background image

RG-10:Service Manual

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

5

Accessing the INQUIRY Mode

1. Simultaneously press 

ON/OFF

      and 

FAN SPEED

     for 8 seconds.

a.

The remote is now in the 

INQUIRY

 mode.

b.

The remote control remains in the 

INQUIRY

 mode for 1 

minute if no other button is pressed.

c.

While in the 

INQUIRY

 Mode, the remote display cancels all 

icons except 

AUTO

COOL

DRY

HEAT

 and 

Battery

 

Strength

.

d.

The remote control digital display defaults to 

0

 upon entering 

the 

INQUIRY

 mode.

e.

In the 

INQUIRY

 mode, each digital code (from 0 to 30) is 

accessed by pressing the 

UP

 or 

DOWN

 arrows        .

f.

The 

INQUIRY

 information appears on the high wall indoor 

unit display in approximately 1 second after accessing the 
digital code. Press 

OK

 to send as well. 

g.

In the 

INQUIRY

 mode, all other buttons and operations are 

invalid except for 

UP

DOWN

 and 

OK

 or the operation to exit 

the 

INQUIRY

 mode.

Remote Controller Service Mode Functions

Note: While in the INQUIRY mode, refer to the following 

instructions to enter SERVICE mode for the applicable codes.

Below is a list of 

INQUIRY

 modes and serviceable functions.

a.

Before using the remote’s service functions, turn 

OFF

 the 

indoor unit with the remote.

b.

Turn 

OFF

 the power to the outdoor unit for 2 minutes. Turn 

the power back 

ON

.

c.

Remove the batteries from the remote and wait for the remote 
screen to clear. Within 30 seconds of replacing the batteries, use 

UP

 or 

DOWN

 to scroll through the 

INQUIRY

 modes.

d.

To enter the 

SERVICE

 mode for an applicable 

INQUIRY

 

mode, press 

ON/OFF

 for 2 seconds.

e.

After 

SERVICE

 adjustments have been made, press 

ON/OFF

 

for 2 seconds to exit the 

SERVICE

 mode and return to the 

INQUIRY

 mode.

f.

Once operations in the 

INQUIRY

 mode are complete, press 

ON/OFF

 and 

FAN SPEED

 for 2 seconds to exit. All buttons 

on the remote controller are disabled for 60 seconds

g.

To ensure changes are locked, power down the outdoor unit for 
three (3) minutes after all the service mode changes are made.

Read and understand the function changes you wish to make in 
advance. Neither the indoor unit nor the remote control displays 
the new level of any of the changes made while in the 

INQUIRY

 

mode. Be sure to document the changes you've made to the 
system's programming using the 

INQUIRY

 mode. Once you 

complete the changes and exit the 

INQUIRY

 mode, if additional 

changes are made to the programming, the system will not show 
the new previously set level(s). 
For example, when you first access 

CODE 22

,

 Heating 

Temperature Compensation

, the remote control display 

defaults to 

0

. If you change it to 

-2,

 then save and exit out of the 

INQUIRY

 mode, the next time someone goes back in and 

accesses 

CODE 22

, the remote’s display will not display

 -2

Instead it will show 

0

 because that's the default. If you are unsure 

of the previous changes, due to a lack of documentation, you 
could press the 

DOWN

 symbol to the maximum change range of

 

-6

, then press the 

UP

 symbol until you are back to 

0

, and make 

the new adjustments accordingly. Be sure to document the 
changes when you are done.

CAUTION

Содержание RG10 Series

Страница 1: ...his service manual provides the necessary information to use the service functions on the RG10 series wireless remote controller Use the TABLE OF CONTENTS to locate a desired topic Fig 1 RG10A B2S BGE...

Страница 2: ...ies in the remote controller if the remote is not going to be used for 2 or 3 months Dispose old batteries in the appropriate recycle bins Fig 7 Remove the back cover Remote Controller Specification T...

Страница 3: ...llowing is a brief introduction of the remote controller Fig 8 Remote Controller NOTE To alternate between C and F buttons must be pressed gently otherwise the remote will not recognize the command Tu...

Страница 4: ...es the right to change at any time specifications and designs without notice and without obligations 4 REMOTE CONTROLLERS Fig 9 RG10A B2S BGEFU1 Fig 10 RG10B B1 BGEFU1 Fig 11 RG10A5 B1 BGCEFU1 Fig 12...

Страница 5: ...ng the batteries use UP or DOWN to scroll through the INQUIRY modes d To enter the SERVICE mode for an applicable INQUIRY mode press ON OFF for 2 seconds e After SERVICE adjustments have been made pre...

Страница 6: ...un time of 50 mins 11 Terminate after run time of 60 mins 3 T3 Outdoor Coil Temperature SERVICE AND INQUIRY Change the option to control the COOLING and HEATING modes available for use on the unit Pre...

Страница 7: ...fan target frequency SERVICE AND INQUIRY Change the heating frequency upper limit selection in Hz Displays Ch press OK to return the current frequency limit Press UP or DOWN to select the preferred f...

Страница 8: ...ting as it relates to RPM Displays Ch Press OK to return the current maximum heating fan speed setting Press UP or DOWN to select the maximum heating fan speed Press OK to confirm For example the unit...

Отзывы: