Clearance in inches 
Dégagement (po).

Vent clearance to

combustibles 0".

0 (po) Dégagement

d´évent avec combustibles.

This furnace is approved for UPFLOW, DOWNFLOW and 
HORIZONTAL installations.

Cette fournaise est approuvée pour l´installation HORIZONTALE 
et la circulation d´air VERS LE HAUT et VERS LE BAS.

*

BOT

T

OM

DE

S

S

O

U

S

0"

Ø

3"

0"

§

0"

TO

P

/P

L

E

N

U

M

D

E

SSU

S

/C

H

A

MBR

E

 D´

AI

R

1"

0"

§

30

MIN

ALL POSITIONS:

S I

D E

C

O T

E S

F

R

O

N

T

A

V

A

N

T

B

C

K

A

R

R I

E

A

E

R

S

E

R V

I

E

C

L È

NT

R

T

E

N

E

I

V

A

N

A

T

F R

ON

T

S I

D E

C

O T

E S

F O

U

U

F

R N

A C

S

E

E

I

A

R N

Les fléches de dégagement 

ne change pas avec 

l´orientation de la 

générateur d´air chaud.

Clearance arrows 
do not change with 
furnace orientation.

MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION

POUR LA POSITION HORIZONTALE:

POUR LA POSITION COURANT DESCENDANT:

POUR TOUS LES POSITIONS:

HORIZONTAL POSITIONS:

DOWNFLOW POSITIONS:

§

Ø

*

Dégagement avant minimum de 762mm (30 po) pour l´entretien.

§

Ø

*

Mimimum front clearance for service 30 inches (762mm).

This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft (0 - 3,050m), except 140 size furnaces are only approved for altitudes 0 - 7,000 ft. 

(0 - 2,135m).
An accessory kit, supplied by the manufacturer, shall be used to convert to propane gas use or may be required for some natural gas applications.
This furnace is for indoor installation in a building constructed on site. This furnace may be installed in a manufactured (mobile) home when stated on rating plate and 
using factory authorized kit. 
This furnace may be installed on combustible flooring in alcove or closet at 

Minimum Inches Clearance  To Combustible Construction

 as described below. 

This furnace requires a special venting system. Refer to the installation instructions for parts list and method of installation. This furnace is for use with schedule-40 PVC, 
PVC-DWV, CPVC,  or  ABS-DWV pipe, and must not be vented in common with other gas-fired appliances. Construction through which vent/air intake pipes may be 
installed is maximum 24 inches (600 mm), minimum 3/4 inches (19 mm) thickness (including roofing materials).

UPFLOW OR
DOWNFLOW

1/2" MAX

FRONT

FRONT

LEVEL (0")TO

INSTALLATION

For upflow and downflow applications, furnace must be installed level, or pitched within 1/2" of level.  For a 
horizontal application, the furnace must be pitched minimum 1/4" to maximum of 1/2" forward for proper 
drainage.  See Installation Manual for IMPORTANT unit support details on horizontal applications.

HORIZONTAL

Cette fournaise à air pulsé est équipée pour utilisation avec gaz naturel et altitudes comprises entre 0 - 3,050m (0-10,000 pi), excepté queles fournaises de 140 taille 
sont pour altitudes comprises entre 0 - 2,135m (0 - 7,000 pi).
Utiliser une trousse de conversion, fournie par le fabricant, pour passer au gaz propane ou pour certaines installations au gaz naturel.
Cette fournaise à air pulsé est pour installation à l´intérieur dans un bâtiment construit sur place. Cette fournaise à air pulsé peut être installée dans une maison 
préfabriquée (maison mobile) si prescrit par la plaque signalétique et si l´on utilise une trousse specifiée par le fabricant. 
Cette fournaise peut être installée sur un plancher combustible dans un enfoncement ou un placard en observant les 

Dégagement Minimum En Pouces Avec 

Éléments De Construction Combustibles. 

Cette fournaise nécessite un système d´évacuation spécial. La méthode d´installation et la liste des pièces nécessaires figurent dans les instructions d´installation.  Cette 
fournaise doit s´utiliser avec la tuyauterie des nomenclatures 40 PVC, PVC-DWV, CPVC,  ou  ABS-DWV et elle ne peut pas être ventilée conjointment avec d´autres 
appareils à gaz. Épaisseur de la construction au travers de laquelle il est possible de faire passer les tuyaux d´aération (admission/évacuation): 24 po (600 mm) 
maximum, 3/4 po (19 mm) minimum (y compris la toiture).

Pour des applications de flux ascendant et descendant, la fournaise doit être installée de niveau ou inclinée à 
pas plus de 1/2" du niveau.  Pour une application horizontale, la fournaise doit être inclinée entre minimum 
1/4" et maximum 1/2" du niveau pour le drainage approprié.  En cas d'installation en position horizontale, 
consulter les renseignements IMPORTANTS sur le support dans le manuel d'installation.

MIN 1/4" TO 1/2" MAX

For installation on combustible floors only when installed on special base No. 
KGASB0201ALL, Coil Assembly, Part No. CD5 or CK5, or Coil Casing, Part No. KCAKC.

Line contact is permissible only between lines formed by intersections of top and two sides 
of furnace jacket, and building joists, studs, or framing.
Clearance shown is for air inlet and air outlet ends.
120  size furnace requires 1 inch bottom clearance to combustible materials.

Pour l´installation sur le plancher combustible seulement quand on utilise la base spéciale, 
pièce n°  KGASB0201ALL,  l´ensemble serpentin, pièce n°  CD5 ou CK5, ou le carter de 
serpentin, pièce n°  KCAKC.

Le contact n´est permis qúentre les lignes formées par les intersections du dessus et des 
deuxcôtés de la chemise de la fournaise, et des solives, des montants ou de la charpente 
du bátiment.
La distance indiquée concerne l´extrémité du tuyau d´arrivée d´air et l´extrémité du tuyau 
de sortie d´air.
Pour les fournaises de 120  taille, 1 po (25mm) dégagement des matériaux combustibles 
est requis au-dessous.

DÉGAGEMENT MINIMUM EN POUCES AVEC ÉLÉMENTS DE 

CONSTRUCTION COMBUSTIBLES 

328068-201 Rev. A

A07823

Clearance to Combustibles

58MV

C

Содержание INFINITY ICS 58MVC

Страница 1: ...ltration Quality materials are the key behind the Infinityt ICS s outstanding performance Carrier stands behind quality We offer lifetime warranty protection on the heat exchangers the heart of the Infinityt ICS The rest of the furnace is backed by a limited 5 year warranty The Infinityt ICS is available in 5 heat airflow combinations The unit has a 4 way multipoise design and can be installed in ...

Страница 2: ...enter The microprocessor control center features state of the art combustion temperature and airflow control to maximize comfort while operating at peak efficiency Combustion control is obtained by taking the inducer motor RPM reading when the medium heat pressure switch makes Using this information the microprocessor maintains a consistent air to fuel ratio independent of vent sizing and conditio...

Страница 3: ...s for disposal into home drain system Location in furnace varies 10 Heavy duty blower Circulates air across the heat exchangers to transfer heat into the home 11 Serpentufft secondary condensing heat exchanger inside Wrings out more heat through condensation Constructed with polypropylene laminated steel to ensure durability 12 Primary serpentine heat exchanger inside Stretches fuel dollars with t...

Страница 4: ...ensate Neutralizer Kit obtained thru RCD P908 0001 X X X X X Electronic Air Cleaner Model EACB X X X X X Mechanical Air Cleaner Model FILCAB or EZXCAB X X X X X Humidifier Model HUM X X X X X Heat Recovery Ventilator Model HRV X X X X X Energy Recovery Ventilator Model ERV X X X X X UV Lights Model UVL X X X X X EZ Flex Media Filter with end caps 16 in 9 pack EXPXXLMC0016 X EZ Flex Media Filter wi...

Страница 5: ...22 X X X Gas Orifice Kit Size 42 Qty 50 KGAHA0150N42 See Installation Instructions for model altitude and heat value usages Gas Orifice Kit Size 43 Qty 50 KGAHA0250N43 Gas Orifice Kit Size 44 Qty 50 KGAHA0350N44 Gas Orifice Kit Size 45 Qty 50 KGAHA0450N45 Gas Orifice Kit Size 46 Qty 50 KGAHA0550N46 Gas Orifice Kit Size 47 Qty 50 KGAHA1550N47 Gas Orifice Kit Size 48 Qty 50 KGAHA850N48 Gas Orifice K...

Страница 6: ...r Conditioner _F _C Auto Changeover 5 2 Programmable TSTATCCPDF01 B For use with multi stage applications _F _C Auto Changeover 7 Day Programmable TSTATCCPRH01 B For multi use stage configurations _F _C Auto Changeover 7 Day Programmable SYSTXCCUID01 B Infinityt user interface Model HP 2 Stage thermostat must be field converted to air conditioner operation Hybrid Heat thermostat is used with furna...

Страница 7: ...BER MEDIUM HEAT ADJUSTMENT UNDER CAP INLET PRESSURE TAP ON OFF SWITCH HIGH HEAT ADJUSTMENT UNDER CAP BURNER ENCLOSURE REFFERENCE TAP LOW HEAT ADJUSTMENT UNDER CAP MANIFOLD PRESSURE TAP A07422 A92505 A07280 CONTROL CENTER HEAT EXCHANGERS GAS VALVE ______________________________________________________________________________________________________________ Concentric Vent Kit A93086 A concentric ve...

Страница 8: ...d through a series of electronic dampers and remote rooom sensors The 4 zone system is shown ENERGY HEAT RECOVERY VENTILATOR Carrier s energy or heat recovery ventilators exhaust stale indoor air and provide fresh outdoor air to the home while minimizing heat loss and humidity level Especially useful for today s tighter constructed houses Energy recovery ventilator is shown _______________________...

Страница 9: ...5 625 695 800 685 790 875 1005 1095 1260 Heating High 1070 1220 1470 1510 1900 Cooling Max 1400 1375 1975 1950 2060 OUTPUT CAPACITY BTUH ICS Low Upflow 22000 30000 30000 38000 46000 Downflow 23000 30000 30000 38000 46000 Horizontal 21000 30000 30000 38000 45000 Medium Upflow 37000 49000 49000 61000 73000 Downflow 36000 49000 49000 61000 73000 Horizontal 36000 49000 49000 61000 73000 High Upflow 56...

Страница 10: ... 660 660 655 655 655 Medium Heat 890 0 0 50 875 890 890 890 890 High Heat 1510 0 1 0 1510 1510 1510 1510 1510 1500 1490 1480 1470 1455 2 Ton A C Cooling 700 0 0 50 700 690 690 690 690 2 1 2 Ton A C Cooling 875 0 0 50 835 845 855 860 865 3 Ton A C Cooling 1050 0 1 0 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 3 1 2 Ton A C Cooling 1225 0 1 0 1170 1190 1205 1220 1225 1225 1225 1225 1225 1225 4...

Страница 11: ...nt 2 Pipe Only All Model Sizes 1Ú2 OD INDUCER HOUSING DRAIN CONNECTION 1Ú4 OD COLLECTOR BOX TO TRAP RELIEF PORT 5Ú8 OD COLLECTOR BOX DRAIN CONNECTION 1Ú2 IN PVC OR CPVC SCREW HOLE FOR UPFLOW OR DOWN FLOW APPLICATIONS OPTIONAL 1 4 2 7 8 1 8 7 SLOT FOR SCREW HORIZONTAL APPLICATION OPTIONAL WIRE TIE GUIDES WHEN USED 1 2 1 3 4 1 3 4 FRONT VIEW SIDE VIEW FURNACE DOOR FURNACE DOOR CONDENSATE TRAP 78 1 4...

Страница 12: ...OTES 1 Minimum return air openings at furnace based on metal duct If flex duct is used see flex duct manufacturer s recommendations for equivalent diameters 2 Minimum return air opening at furnace a For 800 CFM 16 in round or 14 1 2 x 12 in rectangle b For 1200 CFM 20 in round or 14 1 2 x 19 1 2 in rectangle c For 1600 CFM 22 in round or 14 1 2 x 23 1 4 in rectangle d For airflow requirements abov...

Страница 13: ...82 6 23 3 4 603 3 20 3 8 517 5 1 The plenum should be constructed 1 4 in smaller in width and depth than the plenum dimensions shown above A97427 Assembled A88207 Disassembled LOCATING TAB LOCATING TAB 1 2 3 4 4 3 2 1 B D C A 1 1 4 TYP PLENUM OPENING FACTORY SUPPLIED FIELD INSTALLED INSULATION Downflow Subbase A 23 5 8 23 3 8 Furnace Side 23 3 4 Centerline Screw Slots 25 5 8 Duct Side 24 3 8 Openi...

Страница 14: ...r maximum 2 voltage drop Time delay type is recommended 115 VOLT FIELD SUPPLIED FUSED DISCONNECT JUNCTION BOX CONTROL BOX 24 VOLT TERMINAL BLOCK THREE WIRE HEATING ONLY FIVE WIRE NOTE 2 NOTE 1 1 STAGE THERMOSTAT TERMINALS FIELD SUPPLIED FUSED DISCONNECT CONDENSING UNIT FURNACE COM R W C Y R G GND GND FIELD 24 VOLT WIRING FIELD 115 208 230 460 VOLT WIRING FACTORY 24 VOLT WIRING FACTORY 115 VOLT WIR...

Страница 15: ...centric 1 1 2 42 12 8 37 11 2 32 9 8 27 8 2 22 6 7 17 5 2 2 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 80 000 2 Pipe or 2 In Concentric 1 1 2 25 7 6 20 6 1 15 4 6 10 3 0 5 1 5 NA 2 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 100 000 2 Pipe or 2 In Concentric 2 38 11 6 33 10 1 28 8 5 23 7 0 18 5 5 13 4 0 2 1 2 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 120 000 2 Pipe or 3 In Concentri...

Страница 16: ...51 15 5 46 14 0 41 12 5 100 000 2 Pipe or 2 In Concentric 2 24 7 3 19 5 8 14 4 3 9 2 7 NA NA 2 1 2 57 17 4 55 16 8 53 16 2 51 15 5 49 14 9 47 14 3 120 000 2 Pipe or 3 In Concentric 3 one disk 39 11 9 37 11 3 35 10 7 33 10 1 31 9 5 29 8 8 Disk usage Unless otherwise stated use perforated disk assembly factory supplied in loose parts bag Wide radius elbow Vent sizing for Canadian installations over ...

Страница 17: ...140 taille sont pour altitudes comprises entre 0 2 135m 0 7 000 pi Utiliser une trousse de conversion fournie par le fabricant pour passer au gaz propane ou pour certaines installations au gaznaturel Cette fournaise à air pulsé est pour installation à l intérieur dans un bâtiment construit sur place Cette fournaise à air pulsé peut être installée dans une maison préfabriquée maison mobile si presc...

Страница 18: ...ER GAS FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW FRONT OF FURNACE A06511 Upflow Application ELECTRONIC AIR CLEANER HUMIDIFIER A C COIL VENT COMBUSTION AIR DIRECT VENT 2 PIPE APPLICATION OUTDOOR UNIT AIRFLOW FRONT OF FURNACE A07799 Downflow Application 58MVC ...

Страница 19: ...PIPE APPLICATION OPTIONAL VENTILATED COMBUSTION AIR APPLICATION A07800 Attic Horizontal Application COMBUSTION AIR PIPE DIRECT VENT 2 PIPE APPLICATION VENT PIPE ELECTRONIC AIR CLEANER FURNACE CONDENSATE DRAIN AIRFLOW AIR CONDITIONING COIL REFRIGERATION PIPING FRONT OF FURNACE OPTIONAL VENTILATED COMBUSTION AIR INTAKE A07801 Crawlspace Horizontal Application 58MVC ...

Страница 20: ...vibration transmission Primary Heat Exchangers Primary heat exchangers shall be 3 Pass 20 gauge corrosion resistant aluminized steel of fold and crimp sectional design and applied operating under negative pressure Secondary Heat Exchangers Secondary heat exchangers shall be of a flow through design having a patented interior laminate coating of polypropylene for greater corrosion resistance with f...

Отзывы: