background image

Thermistor, Immersion

 

Installation and Operation

 

 

 

#NSA-A/CP-I-2.5-4X, NSA-A/CP-I-4-4X, NSA-A/CP-I-6-4X, NSA-HH/CP-I-2.5-PB-C, NSA-HH/CP-I-4-PB-C 
NSA-HH/CP-I-6-PB-C 

– 11/15/2019 

 

Specifications subject to change without notice. 

Catalog No. 11-808-785-01 

Page 

5

 of 

5

 

Troubleshooting 

 

Problem 

Solution 

Sensor reading is incorrect 

 

Verify sensor wiring to controller is not damaged and has continuity. 

 

Verify sensor or wires are not shorted together. 

 

Verify controller is setup for correct sensor curve. 

 

Disconnect wires from sensor terminal block, tighten terminal block 
screws down, and take a resistance (ohm) reading with a multimeter. 

 

Compare the resistance reading to the Temperature Vs Resistance 
Curves online: 

http://www.workaci.com/content/thermistor-curves-0

 

 

Verify proper mounting location to confirm no external factors are 
affecting reading. 

Sensor reads infinity/very high 
resistance 

Sensor or wires are open. 

Sensor reads low resistance 

Sensor or wires are shorted together. 

Erratic readings 

 

Condensation on PCB board 

 

Bad wire connections. 

 

 

W.E.E.E. Directive 

 

At the end of their useful life the packaging and product should be disposed of via a suitable recycling center. Do not 
dispose of with household waste. Do not burn. 

 

Содержание NSA-A/CP-I-2.5-4X

Страница 1: ...r Sensing Points One Storage Temperature Range 40 to 85 C 40 to 185 F Operating Humidity Range 0 to 90 RH non condensing Probe Diameter Thermowell Bore Diameter 0 250 6 35mm 0 260 Probe Material Thermowell Material 304 Stainless Steel 304 Series Stainless Steel Wire Size 22 AWG 0 65 mm Thermowell Instrument Process Thread Size NPS National Pipe Straight Female Thread NPT National Pipe Tapered Male...

Страница 2: ...can also be drilled and tapped Figure 2 The pipe system will need to be drained unless a Hot Tap is being used The recommend drill size is 23 32 in 18 mm Drill the hole and tap the hole with 14NPT Always use proper thread sealants on tapered pipe threads of the thermowell Screw the thermowell into the Threadolet Tee or tapped hole using a wrench to tighten it firmly Refill the system and check for...

Страница 3: ... NSA A CP I 4 4X NSA A CP I 6 4X NSA HH CP I 2 5 PB C NSA HH CP I 4 PB C NSA HH CP I 6 PB C 11 15 2019 Specifications subject to change without notice Catalog No 11 808 785 01 Page 3 of 5 Elbow Assembly Figure 3 Tee Mount Assembly Figure 4 Temperature Wiring Figure 5 ...

Страница 4: ...type units are supplied with 2 flying lead wires and all RTD s are supplied with 2 or 3 flying lead wires see Figure 6 The number of wires needed depends on the application Connect thermistor RTD wire leads to controller analog input wires using wire nuts terminal blocks or crimp style connectors All wiring must comply with all local and National Electric Codes After wiring attach the cover to the...

Страница 5: ...rom sensor terminal block tighten terminal block screws down and take a resistance ohm reading with a multimeter Compare the resistance reading to the Temperature Vs Resistance Curves online http www workaci com content thermistor curves 0 Verify proper mounting location to confirm no external factors are affecting reading Sensor reads infinity very high resistance Sensor or wires are open Sensor ...