RG-10:Service Manual
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
8
24
----
Minimum Cooling
Fan Speed
SERVICE ONLY
Change the minimum cooling fan speed setting
as it relates to RPM.
NOTE: Changing this setting is not
recommended as it may trigger unit
protection protocols.
Displays “
Ch
”. Press
OK
to return the current
minimum cooling fan speed setting. Press
UP
or
DOWN
to select the minimum cooling fan
speed. Press
OK
to confirm.
For example, the unit may be factory set to
fluctuate between 300 and 1000 RPM. If
set to 500, the unit is limited to operating
between 500 and 1000 RPM.
25
----
Maximum Heating
Fan Speed
SERVICE ONLY
Change the maximum heating fan speed
setting as it relates to RPM.
Displays “
Ch
”. Press
OK
to return the current
maximum heating fan speed setting. Press
UP
or
DOWN
to select the maximum heating fan
speed. Press
OK
to confirm.
For example, the unit may be factory set to
fluctuate between 300 and 1000 RPM. If
set to 800, the unit will now be limited to
operating between 300 and 800 RPM.
26
----
Minimum Heating
Fan Speed
SERVICE ONLY
Change the minimum heating fan speed setting
as it relates to RPM.
Note: Changing this setting is not
recommended as it may trigger unit
protection protocols.
Displays “
Ch
”. Press
OK
to return the current
minimum heating fan speed setting. Press
UP
or
DOWN
to select the minimum heating fan
speed. Press
OK
to confirm.
For example, the unit may be factory set to
fluctuate between 300 and 1000 RPM. If
set to 500, the unit is limited to operating
between 500 and 1000 RPM.
27
----
Not available
28
----
Not available
29
----
Not available
30
----
Not available
(Sheet 3 of 3)