RG-10:Service Manual
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
5
Accessing the INQUIRY Mode
1. Simultaneously press
ON/OFF
and
FAN SPEED
for 8 seconds.
a.
The remote is now in the
INQUIRY
mode.
b.
The remote control remains in the
INQUIRY
mode for 1
minute if no other button is pressed.
c.
While in the
INQUIRY
Mode, the remote display cancels all
icons except
AUTO
,
COOL
,
DRY
,
HEAT
and
Battery
Strength
.
d.
The remote control digital display defaults to
0
upon entering
the
INQUIRY
mode.
e.
In the
INQUIRY
mode, each digital code (from 0 to 30) is
accessed by pressing the
UP
or
DOWN
arrows .
f.
The
INQUIRY
information appears on the high wall indoor
unit display in approximately 1 second after accessing the
digital code. Press
OK
to send as well.
g.
In the
INQUIRY
mode, all other buttons and operations are
invalid except for
UP
,
DOWN
and
OK
or the operation to exit
the
INQUIRY
mode.
Remote Controller Service Mode Functions
Note: While in the INQUIRY mode, refer to the following
instructions to enter SERVICE mode for the applicable codes.
Below is a list of
INQUIRY
modes and serviceable functions.
a.
Before using the remote’s service functions, turn
OFF
the
indoor unit with the remote.
b.
Turn
OFF
the power to the outdoor unit for 2 minutes. Turn
the power back
ON
.
c.
Remove the batteries from the remote and wait for the remote
screen to clear. Within 30 seconds of replacing the batteries, use
UP
or
DOWN
to scroll through the
INQUIRY
modes.
d.
To enter the
SERVICE
mode for an applicable
INQUIRY
mode, press
ON/OFF
for 2 seconds.
e.
After
SERVICE
adjustments have been made, press
ON/OFF
for 2 seconds to exit the
SERVICE
mode and return to the
INQUIRY
mode.
f.
Once operations in the
INQUIRY
mode are complete, press
ON/OFF
and
FAN SPEED
for 2 seconds to exit. All buttons
on the remote controller are disabled for 60 seconds
g.
To ensure changes are locked, power down the outdoor unit for
three (3) minutes after all the service mode changes are made.
Read and understand the function changes you wish to make in
advance. Neither the indoor unit nor the remote control displays
the new level of any of the changes made while in the
INQUIRY
mode. Be sure to document the changes you've made to the
system's programming using the
INQUIRY
mode. Once you
complete the changes and exit the
INQUIRY
mode, if additional
changes are made to the programming, the system will not show
the new previously set level(s).
For example, when you first access
CODE 22
,
Heating
Temperature Compensation
, the remote control display
defaults to
0
. If you change it to
-2,
then save and exit out of the
INQUIRY
mode, the next time someone goes back in and
accesses
CODE 22
, the remote’s display will not display
-2
.
Instead it will show
0
because that's the default. If you are unsure
of the previous changes, due to a lack of documentation, you
could press the
DOWN
symbol to the maximum change range of
-6
, then press the
UP
symbol until you are back to
0
, and make
the new adjustments accordingly. Be sure to document the
changes when you are done.
CAUTION