation.  Before  performing  installation,  service  or

maintenance  operations  on  unit,  turn  off  all  power  to  unit.  Tag

disconnect switch with lockout tag.

WARNING

!

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Before installing  or servicing  system, always turn off main  power to

system. There may be more than one disconnect switch. Lock out and

tag switch with a suitable warning label.

30-3/16”

767 mm

20-1/8”

511 mm

Содержание RGAP Series

Страница 1: ...r property damage Consult a qualified installer service agency or your distributor or branch for information or assistance The qualified installer or agency must use factory authorized kits or accessories when modifying this product Refer to the individual instructions packaged with the kits or accessories when installing Follow all safety codes Wear safety glasses protective clothing and work glo...

Страница 2: ...erminals provide power only when the furnace blower is operating Return Air Purifier RGAPAXX1625 is designed to be powered from the electronic air cleaner EAC terminals on a furnace electronic control Accessory Safety Screen KIT170000 Electrical Power Fusing with Furnace Return Air Purifier RGAPAXX1625 does not include in line fuses as it is designed to be powered from the electronic air cleaner E...

Страница 3: ...blocks and attach to the trusses to form a box to frame in the unit b If blocking has been completed by others verify the frame measurement is correct and make adjustments if needed A200494A Fig 4 Rough in CAUTION CUT HAZARD Failure to follow this caution may result in personal injury Sheet metal parts may have sharp edges or burrs Use care and wear appropriate protective clothing and gloves when ...

Страница 4: ... box knockout 11 Electrical Connections Fig 8 Fig 15 and Fig 16 NOTE Use proper strain relief when installing wiring to junction box a For Furnace Units Connect wiring from the EAC terminals to a unit disconnect switch in the attic and then connect the wiring from the disconnect to the electrical box on the unit using a proper UL rated fitting at the electrical box knockout on the unit Follow stan...

Страница 5: ...on filter 18 Install the filter cartridge Fig 13 in the correct orientation Follow the steps per To replace the Return Air Purifier filter cartridge complete the following steps on p7 and switch on the air purifier IMPORTANT Make sure the metal tabs on the leading edge of the filter case are inserted first They must not be visible after the filter is installed Follow the instructions printed on th...

Страница 6: ...access to the incoming power wiring compartment Affix the ends of the wire or conduit to the fan coil unit and electrical box with proper UL rated fittings 2 Remove the yellow and black primary wires from the fan coil air handler transformer terminals and connect the quick connect piggyback terminals of the quick connect kit leads exiting the air purifier power conduit assembly to the transformer ...

Страница 7: ...ing steps Turn the heating and cooling system power off IMPORTANT Use of any filter cartridge in the Return Air Purifier other than the genuine replacement purifier cartridge listed in the table below will likely result in poor performance and may constitute a safety hazard Do not use any third party air filters in the Return Air Purifier 1 Open the return air grille cover 2 Unlatch the unit and s...

Страница 8: ...Gently stroke the ionization pins with the brush Use a gentle back and forth brushing motion to clean any small accumulations from the tips of the points If desired use a vacuum cleaner with brush attachment to gently vacuum the frame and components of enhancement module Also if an Accessory Safety Screen is installed vacuum the Safety Screen to remove accumulated dust and debris If further cleani...

Страница 9: ...troubleshooting procedures A11370 Fig 22 Removal of Deposits from Ionization Pins CAUTION SAFETY HAZARD Failure to follow this caution may result in personal injury or equipment damage The following instructions are for use by qualified personnel only WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death The following procedures will expose electri...

Страница 10: ...ce flow sensor bypass assembly available as replacement kit KIT161000 One or more of the three airflow sensor contact springs on purifier cabinet downstream rail are bent or damaged Replace flow sensor contact spring assembly included as part of the flow sensor kits KIT160000 and flow sensor bypass kit KIT161000 Table 2 Start Up Error Codes INDICATOR LIGHT CODE EXPLANATION POSSIBLE CAUSE RECOMMEND...

Страница 11: ...ng the Return Air Purifier A200505A Fig 23 Dimensions Table 3 Operating Error Codes INDICATOR LIGHT CODE EXPLANATION POSSIBLE CAUSE RECOMMENDED ACTION 4 FLASHES Ionizer filter current imbalance Dirty Filter Enhancement Module FEM Clean service Return Air Purifier unit Damaged Filter Enhancement Module FEM Replace the filter enhancement module 5 FLASHES Over current fault Excessively dirty Damaged ...

Страница 12: ...Replacement Component Kits and Accessories DESCRIPTION PART NUMBER Filter Enhancement Module FEM KIT145000 Power Supply Assembly KIT159000 Accessory Safety Screen Kit KIT170000 Current Sensing Relay Kit HN72ZA001 Service Quick Kit 344872 751 Included standard with the RGAPBXX1625 Flow Sensor KIT160000 Included standard with the RGAPBXX1625 Flow Sensor Bypass KIT161000 Included standard with the RG...

Отзывы: