Document revision history
MPC Open XP
MPC Open XP IO48/816
Carrier Proprietary and Confidential
CARRIER CORPORATION ©2017
Installation and Start-up Guide
All rights reserved
43
Important changes to this document are listed below. Minor changes such as typographical or formatting errors are not
listed.
Date
Topic
Change description
Code*
6/20/17
Appendix A: MPC Open XP wire lists
Caution added to not use 39m library applications with the MPC
Open XP.
C-TS-CP-E-WB
2/23/17
Changed sensor and adapter name from WS to wireless.
C-D
1/18/17
Wireless sensor overview
To install the Wireless Adapter for
Wireless sensors
New topics
C-D
Wiring devices to the MPC Open XP's
Rnet port
Updated format and added Wireless Adapter for Wireless sensors C-D
Input wiring specifications
Added Wireless Adapter for Wireless sensors
C-D
To wire the controller to the network
Added BACnet ARC156 connection information.
C-D
Wiring for communications
Changed from Wiring the MPC Open XP to the MS/TP network
C-D
Specifications
Added BACnet ARC156 and updated Rnet port information to
include Wireless Adapter.
C-D
Cover
What are the MPC Open XP and MPC
Open XP expanders?
Changed MPC Open XP to new silkscreen
C-D
2/19/16
Local access to the MPC Open XP
Added USB Link wiring caution.
C-TS-RD-E-JH
2/9/16
To attach the MPC Open XPIO expander Added step explaining jumper settings for connecting more than
one expander.
X-TS-RD-E-BR
12/3/15
Replacing the battery
Corrected instructions from the wrong battery to the correct one.
X-D
11/18/14 MPC Open XPIO48 and MPC Open
XPIO816
Power rating corrected from 45VA to 40VA, as listed on the
silkscreen
C-D-LJ-O-BR
8/14/14
MPC Open XP specifications
Maximum number of BACnet third-party integration points using
Snap - changed to unlimited, depending on memory
Power - removed references to BACview
Rnet port - added Equipment Touch and removed BACview
Rnet port - added note that number of possible ZS sensors you
can have with an Equipment Touch is 15
Local Access port - removed BACview, added Equipment Touch
Battery - added Equipment Touch and removed BACview
C-D-LJ-O
Wiring devices to the Rnet port
Changed from "Wiring a communicating zone sensor to the MPC
Open XP"
Removed references to BACview
Connecting an SPT sensor
Removed BACview and added Equipment Touch
To wire an Equipment Touch to the
MPC Open XP
New topic
BACview devices
Removed references and topics
Local Access to the MPC Open XP
Removed BACview and added Equipment Touch
To wire the Equipment Touch to the
MPC Open XP
Added Caution to maintain polarity and use the power supply only
for Carrier controllers
C-TS-RD-E
Restore factory defaults
Corrected from using a jumper to holding the Format button
C-D-LJ
* For internal use only
Document revision history