2

For even greater comfort and convenience, match the Infinity

t

ICS furnace with an Infinity air conditioner or heat pump. This will

create a fully communicating system, requiring only 4 thermostat
wires between system components. In some cases, troubleshooting

can even be done from the outdoor unit without entering the home.
Optional remote access through telephone or Internet is also
available when combined with a remote connectivity kit.

Infinity

t

ICS FEATURES / BENEFITS

IdealHumidity

t

—The IdealHumidity system actively controls

both temperature and humidity in the home to provide the best

comfort all year long. Other systems depend on heating or cooling

to manage the moisture in the air. But, IdealHumidity

t

gives the

homeowner the right amount of humidity day and night, even in

mild weather. No other manufacturer can do this! IdealHumidity
saves energy, too. By keeping humidity under control, the

homeowner can set their thermostat to stay comfortable and save

energy—up to 20% off their cooling costs!

IdealComfort

t

—On the coldest days of the year, the Infinity

t

ICS Furnace has the capacity to heat the home. On moderate days
when less heat is required, this furnace will regulate itself to a

lower capacity—providing a comfortable home and minimizing

operating costs.
The patented algorithm and the VariPhase

t

gas valve adjusts the

low heat operating time to match the indoor conditions.

Reliable Heat Exchanger Design

—The primary heat exchanger is

made of aluminized steel for corrosion resistance. The patented
Serpentuff

t

condensing heat exchanger cells are laminated with

polypropylene for greater resistance to corrosion and epoxy coated

externally to prevent oxidation. This break--through in heating
technology helps extend the life of the furnace for years of

dependable performance. The heat exchanger is positioned in the
furnace to extract additional heat. Stainless steel 409 coupling box

componentry between heat exchangers has exceptional corrosion

resistance in natural gas and propane applications.

Power Heat

t

Igniter

—Carrier’s unique SiN igniter is not only

physically robust but it is also electrically robust. It is capable of
running at line voltage and does not require complex voltage

regulators as do other brands. This unique feature further enhances

the reliability of Infinity

t

ICS gas furnace and continues Carrier’s

tradition of technology leadership and innovation in providing a

reliable and durable product.

ComfortFan

t

—Improves comfort all year long by allowing

selection of the continuous fan speed right at the thermostat.

SmartEvap

t

—Allows the system to reduce summertime

humidity levels by nearly 10% over standard systems.

Media Filter Cabinet

—Enhanced indoor air quality in the home

is made easier with our media filter cabinet—a standard accessory

on all deluxe furnaces. When installed as a part of the system, this
cabinet allows for easy and convenient addition of a Carrier high

efficiency air filter.

IdealComfort

t

Control Center

—The microprocessor control

center features state--of--the--art combustion, temperature, and

airflow control to maximize comfort while operating at peak
efficiency.
Combustion control is obtained by taking the inducer motor RPM

reading when the medium--heat pressure switch makes. Using this

information, the microprocessor maintains a consistent air--to--fuel
ratio independent of vent sizing and conditions during all phases of

heat.
The first cycle after power reset provides 16 minutes of low heat

before switching to high heat unless the room thermostat has been

satisfied. Subsequent thermostat cycles provide anywhere from 0
to 16 minutes of low or medium heat depending on the length of

the previous thermostat cycle.
Airflow control is accomplished by the microprocessor and blower

motor. The ECM blower motor is configured by the

microprocessor to react to changes in the static load on the air
delivery system. The ECM blower uses this information to deliver

correct airflow independent of variations in system restrictions.
(For example, dirty filter or zone damper changes during a cycle.)
A special dehumidification function allows direct input from a

thermidistat or humidistat. This input adjusts system airflow for
greater humidity removal and increased cooling comfort during

summer months.

Warranty

—The Infinity

t

ICS heat exchangers come with a

Limited Warranty for lifetime of original owner in single family
residence; 20 years in other residential and commercial

applications. Five--year limited warranty on entire furnace.

Direct Venting or Optional Ventilated Combustion Air

—The

Infinity

t

ICS can be installed as a 2--pipe (Direct Vent) furnace or

as an optional ventilated combustion air application. This provides
added flexibility to meet diverse installation needs.

Electronic

Variable--Speed

Motors

—ECM

Motors

(Electronically Commutated Motor) provide variable--speed
operation to optimize comfort levels in the home year round. They

are also more economical to operate than standard motors.

Sealed

Combustion

System

—Infinity

t

ICS

brings

in

combustion air from outside the furnace, which results in especially

quiet operation.

Insulation

—Foil--faced insulation in heat exchanger section of the

casing minimizes heat loss.

Insulated Blower Compartment

—The acoustical insulation

reduces air and motor noise for quiet operation.

Monoport Burners

—The burners are finely tuned for smooth,

quiet combustion and economical operation.

Bottom Closure

—Factory--installed for side return; easily

removable for bottom return.

Blower Access Panel Switch

—Automatically shuts off 115--v

power to furnace whenever blower access panel is opened.

Quality Registration

—The Infinity

t

ICS is engineered and

manufactured under an ISO 9001 registered quality system.

Certifications

—The Infinity

t

ICS, Model 58MVC units are

CSA. (A.G.A. and C.G.A.) design certified for use with natural and
propane gases. The furnace is factory--shipped for use with natural

gas. A C.S.A. listed gas conversion kit is required to convert

furnace for use with propane gas. The efficiency is GAMA
efficiency rating certified. The Infinity

t

ICS meets California Air

Quality Management District emission requirements.

58MV

C

Содержание INFINITY ICS 58MVC

Страница 1: ...ltration Quality materials are the key behind the Infinityt ICS s outstanding performance Carrier stands behind quality We offer lifetime warranty protection on the heat exchangers the heart of the Infinityt ICS The rest of the furnace is backed by a limited 5 year warranty The Infinityt ICS is available in 5 heat airflow combinations The unit has a 4 way multipoise design and can be installed in ...

Страница 2: ...enter The microprocessor control center features state of the art combustion temperature and airflow control to maximize comfort while operating at peak efficiency Combustion control is obtained by taking the inducer motor RPM reading when the medium heat pressure switch makes Using this information the microprocessor maintains a consistent air to fuel ratio independent of vent sizing and conditio...

Страница 3: ...s for disposal into home drain system Location in furnace varies 10 Heavy duty blower Circulates air across the heat exchangers to transfer heat into the home 11 Serpentufft secondary condensing heat exchanger inside Wrings out more heat through condensation Constructed with polypropylene laminated steel to ensure durability 12 Primary serpentine heat exchanger inside Stretches fuel dollars with t...

Страница 4: ...ensate Neutralizer Kit obtained thru RCD P908 0001 X X X X X Electronic Air Cleaner Model EACB X X X X X Mechanical Air Cleaner Model FILCAB or EZXCAB X X X X X Humidifier Model HUM X X X X X Heat Recovery Ventilator Model HRV X X X X X Energy Recovery Ventilator Model ERV X X X X X UV Lights Model UVL X X X X X EZ Flex Media Filter with end caps 16 in 9 pack EXPXXLMC0016 X EZ Flex Media Filter wi...

Страница 5: ...22 X X X Gas Orifice Kit Size 42 Qty 50 KGAHA0150N42 See Installation Instructions for model altitude and heat value usages Gas Orifice Kit Size 43 Qty 50 KGAHA0250N43 Gas Orifice Kit Size 44 Qty 50 KGAHA0350N44 Gas Orifice Kit Size 45 Qty 50 KGAHA0450N45 Gas Orifice Kit Size 46 Qty 50 KGAHA0550N46 Gas Orifice Kit Size 47 Qty 50 KGAHA1550N47 Gas Orifice Kit Size 48 Qty 50 KGAHA850N48 Gas Orifice K...

Страница 6: ...r Conditioner _F _C Auto Changeover 5 2 Programmable TSTATCCPDF01 B For use with multi stage applications _F _C Auto Changeover 7 Day Programmable TSTATCCPRH01 B For multi use stage configurations _F _C Auto Changeover 7 Day Programmable SYSTXCCUID01 B Infinityt user interface Model HP 2 Stage thermostat must be field converted to air conditioner operation Hybrid Heat thermostat is used with furna...

Страница 7: ...BER MEDIUM HEAT ADJUSTMENT UNDER CAP INLET PRESSURE TAP ON OFF SWITCH HIGH HEAT ADJUSTMENT UNDER CAP BURNER ENCLOSURE REFFERENCE TAP LOW HEAT ADJUSTMENT UNDER CAP MANIFOLD PRESSURE TAP A07422 A92505 A07280 CONTROL CENTER HEAT EXCHANGERS GAS VALVE ______________________________________________________________________________________________________________ Concentric Vent Kit A93086 A concentric ve...

Страница 8: ...d through a series of electronic dampers and remote rooom sensors The 4 zone system is shown ENERGY HEAT RECOVERY VENTILATOR Carrier s energy or heat recovery ventilators exhaust stale indoor air and provide fresh outdoor air to the home while minimizing heat loss and humidity level Especially useful for today s tighter constructed houses Energy recovery ventilator is shown _______________________...

Страница 9: ...5 625 695 800 685 790 875 1005 1095 1260 Heating High 1070 1220 1470 1510 1900 Cooling Max 1400 1375 1975 1950 2060 OUTPUT CAPACITY BTUH ICS Low Upflow 22000 30000 30000 38000 46000 Downflow 23000 30000 30000 38000 46000 Horizontal 21000 30000 30000 38000 45000 Medium Upflow 37000 49000 49000 61000 73000 Downflow 36000 49000 49000 61000 73000 Horizontal 36000 49000 49000 61000 73000 High Upflow 56...

Страница 10: ... 660 660 655 655 655 Medium Heat 890 0 0 50 875 890 890 890 890 High Heat 1510 0 1 0 1510 1510 1510 1510 1510 1500 1490 1480 1470 1455 2 Ton A C Cooling 700 0 0 50 700 690 690 690 690 2 1 2 Ton A C Cooling 875 0 0 50 835 845 855 860 865 3 Ton A C Cooling 1050 0 1 0 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 3 1 2 Ton A C Cooling 1225 0 1 0 1170 1190 1205 1220 1225 1225 1225 1225 1225 1225 4...

Страница 11: ...nt 2 Pipe Only All Model Sizes 1Ú2 OD INDUCER HOUSING DRAIN CONNECTION 1Ú4 OD COLLECTOR BOX TO TRAP RELIEF PORT 5Ú8 OD COLLECTOR BOX DRAIN CONNECTION 1Ú2 IN PVC OR CPVC SCREW HOLE FOR UPFLOW OR DOWN FLOW APPLICATIONS OPTIONAL 1 4 2 7 8 1 8 7 SLOT FOR SCREW HORIZONTAL APPLICATION OPTIONAL WIRE TIE GUIDES WHEN USED 1 2 1 3 4 1 3 4 FRONT VIEW SIDE VIEW FURNACE DOOR FURNACE DOOR CONDENSATE TRAP 78 1 4...

Страница 12: ...OTES 1 Minimum return air openings at furnace based on metal duct If flex duct is used see flex duct manufacturer s recommendations for equivalent diameters 2 Minimum return air opening at furnace a For 800 CFM 16 in round or 14 1 2 x 12 in rectangle b For 1200 CFM 20 in round or 14 1 2 x 19 1 2 in rectangle c For 1600 CFM 22 in round or 14 1 2 x 23 1 4 in rectangle d For airflow requirements abov...

Страница 13: ...82 6 23 3 4 603 3 20 3 8 517 5 1 The plenum should be constructed 1 4 in smaller in width and depth than the plenum dimensions shown above A97427 Assembled A88207 Disassembled LOCATING TAB LOCATING TAB 1 2 3 4 4 3 2 1 B D C A 1 1 4 TYP PLENUM OPENING FACTORY SUPPLIED FIELD INSTALLED INSULATION Downflow Subbase A 23 5 8 23 3 8 Furnace Side 23 3 4 Centerline Screw Slots 25 5 8 Duct Side 24 3 8 Openi...

Страница 14: ...r maximum 2 voltage drop Time delay type is recommended 115 VOLT FIELD SUPPLIED FUSED DISCONNECT JUNCTION BOX CONTROL BOX 24 VOLT TERMINAL BLOCK THREE WIRE HEATING ONLY FIVE WIRE NOTE 2 NOTE 1 1 STAGE THERMOSTAT TERMINALS FIELD SUPPLIED FUSED DISCONNECT CONDENSING UNIT FURNACE COM R W C Y R G GND GND FIELD 24 VOLT WIRING FIELD 115 208 230 460 VOLT WIRING FACTORY 24 VOLT WIRING FACTORY 115 VOLT WIR...

Страница 15: ...centric 1 1 2 42 12 8 37 11 2 32 9 8 27 8 2 22 6 7 17 5 2 2 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 80 000 2 Pipe or 2 In Concentric 1 1 2 25 7 6 20 6 1 15 4 6 10 3 0 5 1 5 NA 2 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 100 000 2 Pipe or 2 In Concentric 2 38 11 6 33 10 1 28 8 5 23 7 0 18 5 5 13 4 0 2 1 2 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 120 000 2 Pipe or 3 In Concentri...

Страница 16: ...51 15 5 46 14 0 41 12 5 100 000 2 Pipe or 2 In Concentric 2 24 7 3 19 5 8 14 4 3 9 2 7 NA NA 2 1 2 57 17 4 55 16 8 53 16 2 51 15 5 49 14 9 47 14 3 120 000 2 Pipe or 3 In Concentric 3 one disk 39 11 9 37 11 3 35 10 7 33 10 1 31 9 5 29 8 8 Disk usage Unless otherwise stated use perforated disk assembly factory supplied in loose parts bag Wide radius elbow Vent sizing for Canadian installations over ...

Страница 17: ...140 taille sont pour altitudes comprises entre 0 2 135m 0 7 000 pi Utiliser une trousse de conversion fournie par le fabricant pour passer au gaz propane ou pour certaines installations au gaznaturel Cette fournaise à air pulsé est pour installation à l intérieur dans un bâtiment construit sur place Cette fournaise à air pulsé peut être installée dans une maison préfabriquée maison mobile si presc...

Страница 18: ...ER GAS FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW FRONT OF FURNACE A06511 Upflow Application ELECTRONIC AIR CLEANER HUMIDIFIER A C COIL VENT COMBUSTION AIR DIRECT VENT 2 PIPE APPLICATION OUTDOOR UNIT AIRFLOW FRONT OF FURNACE A07799 Downflow Application 58MVC ...

Страница 19: ...PIPE APPLICATION OPTIONAL VENTILATED COMBUSTION AIR APPLICATION A07800 Attic Horizontal Application COMBUSTION AIR PIPE DIRECT VENT 2 PIPE APPLICATION VENT PIPE ELECTRONIC AIR CLEANER FURNACE CONDENSATE DRAIN AIRFLOW AIR CONDITIONING COIL REFRIGERATION PIPING FRONT OF FURNACE OPTIONAL VENTILATED COMBUSTION AIR INTAKE A07801 Crawlspace Horizontal Application 58MVC ...

Страница 20: ...vibration transmission Primary Heat Exchangers Primary heat exchangers shall be 3 Pass 20 gauge corrosion resistant aluminized steel of fold and crimp sectional design and applied operating under negative pressure Secondary Heat Exchangers Secondary heat exchangers shall be of a flow through design having a patented interior laminate coating of polypropylene for greater corrosion resistance with f...

Отзывы: