Installation Instructions

NOTE: 

Read the entire instruction manual before starting the installation.

Table of Contents

Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Safety Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Airflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

TXV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Cabinet Sweating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Inspect Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Select Installation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Installation of Evaporator Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Refrigerant Line Connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Connect Refrigerant, Liquid, and Suction Lines . . . . . . . . . . . . . . 5

Waste Line Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Humidifier Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Care and Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Safety Considerations

Improper  installation,  adjustment,  alteration,  service,  maintenance,  or

use can cause explosion, fire, electrical shock, or other conditions which

may  cause  death,  personal  injury  or  property  damage.  Consult  a

qualified  installer,  service  agency,  or  your  distributor  or  branch  for

information  or  assistance.  The  qualified  installer  or  agency  must  use

factory-authorized  kits  or  accessories  when  modifying  this  product.

Refer to the individual instructions packaged with the kits or accessories

when installing.
Follow  all  safety  codes. Wear  safety  glasses,  protective  clothing,  and

work  gloves.  Use  quenching  cloth  for  brazing  operations.  Have  fire

extinguisher available. Read these instructions thoroughly and follow all

warning  or  cautions  included  in  literature  and  attached  to  the  unit.

Consult  local  building  codes  and  the  current  editions  of  the  National

Electrical Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical Code

CSA C22.1.
Recognize safety information. When you see this symbol   on the unit

and  in  instructions  or  manuals,  be  alert  to  the  potential  for  personal

injury. Understand the signal words DANGER, WARNING, CAUTION,

and  NOTE.  These  words  are  used  with  the  safety-alert  symbol.

DANGER identifies the most serious hazards which will result in severe

personal  injury  or  death.  WARNING  signifies  hazards  which  could

result in personal injury or death. CAUTION is used to identify unsafe

practices  which  may  result  in  minor  personal  injury  or  product  and

property  damage.  NOTE  is  used  to  highlight  suggestions  which  will

result in enhanced installation, reliability, or operation.

EVD4X, ESD4X, WMVC, WMSC

Cased Cooling Only Evaporator Coil

Upflow / Downflow

WARNING

!

PROPERTY DAMAGE HAZARD — FURNACE/COIL 

MATCHING

Failure to follow this warning could result in property damage, personal

injury, or death.

This  coil  must  be  matched  to  heating  equipment  that  meets  all

CSA/ANSI  Z21.47 or  cooling equipment  that meets UL  1995 or  UL

60335-2-40.  Refer  to  the  furnace/blower  installation  instructions  for

any potential considerations when installing coils with composite drain

pans.

CAUTION

!

PARTIAL UNIT REQUIREMENTS

Failure to follow this warning could result in equipment damage.

This  family  of  evaporator  coils  are  PARTIAL  UNIT  AIR

CONDITIONER,  complying  with  PARTIAL  UNIT  requirements  of

UL/CSA  60335-2-40  Standard,  and  must  only  be  connected  to  other

units  that  have  been  confirmed  as  complying  to  corresponding

PARTIAL UNIT requirements of this UL/CSA 60335-2-40 Standard. 

WARNING

!

PERSONAL INJURY / PROPERTY DAMAGE HAZARD

Failure to follow this warning could result in property damage, personal

injury, or death.

For continued  performance,  reliability, and safety, the  only  approved

accessories and replacement parts are those specified by the equipment

manufacturer.  The  use  of  non-manufacturer  approved  parts  and

accessories could invalidate the equipment limited warranty and result

in  fire  risk,  equipment  malfunction,  and  failure.  Please  review

manufacturer’s  instructions  and  replacement  part  catalogs  available

from your equipment supplier.

WARNING

!

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Before installing, modifying or servicing system, always turn off main

power to system. There may be more than one disconnect switch. Lock

out and tag switch with a suitable warning label. 

CAUTION

!

UNIT DAMAGE HAZARD

The coil is 

not approved

 for Heat Pump application. Unit damage may

occur

Содержание EVD4X

Страница 1: ...ath CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions which will result in enhanced installati...

Страница 2: ...refrigerant Use only with outdoor units designed for R 410A NOTE These TXVs are factory set at approximately 10 superheat measured at the suction service valve and are not field adjustable A210138 Fi...

Страница 3: ...he factory installed foil faced insulation in the front and rear of the coil are required to prevent bypass airflow Heat shields for the condensate drain pan in upflow installations and cross members...

Страница 4: ...sted and therefore full performance specifications have not been certified In instances where a not recommended installation configuration is required it is the responsibility of the installer to ensu...

Страница 5: ...using field supplied tubing of refrigerant grade Always evacuate tubing and reclaim refrigerant when making connections or flaring tubing Leak check connections before insulating entire suction line S...

Страница 6: ...n It is highly RECCOMMENDED and in some locals is it a code requirement to install a trap on the drain line s Please use the following guidelines to assure proper drainage Install a trap in condensate...

Страница 7: ...is to be connected to a waste sewer line an open trap must be installed ahead of the waste line to prevent escape of sewer gases Fig 9 Humidifier Application When installing a humidifier in a system...

Отзывы: