Accessories
* Fan motor with ball bearings required.
† See low-ambient controller Installation Instructions for application.
‡ Do not use hard shutoff TXV with Liquid-Line Solenoid Valve.
Accessory usage guideline
* For Tubing line sets greater than 50 ft, refer to Residential Split System Long-Line Application Guideline and Service Manual.
† Only when low-pressure switch is used.
‡ Required for Low-Ambient Controller (full modulation feature) and MotorMaster® Control only.
ORDERING NO.
DESCRIPTION
KAATD0101TDR
Time-Delay Relay — All Sizes
KSALA0301410
Low-Ambient Pressure Switch — All Sizes
P251-0083 (RCD)
Low-Ambient Controller — All Sizes
32LT660004* (RCD)
MotorMaster® Control — All Sizes
KAAFT0101AAA†
Evaporator Freeze Thermostat — All Sizes
KAAWS0101AAA†
Winter Start Control — All Sizes
KSACY0101AAA
Cycle Protector — All Sizes
KSAHS1501AAA
Start Assist — Capacitor and Relay — Sizes 024–048
KSAHS1601AAA
Start Assist — Capacitor and Relay — Size 060
KAACS0201PTC
Start Assist — PTC — All Sizes
KAACH1201AAA
Crankcase Heater — Sizes 024–060
KSATX0201HSZ‡
Thermostatic Expansion Valve (Hard Shutoff) — Sizes 024, 030
KSATX0301HSZ‡
Thermostatic Expansion Valve (Hard Shutoff) — Sizes 036, 042
KSATX0401HSZ‡
Thermostatic Expansion Valve (Hard Shutoff) — Size 048
KSATX0501HSZ‡
Thermostatic Expansion Valve (Hard Shutoff) — Size 060
KSAPX0101PIS
Piston Body — All Sizes
HC38GE231 (RCD)
Ball Bearing Fan Motor — Sizes 024–048
HC40GE232 (RCD)
Ball Bearing Fan Motor — Size 060
KH45LG140 (RCD)
Filter Drier (Suction Line) — Sizes 024–036
KH45LG141 (RCD)
Filter Drier (Suction Line) — Sizes 042–060
KAALS0201LLS‡
Liquid-Line Solenoid Valve — Sizes 024–060
KSASF0101AAA
Support Feet — All Sizes
KAACF0801MED
Coastal Filter — All Sizes
THERMOSTAT/SUBBASE PKG
DESCRIPTION
TSTATCCNAC01-B
Thermostat — Auto Changeover, Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
TSTATCCPAC01-B
Thermostat — Auto Changeover, 7-Day Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
TSTATCCPRH01-B
Thermidistat™ Control — Non-Programmable/Programmable Thermostat with Humidity Control
TSTATCCBAC01-B
Builder’s Thermostat — Manual Changeover, Non-Programmable, °F/°C, 1 Stage Heat,
1-Stage Cool
TSTATXXSEN01-B
Outdoor Air Temperature Sensor
TSTATXXNBP01
Backplate for Non-Programmable Thermostat
TSTATXXPBP01
Backplate for Programmable Thermostat
TSTATXXBBP01
Backplate for Builder’s Thermostat
TSTATXXCNV10
Thermostat Conversion Kit (4 to 5 wire) — 10 Pack
ACCESSORY
REQUIRED FOR
LOW-AMBIENT
APPLICATIONS
(Below 55°F)
REQUIRED FOR
LONG-LINE
APPLICATIONS*
(Over 50 Ft)
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 Miles)
Crankcase Heater
Yes
Yes
No
Evaporator Freeze Thermostat
Yes
No
No
Winter Start Control
Yes†
No
No
Accumulator
No
No
No
Compressor Start Assist
Capacitor and Relay
Yes
Yes
No
Low-Ambient Controller,
MotorMaster® Control,
or
Low-Ambient Pressure Switch
Yes
No
No
Wind Baffle
See Low-Ambient Instructions
No
No
Coastal Filter
No
No
Yes
Support Feet
Recommended
No
Recommended
Liquid-Line Solenoid Valve
or
Hard Shutoff TXV
No
See Long-Line
Application
Guideline
No
Ball Bearing Fan Motor
Yes‡
No