Table 5 – FV4C Airflow Delivery (CFM)

FAN

UNIT

SIZE

OUTDOOR

UNIT

CAPACITY

BTUH

ELECTRIC HEATER kW RANGE

0---5

0---10

0---15

0---20

Lo

Nom

High

Lo

Nom

High

Lo

Nom

High

Lo

Nom

High

002

18,000

625

625

625

675

675

---

---

---

---

---

---

---

24,000

650

725

835

---

725

835

875

875

875

---

---

---

30,000

815

905

1040

---

905

1040

900

900

1040

1100

1100

1100

36,000

980

1085

1250

980

1085

1250

980

1085

1250

1100

1100

1250

003

24,000

675

725

835

875

875

---

---

---

---

---

---

---

30,000

815

905

1040

875

905

1040

1100

1100

1100

---

---

---

36,000

980

1085

1250

980

1085

1250

1100

1100

1250

1225

1225

1250

42,000

1140

1270

1460

1140

1270

1460

1140

1270

1460

1225

1270

1460

FAN

UNIT

SIZE

OUTDOOR

UNIT

CAPACITY

BTUH

ELECTRIC HEATER kW RANGE

0---10

0---15

0---20

0---30

Lo

Nom

High

Lo

Nom

High

Lo

Nom

High

Lo

Nom

High

005

30,000

975

975

1040

1100

1100

1100

---

---

---

---

---

---

36,000

980

1085

1250

1100

1100

1250

1250

1250

1250

---

---

---

42,000

1140

1270

1460

1140

1270

1460

1250

1270

1460

---

---

---

48,000

1305

1450

1665

1305

1450

1665

1305

1450

1665

1500

1500

1665

006

36,000

1100

1100

1250

1350

1350

1350

---

---

---

---

---

---

42,000

1140

1270

1460

1350

1350

1460

1525

1525

1525

---

---

---

48,000

1305

1450

1665

1350

1450

1665

1525

1525

1665

1750

1750

1750

60,000

1630

1810

2085

1630

1810

2085

1630

1810

2085

1750

1810

2085

NOTE

: Lo, NOM, and HI refer to AC, HP CFM ADJUST selection.

--- Airflow not recommended for heater/system size.

Table 6 – FV4C Minimum CFM for Electric Heater Application

FAN COIL UNIT

HEAT PUMP

UNIT SIZE

CFM

HEATER SIZE kW

5

8, 9, 10

15

18, 20

24, 30

002

Heater Only

625

625

725

875

018

625

625

024

650

725

875

030

800

875

875

1040

036

970

970

970

1040

003

Heater Only

675

700

1050

1050

024

675

875

030

800

875

1100

036

975

975

1100

1225

042

1125

1125

1125

1225

005

Heater Only

675

700

1050

1050

1400

018

800

875

1100

036

975

975

1100

1225

042

1125

1125

1125

1225

048

1305

1305

1305

1305

1400

006

Heater Only

1050

1050

1050

1050

1750

018

1100

1100

1350

1350

042

1125

1125

1350

1350

048

1300

1300

1350

1465

1750

060

1625

1625

1625

1750

1750

NOTES

:

1. Heater Only---Air conditioner with electric heater application.
2. These airflows are minimum acceptable airflows as UL listed. Actual airflow delivered will be per airflow deliver chart for Electric Heating Modes.

FV4

C

 

 

 

Содержание FV4C

Страница 1: ...70 In Canada refer to the current editions of the Canadian Electrical Code CSA C22 1 Recognize safety information When you see this symbol on the unit and in instructions or manuals be alert to the p...

Страница 2: ...ng and or living area building codes may require a field supplied secondary condensate pan to be installed under the entire unit Some localities may allow the alternative of running a separate seconda...

Страница 3: ...DRAIN 1 3 4 44 mm FILTER ACCESS CLEARANCE A09323 Fig 3 Slope Coil in Horizontal Left Application Factory Ready A B C FACTOR Y SHIPPED HORIZONTAL LEFT APPLICATION AIR SEAL ASSEMBLY HORIZONTAL DRAIN PA...

Страница 4: ...ting metal support straps See Fig 4 D Horizontal Right Conversion of Units with Slope Coils PROPERTY DAMAGE HAZARD Failure to follow this caution may result in property damage Gasket kit number KFAHD0...

Страница 5: ...n knockouts on right side of coil access panel 12 Remove 2 oval coil access panel plugs and reinstall into holes on left side of coil access panel and fitting panel 13 Install condensate pan fitting c...

Страница 6: ...ctric heater is installed use heat resistant material for flexible connector between ductwork and unit at discharge connection Ductwork passing through unconditioned space must be insulated and covere...

Страница 7: ...e heater operation When additional heater staging is desired using outdoor thermostats or Intelligent Heat Staging remove Jumper J2 on PCB to enable staging Connect low voltage leads to thermostat and...

Страница 8: ...pump defrost cycle A corporate thermostat in conjunction with an outdoor sensor can be used to lock out supplemental heat above 40_F 4_C Refer to thermostat instructions for details If a non corporate...

Страница 9: ...See Fig 14 and 16 Factory approved condensate traps are available Be sure to install plastic push in plugs in unused condensate drain fittings It is recommended that PVC fittings be used on the plast...

Страница 10: ...STEM TYPE AC HP CFM ADJUST ON OFF DELAY CONTINUOUS FAN MED HI YEL LO AUX1 HUM1 AUX2 24VAC GRY HUM2 YEL WHT BLK ORN BLU VIO 0 15 875 0 10 675 0 90 30 90 0 0 0 5 625 TM A B C D E F KW CFM LOW VOLTAGE TE...

Страница 11: ...connector to MED 80 cooling mode airflow 3 HI speed move connector of HI 100 cooling mode air flow See Fig 17 F as indicated G Low Voltage Circuit Fusing and Reference The low voltage circuit is fuse...

Страница 12: ...y falls to a level which causes the humidistat to close its contacts When the contacts close the airflow will return to 100 of the selected cooling airflow To activate this mode remove Jumper J1 and w...

Страница 13: ...ltage present at each pin on 12 pin plug PL 1 See Table 7 for pin number on 16 pin plug which should have voltage when Easy Select Board screw terminals have 24vac C Use following procedure to check c...

Страница 14: ...ns is within sight from and is readily accessible from the unit Disconnect all electrical power to unit before performing any maintenance or service on it WARNING The minimum maintenance requirements...

Страница 15: ...volts and with 10KW heater and filter installed 4 Airflows shown are at standard air conditions Table 4 FV4C Fan Coil Airflow Delivery CFM in Heat Pump Only Heating Mode OPERATING MODE UNIT SIZE OUTD...

Страница 16: ...0 1350 1350 42 000 1140 1270 1460 1350 1350 1460 1525 1525 1525 48 000 1305 1450 1665 1350 1450 1665 1525 1525 1665 1750 1750 1750 60 000 1630 1810 2085 1630 1810 2085 1630 1810 2085 1750 1810 2085 NO...

Страница 17: ...be 400 psig DOT 4BA400 or DOT BW400 S Puron systems should be charged with liquid refrigerant Use a commercial type metering device in the manifold hose when charging into suction line with compresso...

Страница 18: ...W Morris St D Indianapolis IN 46231 Printed in U S A Edition Date 05 09 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog...

Отзывы: