OWNER
’
S MANUAL - 5
BEFORE INSTALLATION
Test Run Unit-Plug unit into proper power supply
outlet. Refer to operating instructions in this Hand-
book for Comfortable Living. Check all controls for
correct operation, then unplug unit.
Determine Correct Mounting procedure-Refer to
Window Installation or Through-the-Wall installation.
THROUGH-THE-WALL
INSTALLATION
Screwdriver-Philips head type
Power drill (1/8" drill bit)
Pencil
Measuring Tape
Scissors or a razor edged knife
Moving parts can cause personal injury.
Be careful when test-running unit.
Do not operate unit with front grille removed.
WARNING
INSTALLATION INSTRUCTIONS
Step 1
–
Determine Window Location.
Determine a suitable location.
The window where the Air Conditioner is
to be installed should have enough
strength to bear the weight of the
Air Conditioner.
Step 2
–
Measure unit's dimensions.
Step 3
–
Install the Mounting Angle at the Proper
Location
Install the Air Conditioner using the Mounting Angle
or other Mounting Hardware where you want. The
Mounting Angle or other Hardware to be installed
as shown in Fig. 3
For proper drainage, Rear side of the Unit should be
inclined about 10 mm lower.
Step 4 –
Insert unit in window
With 2 people, lift unit and insert it into the
window opening.
WINDOW INSTALLATION
Mounting Angle Installation.
Fig. 3
Two people must work together to avoid personal
injury.
Step 5 –
Finish opening
Close up the gap between unit and
window using the sponge or tape for
insulation as shown in Fig. 3.
Through-the-wall installation can be made in
wood framing or masonry walls with or without
field-supplied wall sleeve. The casing or sleeve
must be installed level so that built-in pitch to out-
side aids in draining condensate. The installation
should be weather-proof outside and finished
inside.
Installations in wood framed or masonry walls can
be made using the casing as a sleeve. Fasten the
casing directly to masonry or studding using field-
supplied masonry or wood screws.
Minimum Louver Clearance
Fig. 4
CAUTION
Содержание International Series
Страница 1: ...140 Casing 150 Casing...