Страница 1: ...KSACN0401AAA High Wall Models KSACN0501AAA Ducted Cassette Models Wired Remote Controller 7 Day Programmable For Ductless Systems OWNER S MANUAL...

Страница 2: ...R DISPLAY 6 PREPARATORY OPERATION 8 OPERATION 9 TIMER FUNCTIONS 15 WEEKLY TIMER 18 FAULT ALARM HANDLING 25 TECHNICAL INDICATION AND REQUIREMENT 25 NOTE To ensure the correct service of the wired contr...

Страница 3: ...ipment Read these instructions thoroughly and follow all warnings or cautions included in the literature and attached to the unit Consult the local building codes and National Electrical Code NEC for...

Страница 4: ...fan coil unit On some systems both the fan coil and the outdoor unit may be on the same disconnect Tag the disconnect switch with a suitable warning label There may be more than one to disconnect EQU...

Страница 5: ...he error code helpful for servicing S 4 way wire layout design S Room temperature display S Weekly schedule Functions S Mode choose Auto Cool Dry Heat Fan S Fan speed Auto Low Med High S Swing on some...

Страница 6: ...2 Fan speed indicator 3 Left right swing indicator 4 Up down swing indicator 5 Not Available 6 Not Available 7 FOLLOW ME function indicator 8 Turbo Auxiliary Heat function indicator 9 _C _F indicator...

Страница 7: ...R DISPLAY 1 Swing Timer Mode Fan speed Lock 2 3 4 3 5 6 7 8 9 10 Copy FOLLOW ME Fig 2 Wired Controller Buttons 1 Mode 2 Power 3 Adjust 4 Fan Speed 5 Swing 6 Timer 7 Day Off Del 8 Copy FOLLOW ME 9 Back...

Страница 8: ...MER for 3s or more The timer displays flashes Timer Fig 3 Timer S Press or to set the date The selected date flashes Fig 4 Day S Date setting is complete and the time setting is ready after pressing T...

Страница 9: ...current time in 1 minute increments Press and hold to adjust the current time ex Monday AM 11 20 Fig 6 Time S The setting is complete after pressing TIMER or if no button is pressed for 10 seconds Tim...

Страница 10: ...mode Mode Fig 9 Operation Mode S Press or to set the room temperature Indoor Setting Temperature Range 62 86_F 17 30_C 62 88_F 17 31_C depending on models Lower Raise Fig 10 or S Press FAN SPEED to se...

Страница 11: ...select whether the room temperature is detected at the indoor unit or at the wired controller Indoor Unit Copy FOLLOWME Fig 12 FOLLOW ME NOTE When the FOLLOW ME function indication appears the room t...

Страница 12: ...an speed Lock Fig 13 LOCK NOTE When the child lock function is activated the lock image appears S PressSWING andTIMER simultaneously for3seconds to disable the keypad tone Press the buttons again for...

Страница 13: ...ction The turbo function sets the unit to reach the user s present temperature in the shortest amount of time possible S When the user presses TURBO in the COOL mode the unit sets to the highest fan s...

Страница 14: ...o activate the LEFT RIGHT SWING function This function is not available on the indoor units Use SWING to adjust the up and down airflow direction Swing Fig 18 Swing S Every time the user presses SWING...

Страница 15: ...er operation stops after the time has passed S On and Off Timer Use to start and stop the air conditioner operation The timer operates and the air conditioner operation starts and stops after the time...

Страница 16: ...onfirm To set the Daily ON OFF and ON OFF TIMER 1 Press TIMER to select the DAY ON or DAY OFF Timer Fig 23 Timer 2 Press CONFIRM and the clock display flashes Confirm Fig 24 Confirm 3 Press the button...

Страница 17: ...17 4 Press or to set the OFF TIMER Fig 26 or 5 Press CONFIRM to finish the setting Confirm Fig 27 Confirm...

Страница 18: ...setting 3 Press and to select the setting time The setting time mode temperature and fan speed appear on the LCD Press CONFIRM to enter the setting time process Confirm Fig 30 ON timer setting for Tim...

Страница 19: ...then press CONFIRM Confirm Fig 34 Room Temperature Setting NOTE This setting is unavailable in the FAN or OFF modes 7 Press and to set the fan speed then press CONFIRM Confirm Fig 35 Fan Speed Settin...

Страница 20: ...0 seconds Weekly Timer Operation 1 Press TIMER to select the week and then the timer starts automatically Timer To start Fig 36 Weekly Timer Operation 2 Press POWER to cancel the timer mode The timer...

Страница 21: ...to revert to the weekly timer Back Turbo Fig 41 Back Turbo To cancel follow the same procedures used for setup NOTE The DAY OFF setting is cancelled automatically after the set day has passed Copy the...

Страница 22: ...timer press CONFIRM Confirm Fig 42 Confirm 2 Press or to select the day to copy from Fig 43 or 3 Press COPY the letters CY appear on the LCD Copy FOLLOW ME Fig 44 COPY 4 Press or to select the day to...

Страница 23: ...ng of Monday to Wednesday Copy FOLLOW ME T Fig 46 Copy 6 Other days can be copied by repeating steps 4 and 5 7 Press CONFIRM to confirm the settings Confirm Fig 47 Confirm 8 Press BACK to revert to th...

Страница 24: ...lect the day of the week and then press CONFIRM Confirm Fig 50 and 3 Press and to select the setting time want to delete The setting time mode temperature and fan speed appear on the LCD The setting t...

Страница 25: ...ing procedures Table 1 Fault Alarm No MALFUNCTION AND PROTECTION DEFINITION DISPLAY DIGITAL TUBE 1 Communication error between wired controller and indoor unit F0 2 The faceplate is abnormal F1 Please...