Manul operation can be used temporarily in case the remote controller is disable or maintenance 
necessary.

OPERATING  INSTRUCTIONS

Manual operation

Manual control 

button

Front panel

AUTO/COOL

NOTE: This manual does not include Remote Controller Operations, see the 
<<Remote Controller Instruction>> packed with the unit for details. 

Operating temperature

Mode

Cooling operation

Heating operation Drying operation

Temperature

1. If  air  conditioner  is  used outside of the above conditions, certain safety  protection 
    features may come into operation and cause the unit to function  abnormally.
2. Room  relative  humidity less  than  80%. If  the air conditioner operates in excess of this
    figure, the surface of the air conditioner may attract condensation. Please sets the vertical
    air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
3. Optimum performance will be achieved within these operating temperature.

Suggestion:

 

 For the unit adopts an Electric Heater, when the outside ambient  temperature is 

O

below 0 C, we strongly recommend you to keep the machine plugged in order to guarantee it 
running smoothly.

Room temperature

 Outdoor temperature

>17 C

0 C    50 C

 <30 C

-15 C    34 C

0 C    50 C

CAUTION:

~

~

~

( -15 C    50 C:For the models with 

low temperature cooling system)

~

>10 C

Open and lift the front panel up to an angle 
until it remains fixed  with a clicking sound.
One press of the manual control button will 
lead to the forced AUTO operation. If press
the button twice within five seconds, the unit
will operate under forced COOL operation.
Close the panel firmly to its original 
position.

The forced cool mode is used for testing 
purposes only. You had better not choose it.
To restore the remote controller operation, 
use the remote controller directly.

CAUTION:

1

3

2

NOTE:

 The unit must be turned off before

operating the manual control button. If the 
unit is operational, continue pressing the 
manual control button until the unit is off.

Содержание LUVH025N

Страница 1: ...LUVH025N LUVH035N LUVH045N LUVH055N LUVH065N LUVH075N...

Страница 2: ...ord is to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personnel only...

Страница 3: ...f such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste Wild disposal of waste in forests and landscapes endangers your hea...

Страница 4: ...ay cause fire and electric shock It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electri...

Страница 5: ...cond itioner to preserve preci sion devices food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off...

Страница 6: ...8 Air filter 9 Manual control button 10 Remote controller holder 11 Remote controller 12 Connecting pipe 13 Drain hose 14 15 Connective pipe 16 Stop valve Connecting cable Indoor unit Outdoor unit 6 5...

Страница 7: ...eating operation 1 2 2 3 4 A Usually it displays the temperature settings When change the setting temperature this indicator begins to flash and stops 20 seconds later B It displays the room temperatu...

Страница 8: ...ance will be achieved within these operating temperature Suggestion For the unit adopts an Electric Heater when the outside ambient temperature is O below 0 C we strongly recommend you to keep the mac...

Страница 9: ...st be disconnected For some models the vertical louver can be adjusted by using the remote controller Please refer to the REMOTE CONTROLLER OPERATION MANUAL for details Do not operate the air conditio...

Страница 10: ...ontrolled under dry operation During the dry operation if the room temperature is lower O than 10 C the compressor stops operation and restarts O until the room temperature is above 12 C To achieve op...

Страница 11: ...cleaning To clean wipe with a soft dry cloth Do not use bleach or abrasives NOTE Supply power must be disconnectd before cleaning the indoor unit Filter Handle A clogged air filter reduces the coolin...

Страница 12: ...o water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and circuit breaker are turned off Caution 4 Remove the A Plasma Dust Collec...

Страница 13: ...high relative humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air cond...

Страница 14: ...If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 9 Auto restart function Power failure during operation will stop the unit compl...

Страница 15: ...ck that plug is securely in wall receptacle Replace the fuse Replace the battery Wait or cancel timer setting Set temperature correctly For detailed method please refer to Using remote control section...

Страница 16: ...CS527 U 2020323A7020 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Отзывы: