background image

16

TYPICAL WIRING SCHEMATIC

115-VOLT FIELD-

SUPPLIED

FUSED

DISCONNECT   

JUNCTION

BOX   

CONTROL

BOX

24-VOLT

TERMINAL

BLOCK  

THREE-WIRE

HEATING-

ONLY   

FIVE

WIRE

   

NOTE 2

NOTE 1

1-STAGE

THERMOSTAT

TERMINALS

   

FIELD-SUPPLIED

FUSED DISCONNECT

CONDENSING

UNIT   

FURNACE

COM

R

 

W

C

Y

R

G

GND   

GND   

FIELD 24-VOLT WIRING

FIELD 115-, 208/230-, 460-VOLT WIRING

FACTORY 24-VOLT WIRING

FACTORY 115-VOLT WIRING   

Connect Y/Y2-terminal as shown for proper operation.

Some thermostats require a "C" terminal connection as shown.

If any of the original wire, as supplied, must be replaced, use

same type or equivalent wire.

208/230- OR

460-VOLT

THREE

PHASE   

208/230-

VOLT

SINGLE

PHASE   

WHT   

BLK   

WHT   

BLK   

A95236

W/W1

W2

Y/Y2

G

NOTES:

1.

2.

3.

A95236

58U

VB

Содержание Infinity 96 58UVB

Страница 1: ... pipe only The Infinity 96 is not approved for installation in mobile homes recreational vehicles or outdoor use The variable speed makes the Infinity 96 ideal for use with split system cooling including 2 stage units A Carrier electronic air cleaner humidifier Thermidistatt comfort ventilator and Comfort Zonet II will provide year round comfort and efficiency Designed for durability comfort and r...

Страница 2: ... The first cycle after power reset provides 16 minutes of low heat before switching to high heat unless the room thermostat has been satisfied Subsequent thermostat cycles provide anywhere from 0 to 16 minutes of low heat depending on the length of the previous thermostat cycle Airflow control is accomplished by using a technique involving the microprocessor and blower motor The static load on the...

Страница 3: ...ed polypropylene laminated steel to ensure durability 8 Pressure switches ensure adequate flow of flue products through furnace and out vent system 9 Inducer motor Pulls hot flue gases through the heat exchangers maintaining negative pressure for added safety 10 Condensate drain connection Collects moisture condensed during combustion process 11 Heavy duty blower Circulates air across the heat exc...

Страница 4: ...ronic Air Cleaner Model EACA X X X X X Mechanical Air Cleaner Model FILCAB or EZXCAB X X X X X Humidifier Model HUM X X X X X Heat Recovery Ventilator Model HRV X X X X X Energy Recovery Ventilator Model ERV X X X X X UV Lights Model UVL X X X X X EZ Flex Media Filter with end caps 16 in 9 pack EXPXXLMC0016 X EZ Flex Media Filter with end caps 20 in 9 pack EXPXXLMC0020 X X X EZ Flex Media Filter w...

Страница 5: ...20 X X X Gas Orifice Kit Size 42 Qty 50 KGAHA0150N42 See Installation Instructions for model altitude and heat value usages Gas Orifice Kit Size 43 Qty 50 KGAHA0250N43 Gas Orifice Kit Size 44 Qty 50 KGAHA0350N44 Gas Orifice Kit Size 45 Qty 50 KGAHA0450N45 Gas Orifice Kit Size 46 Qty 50 KGAHA0550N46 Gas Orifice Kit Size 47 Qty 50 KGAHA1550N47 Gas Orifice Kit Size 48 Qty 50 KGAHA850N48 Gas Orifice K...

Страница 6: ...itioner _F _C Auto Changeover 7 Day Programmable TSTATCCSAC01 For use with 1 speed Air Conditioner _F _C Auto Changeover 5 2 Programmable TSTATCCPDF01 B For use with multi stage applications _F _C Auto Changeover 7 Day Programmable TSTATCCPRH01 B For multi use stage configurations _F _C Auto Changeover 7 Day Programmable SYSTXCCUID01 A For multi use stage configurations _F _C Auto Changeover 7 Day...

Страница 7: ...Ð LOW VOLTAGE MAIN HARNESS CONNECTOR EAC 1 TERMINAL 115 VAC 1 0 AMP MAX 115 VAC L1 LINE VOLTAGE CONNECTIONS 115 VAC L2 NEUTRAL CONNECTIONS PL2 Ð HOT SURFACE IGNITER INDUCER MOTOR CONNECTOR 24 V THERMOSTAT TERMINALS FUTURE APPLICATIONS X A92505 Heat Exchangers A02278 Control Center A02286 Inducer Assembly A93086 Concentric Vent Direct Vent 2 Pipe Only A concentric vent kit allows vent and combustio...

Страница 8: ...2 Controls Thermostats and Zoning Available in programmable and non programmable models Carrier thermostats maintain a constant comfortable temperature level in the home For the ultimate in home comfort Carrier s 2 4 or 8 zone systems allow temperature control of individual zones of the home This is accomplished through a series of electronic dampers and remote room sensors The 4 zone system is sh...

Страница 9: ...IZE 060 14 080 14 080 20 100 20 120 20 Direct Drive Motor Hp ECM 1 2 1 2 1 1 1 Motor Full Load Amps 7 7 7 7 12 8 12 8 12 8 RPM Nominal Speeds Variable 250 1300 Blower Wheel Diameter X Width in 10 X 7 11 X 10 11 X 10 11 X 10 11 X 10 Filter Size in Nominal A Washable 1 16 X 25 X 1 1 20 X 25 X 1 1 20 X 25 X 1 1 20 X 25 X 1 1 24 X 25 X 1 Shipping Weight lb 170 182 204 203 234 Limit Control SPST Heatin...

Страница 10: ...00 75 000 75 000 94 000 113 000 AFUE 95 0 95 0 95 0 95 0 95 0 Input Btuh Low 39 000 52 000 52 000 65 000 78 000 High 60 000 80 000 80 000 100 000 120 000 Airflow shown is for bottom only return air supply with factory supplied 1 in washable filter s For air delivery above 1800 CFM see Air Delivery table for other options Low heat CFM when low heat rise adjustment switch SW1 3 on furnace control is...

Страница 11: ...0 1250 1200 1155 1 1 2 Ton A C Cooling 525 0 0 50 525 525 515 505 485 2 Ton A C Cooling 700 0 0 50 700 700 695 695 700 2 1 2 Ton A C Cooling 875 0 1 0 840 855 875 875 875 875 870 855 850 850 3 Ton A C Cooling 1050 0 1 0 1050 1050 1050 1050 1050 1050 1045 1045 1040 1030 3 1 2 Ton A C Cooling 1225 0 1 0 1225 1225 1225 1225 1225 1225 1225 1225 1225 1195 Maximum 1400 0 1 0 1400 1400 1400 1400 1395 135...

Страница 12: ... 50 700 700 700 700 695 2 1 2 Ton A C Cooling 875 0 0 50 875 875 875 870 870 3 Ton A C Cooling 1050 0 1 0 1035 1040 1050 1050 1050 1050 1050 1025 1005 1000 3 1 2 Ton A C Cooling 1225 0 1 0 1205 1210 1225 1225 1225 1225 1225 1225 1220 1215 4 Ton A C Cooling 1400 0 1 0 1390 1400 1400 1400 1400 1400 1395 1385 1370 1360 5 Ton A C Cooling 1750 0 1 0 1745 1740 1745 1745 1745 1745 1745 1740 1730 1715 6 T...

Страница 13: ...6 5 8 6 1 4 5 3 4 KGAVT0601CVT 38 7 8 3 4 1 2 21 1 8 7 3 8 6 1 2 Dimension A will change proportionally as dimension D is lengthened or shortened Dimension D may be lengthened to 60 in maximum Dimension D may also be shortened by cutting the pipes provided in the kit to 12 in minimum CONDENSATE TRAP CONDENSATE TRAP INSIDE BLOWER SHELF ALTERNATE DRAIN TUBE LOCATION UPFLOW APPLICATIONS CONDENSATE TR...

Страница 14: ...uct is used see flex duct manufacturer s recommendations for equivalent diameters 2 Minimum return air opening at furnace a For 800 CFM 16 in round or 14 1 2 x 12 in rectangle b For 1200 CFM 20 in round or 14 1 2 x 19 1 2 in rectangle c For 1600 CFM 22 in round or 14 1 2 x 23 1 4 in rectangle d For airflow requirements above 1800 CFM see Air Delivery table in Product Data literature for specific u...

Страница 15: ...0 Unit Volts Hertz Phase 115 60 1 Operating Voltage Range Min Max 104 127 Maximum Unit Amps 8 9 8 9 13 8 13 8 13 8 Minimum Wire Size 14 14 12 12 12 Maxium Wire Length ft 31 31 32 32 32 Maximum Fuse or Ckt Brk Amps 15 15 20 20 20 Transformer 24v 40va External Control Power Available Heating 25va Cooling 34va Permissible limits of the voltage range at which the unit will operate satisfactorily Lengt...

Страница 16: ...CE COM R W C Y R G GND GND FIELD 24 VOLT WIRING FIELD 115 208 230 460 VOLT WIRING FACTORY 24 VOLT WIRING FACTORY 115 VOLT WIRING Connect Y Y2 terminal as shown for proper operation Some thermostats require a C terminal connection as shown If any of the original wire as supplied must be replaced use same type or equivalent wire 208 230 OR 460 VOLT THREE PHASE 208 230 VOLT SINGLE PHASE WHT BLK WHT B...

Страница 17: ...TION TYPE PIPE DIA IN NUMBER OF 90_ ELBOWS 1 2 3 4 5 6 3001 to 4000 60 000 2 Pipe or 2 in Concentric 1 1 2 42 37 32 27 22 17 2 70 70 70 70 70 70 80 000 2 Pipe or 2 in Concentric 1 1 2 25 20 15 10 5 N A 2 70 70 70 70 70 70 100 000 2 Pipe or 2 in Concentric 2 38 33 28 23 18 13 2 1 2 70 70 70 70 70 70 120 000 2 Pipe or 3 in Concentric 3 one disk 29 24 10 N A N A N A 3 one disk 59 59 58 57 57 56 ALTIT...

Страница 18: ...1 2 62 60 58 56 55 53 120 000 2 Pipe or 3 in Concentric 3 one disk 43 41 39 37 35 34 ALTITUDE UNIT SIZE BTUH TERMINATION TYPE PIPE DIA IN NUMBER OF 90_ ELBOWS 1 2 3 4 5 6 9001 to 10000 60 000 2 Pipe or 2 in Concentric 1 1 2 27 22 17 12 7 N A 2 57 55 53 51 49 47 80 000 2 Pipe or 2 in Concentric 1 1 2 15 10 5 N A N A N A 2 57 55 53 51 46 41 100 000 2 Pipe or 2 in Concentric 2 24 19 14 9 N A N A 2 1 ...

Страница 19: ... 70 70 70 0 2 20 39 45 55 63 20 2 11 27 31 39 45 100 20 20 2 1 2 41 70 70 70 70 0 2 1 2 21 42 48 59 68 20 2 1 2 11 28 33 41 49 120 20 20 3 49 70 70 70 70 0 3 26 51 58 70 70 20 3 15 35 40 50 59 Pipe length ft specified for maximum vent pipe lengths located in unconditioned spaces Vent pipes located in unconditioned space cannot exceed the total allowable pipe length as specified in the Maximum Allo...

Страница 20: ...cted on site This furnace may be installed in a manufactured mobile home when stated on rating plate and using factory authorized kit This furnace may be installed on combustible flooring in alcove or closet at Minimum Inches Clearance To Combustible Construction as described below This furnace requires a special venting system Refer to the installation instructions for parts list and method of in...

Страница 21: ...21 TYPICAL INSTALLATIONS COMBUSTION AIR PIPE A C COIL OUTDOOR UNIT VENT PIPE HUMIDIFIER GAS FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW FRONT OF FURNACE A06511 58UVB ...

Страница 22: ...educe vibration transmission Primary Heat Exchangers Primary heat exchangers shall be 3 Pass 20 gauge corrosion resistant aluminized steel of fold and crimp sectional design and applied operating under negative pressure Secondary Heat Exchangers Secondary heat exchangers shall be of a flow through design having a patented interior laminate coating of polypropylene for greater corrosion resistance ...