4
CLEARANCE TO COMBUSTIBLES
UNIT APPLICATION
LOW---BOY
SIDES
Furnace
1
Supply Plenum and Warm---Air Duct Within 6
Ft of Furnace
1
BACK
Service Clearance
19
TOP
Furnace Casing or Plenum
2
Horizontal Warm---Air Duct Within 6 Ft of
Furnace
2
BOTTOM*
0
FLUE PIPE
Horizontally or Below Pipe
4
Vertically Above Pipe
9
FRONT
8
*Floor may be combustible.
NOTE: Adequate service clearance should be provided over and above these dimensions as required.
PHYSICAL DATA
UNIT SIZE
105---12
120---20
INPUT (BTUH)
70,000
91,000
105,000
119,000
140,000
154,000
HEATING CAPACITY*
57,000
74,000
85,000
97,000
115,000
126,000
NOZZLE
0.40 --- 70A
0.50 --- 70W
0.65 --- 70W
0.75 --- 70B
0.85 --- 70W
1.00 --- 70W
FIRING RATE (GPH)
{
0.50
0.65
0.75
0.85
1.00
1.10
AFUE%
80.5
80.5
80.5
80.0
80.0
80.0
OIL PUMP STAGES/PRESSURE
(PSIG)
1/160
1/170
1/135
1/130
1/140
1/125
HEATING TEMP RISE
_
F
55---85
55---85
55---85
55---85
55---85
55---85
COOLING CFM @ 0.5---IN. WC
STATIC PRESSURE
1250
1250
1250
1865
1865
1865
HEATING CFM @ 0.2---IN. WC
STATIC PRESSURE
840
1130
1425
1555
1890
2080
RECOMMENDED HEATING
BLOWER SPEED
Med---Low
Med---High
High
Med---Low
Med---Low
High
SHIPPING WEIGHT (LB)
235
235
235
260
260
260
BURNER MODEL (3450 RPM)
RIELLO
40---F3
RIELLO
40---F3
RIELLO
40---F3
RIELLO
40---F5
RIELLO
40---F5
RIELLO
40---F5
* Capacity and AFUE in accordance with U.S. Government DOE test procedures.
{
For rating purposes only.
Shaded cells are as factory shipped.
58C
LR