background image

4

51902190402

Specifications are subject to change without notice.

The fan must be kept free of all obstructions to ensure proper
cooling. Contact your dealer for any required service.

Electrical Controls and Wiring

Electrical controls are difficult to check without proper

instrumentation. If there are any discrepancies in the operating
cycle, contact your local dealer and request service.

Refrigerant Circuit

The refrigerant circuit is difficult to check for leaks without the

proper equipment. If inadequate cooling is suspected, contact your
local dealer for service.

EXPLOSION,

BURN

AND

ENVIRONMENTAL

HAZARD

Failure to follow this warning could result in personal

injury, death or property damage.
System under pressure. Relieve pressure and recover all

refrigerant before system repair or final unit disposal. Use

all service ports and open all flow--control devices,

including solenoid valves.

!

WARNING

Unit Panels

After performing any maintenance or service on the unit, be sure
all panels are fastened securely in place to prevent rain from

entering unit cabinet and to prevent disruption of the correct unit
airflow pattern.

Regular Dealer Maintenance

In addition to the type of routine maintenance you might be willing

to perform, your unit should be inspected regularly by a properly
trained service technician. An inspection (preferably each year, but

at least every other year) should include the following:

1. Inspection and, if required, cleaning of the outdoor and

indoor coils.

2. Inspection and, if required, cleaning of the indoor coil drain

pan.

3. Inspection and cleaning of blower wheel housing and

motor.

4. Inspection of all supply--air and return--air ducts for leaks,

obstructions, and insulation integrity. Any problems found

should be resolved at this time.

5. Inspection of the unit base to ensure that no cracks, gaps,

etc., exist which may cause a hazardous condition.

6. Inspection of the unit casing for signs of deterioration.
7. Inspection of all electrical wiring and components to assure

proper connection.

8. Inspection for leaks in the refrigerant circuit. Pressure

check to determine appropriate refrigerant charge.

9. Inspection of compressor oil level by service person to

ensure proper oil level is maintained in the compressor
when it is installed and running.

10. Operational check of the unit to determine working

conditions. Repair or adjustment should be made at this

time.

Your servicing dealer may offer an economical service contract that

covers seasonal inspections. Ask for further details.
Complete service instructions can be found in the unit Installation,

Start--up and Service Instructions.

Warranty Certificate

Your unit has a limited warranty. Be sure to read the warranty
carefully to determine the coverage for your unit.

Before you call for service...

...check for several easily--solved problems.

If insufficient heating or cooling is suspected:

( ) Check for sufficient airflow. Check the air filter for dirt. Check

for blocked return--air or supply--air grilles. Be sure they are open
and unobstructed. If these checks do not reveal the cause, call your

servicing dealer.

If your unit is not operating at all, check the following list for

easy solutions:

(

) Check to be sure that the temperature specified by your User

Interface is set below the indoor temperature during the cooling

season or above the indoor temperature during heating season. Be
sure the User Interface is set to COOL or HEAT and not OFF.
( ) If your unit still fails to operate, call your servicing dealer for

troubleshooting and repairs. Specify the model and serial numbers
of your unit. (Record them in this manual in the space provided.) If

the dealer knows exactly which unit you have, he may be able to
offer suggestions over the phone, or save valuable time through

knowledgeable preparation for the service call.

In Case of Trouble

If you perform the steps above and unit performance is still
unsatisfactory, shut off the unit and call your dealer.

Copyright 2016 International Comfort Products

Lewisburg, TN 37091 USA

Replaces: 51902190401

Содержание PAR524

Страница 1: ...nd model _____________________________________________ _____________________________________________ _____________________________________________ INSTALLATION INFORMATION Date Installed ________________________________ DEALERSHIP CONTACT INFORMATION Company Name_______________________________ Address______________________________________ _____________________________________________ Phone Number ...

Страница 2: ...ailure to follow this warning could result in personal injury and or death Before performing recommended maintenance be sure the main power switch to unit is turned off and lock out tag is installed WARNING CUT HAZARD Failure to follow this caution may result in personal injury When removing access panels or performing maintenance functions inside your unit be aware of sharp sheet metal parts and ...

Страница 3: ...oor filter size for your unit Refer to Fig 2 to access filters installed in the accessory filter rack If using an Accessory Filter Rack refer to the Installation Instructions provided with it for correct filter sizes and quantities Table 1 Indoor Air Filter Data Unit Size Filter Size in mm 24 20x20x1 508x508x25 30 20x24x1 508x610x25 36 42 24x30x1 610x762x25 48 60 24x36x1 610x914x25 To replace or i...

Страница 4: ...or signs of deterioration 7 Inspection of all electrical wiring and components to assure proper connection 8 Inspection for leaks in the refrigerant circuit Pressure check to determine appropriate refrigerant charge 9 Inspection of compressor oil level by service person to ensure proper oil level is maintained in the compressor when it is installed and running 10 Operational check of the unit to d...

Отзывы: