5
A11294
Fig. 6 -- Gas Conversion Kit
1.9”
(48.76 mm)
1.8”
(46.96 mm)
Drill out with
7/64” drill bit
A11460
Fig. 7 -- Mixer Screw Location
REINSTALL BURNER ASSEMBLY
To reinstall burner assembly:
1. Attach flame sensor to burner assembly.
2. Insert one-piece burner in slot on sides of burner box and
slide burner back in place.
3. Reattach HSI wires to HSI.
4. Verify igniter to burner alignment. See Fig. 8 & 9.
2-1/2-in.
(64.4)
1-1/4-in.
(31.8)
A11405
Fig. 8 -- Igniter Position -- Back View
2 − in.
(2.5 mm
3/8 − in.
3/16− in.
, +0.8 -1.5)
(50 mm)
(9.6 mm)
(4.6 mm)
3/32 − in., +1/32 -3/64-in.
A12932
Fig. 9 -- Igniter Position -- Side View
CONVERT GAS VALVE
UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit damage
The gas valve must be converted and pre--adjusted before
operating on propane gas. If left this way, sooting and
corrosion will occur leading to early heat exchanger failure.
CAUTION
!
FIRE, EXPLOSION, ELECTRICAL SHOCK
HAZARD
Failure to follow this warning could result in personal
injury, death or property damage.
Gas supply MUST be shut off before disconnecting
electrical power and proceeding with conversion.
!
WARNING
ELECTRICAL SHOCK, FIRE OR EXPLOSION
HAZARD
Failure to follow this warning could result in personal
injury, death or property damage.
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF position and
install a lockout tag. There may be more than one
disconnect switch. Lock out and tag switch with a suitable
warning label. Verify proper operation after servicing.
!
WARNING