March 2021
Page 66 of 143
59812-K007 Rev 17
Business Confidential
Use the Up and Down arrows to scroll through the events in this screen.
Figure 94
Event Log by Detector
screen, Figure 85.
3.7
DETECTOR SCREEN USER
In addition to information relating to the engine information can also be displayed for the individual
detectors.
Status information on a single engine can be accessed by pressing the required detector button under
the bar graph.
Figure 95
Detector Status Screen - User
The status screen shows:
Peak Level
The highest oil mist level indicated by the detector since the peak level
was reset.
Alarm Level
The slowdown/shutdown alarm level set for the detector.
Pre-Alarm Level
The pre-alarm level set for the detector.
Isolated
Indicates Yes if the detector is isolated.
Comms Fault
Indicates Yes if the detector is not communicating with the Control Unit.
Fan Fault
Indicates Yes if the fan has failed on the detector.
LED Fault
Indicates Yes if there is oil contamination in the sample chamber.
Photodiode Fault
Indicates Yes if light is failing to reach the measuring photodiode
Watchdog Fault
Indicates Yes if a detector software failure has caused the detector to be
automatically reset.
Memory Fault
Indicates Yes if a fault has been detected in the Control Unit memory
Содержание Graviner Mk7
Страница 26: ...March 2021 Page 15 of 143 59812 K007 Rev 17 Business Confidential Figure 10 Detector Head Installation ...
Страница 42: ...March 2021 Page 31 of 143 59812 K007 Rev 17 Business Confidential Figure 29 Wiring Drawing ...
Страница 129: ...March 2021 Page 118 of 143 59812 K007 Rev 17 Business Confidential 6 6 1 CONTROL UNIT Figure 182 Control Unit Spares ...
Страница 149: ...March 2021 Page 138 of 143 59812 K007 Rev 17 Business Confidential ...
Страница 152: ...March 2021 Page 141 of 143 59812 K007 Rev 17 Business Confidential ...