FX4D: Installation Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
4
A03001
Fig. 5 – Conversion for Horizontal Right Applications - Slope Coil
A00071A
Fig. 6 – Conversion for Horizontal Right Applications - A-Coil
A07571
Fig. 7 – Drain Pan Support Bracket
MANUFACTURED HOUSING AND MOBILE HOME
APPLICATIONS
1. Fan coil unit must be secured to the structure using field-supplied
hardware.
2. Allow a minimum of 24 inches (610mm) clearance from access
panels.
3. Recommended method of securing for typical applications:
a. If fan coil is away from wall, attach pipe strap to top of fan coil
using No. 10 self tapping screws. Angle strap down and away
from back of fan coil, remove all slack, and fasten to wall stud of
structure using 5/16” lag screws. Typically both sides of the fan
coil.
b. If fan coil is against wall, secure fan coil to wall stud using 1/8”
(3mm) wide right-angle brackets. Attach brackets to fan coil
using No. 10 self tapping screws and to wall stud using 5/16” lag
screws (refer to Fig. 8).
COIL MOUNTING
SCREW
BLOWER
ASSEMBLY
REFRIGERANT
CONNECTIONS
SECONDARY DRAIN
PRIMARY DRAIN
DRAINPAN
SLOPE COIL
SKI
COIL
SUPPORT
RAIL
COIL
SUPPORT
RAIL
COIL
BRACKET
DRAIN PAN
SUPPORT
BRACKET
COIL
SUPPORT
RAIL
COIL
BRACKET
HORIZONTAL
DRAIN PAN
PRIMARY DRAIN
HORIZONTAL RIGHT
SECONDARY DRAIN
HORIZONTAL RIGHT
REFRIGERANT
CONNECTIONS
AIR SEAL
ASSEMBLY
A
B
C
HORIZONTAL
RIGHT
APPLICATION
DRAIN PAN
SUPPORT BRACKET