background image

Air Purifier Sizes 1620, 1625, 2020, 2025, 2420: Installation Instructions

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

10

To replace the air purifier cartridge, complete the 

following steps:

Turn the heating and cooling system power off.

NOTE: 

Use  of  any  filter  cartridge  in  the  air  purifier  other  than  the

genuine  replacement  purifier  cartridges  listed  in  the  table  below  will

likely result in poor performance and may constitute a safety hazard. Do

not use any third-party air filters in the air purifier.

1. Turn the air purifier switch to the off position.
2. Remove the air purifier door.
3. Slide out the old air purifier cartridge and discard.
4. Install the new air purifier cartridge.

NOTE: 

Verify that the air purifier cartridge is installed correctly. Make

sure  that  the  arrows  on  the  air  purifier  cartridge  point  in  the  same

direction as airflow and match the arrows on the label on the cabinet.

5. Replace the air purifier door.
6. Turn the air purifier switch to the on position.
7. Turn heating and cooling system power on.

At the time of air purifier cartridge replacement, if a powdery residue is

noticed on the tips of the points in the ionization array, proceed to clean

them by completing the following steps.

Turn heating and cooling system power off.

1. Turn the air purifier switch to the off position.
2. Remove the air purifier door.
3. Slide out the Filter Enhancement Module (FEM).

4. Clean the FEM.

NOTE: 

Best cleaning tools: 5 inch (127 mm) handle paint brush with 2

inch (51 mm) width (or greater) brush point (synthetic or natural bristle)

or vacuum cleaner with brush attachment (

Fig. 19

).

Gently stroke the ionization pins with the brush. Use a gentle back and

forth brushing motion to clean any small accumulations from the tips of

the  points. If  desired, use  a vacuum  cleaner with  brush  attachment  to

gently vacuum the frame and components of enhancement module. Also,

if an Accessory Safety Screen is installed, vacuum the Safety Screen to

remove accumulated dust and debris.
If further cleaning of the FEM is needed, it may be washed with soap

and  water  and/or  rinsed  off  with  water.  It  should  not  be  placed  in  a

dishwasher or in boiling water. 

If  using  water  to  clean  the  FEM,  it  must  be  completely  dry  before

inserting back into the air purifier.
Additionally,  care  must  be  taken  when  handling  the  FEM  due  to  the

sharp points on the ionizer.

5. Slide in enhancement module.
6. Replace the air purifier door.
7. Turn the air purifier switch to the on position.
8. Turn heating and cooling system power on.

TROUBLESHOOTING

The air purifier is equipped with a power indicator light located on the

door (

Fig. 18

). This power indicator light will illuminate when the air

purifier door is installed, the power switch is in the on position, AND the

furnace blower is running. If a Flow Sensor Kit (model KIT160000) is

installed in the air purifier and there is no airflow, the power indicator

light will blink slowly (once every 3 seconds) indicating that the purifier

is in “STANDBY” mode. 

WARNING

!

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Before installing or servicing system,  always turn  off main power to

system. There may be more than one disconnect switch. Lock out and

tag switch with a suitable warning label.

PURIFIER MODEL

REPLACEMENT MEDIA CARTRIDGE

DGAPAXX1625

PGAPXCAR1625

DGAPAXX2025

PGAPXCAR2025

DGAPAXX1620

PGAPXCAR1620

DGAPAXX2020

PGAPXCAR2020

DGAPAXX2420

PGAPXCAR2420

WARNING

!

CARBON MONOXIDE HAZARD

Failure to follow this warning could result in personal injury or death.

Do not remove door during blower operation or operate blower with

door removed or improperly latched.

WARNING

!

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Before installing or servicing system,  always turn  off main power to

system. There may be more than one disconnect switch. Lock out and

tag switch with a suitable warning label.

WARNING

!

CUT HAZARD

Failure to follow this warning could result in personal injury.

Sheet metal parts may have sharp edges or burrs. Use care and wear

appropriate protective clothing and gloves when handling parts.

CAUTION

!

SAFETY HAZARD

Failure  to  follow  this  caution  may  result  in  personal  injury  or

equipment damage.
The following instructions are for use by qualified personnel only.

WARNING

!

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

The  following  procedures  will  expose  electrical  components.

Disconnect  power  between  checks  and  proceed  carefully.  Only  a

trained, experienced service person should install and/or troubleshoot

the air purifier.

Содержание DGAPAXX 1620

Страница 1: ...nstaller service agency or your distributor or branch for information or assistance The qualified installer or agency must use factory authorized kits or accessories when modifying this product Refer to the individual instructions packaged with the kits or accessories when installing Follow all safety codes Wear safety glasses protective clothing and work gloves Have a fire extinguisher available ...

Страница 2: ...dels DGAPAXX1620 DGAPAXX2020 and DGAPAXX2420 include the flow sensor as standard equipment as they are designed primarily to be installed with fan coil air handlers A Flow Sensor Jumper Accessory Kit Table 5 is available should there be a need to use air purifier model DGAPAXX1620 DGAPAXX2020 or DGAPAXX2420 with a furnace that has EAC terminals Electrical Power Fusing Air purifier models DGAPAXX16...

Страница 3: ...adhesive backed support foot to the side of the purifier that will be on the floor near the rear of the purifier as shown in Fig 8 Installation Manual Installation Components in accessory bag Door x1 Cabinet x1 Enhancement Module x1 Air Purification Cartridge x1 WARNING ELECTRIC SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained expe...

Страница 4: ...sition Air Flow Air Flow Air Flow Air Flow NOTE Mounting on this side requires the cabinet to be rotated 180 for correct air flow This places the hinged end the door at the top of the cabinet and the handle latch at the bottom Downflow 14 Furnace with Top Mount Upflow 14 Furnace with Bottom Mount Horizontal 14 Furnace with Side Mount Plenum Box Upflow Furnace with Plenum Box Horizontal 24 Furnace ...

Страница 5: ...cing them with pop rivets may have an adverse effect on air sealing or structural integrity of the furnace 6 Use foam tape or silicone sealant between the furnace and the air purifier cabinet 7 Mounting holes are provided in the air purifier flanges for ductwork and furnace attachment To access the mounting holes on the upstream flange of the purifier adjacent to the incoming power wiring the wiri...

Страница 6: ...t connection to the duct and to a furnace controller EAC terminal output The field wiring connection shall be suitable for a maximum possible rating of 90 C of the field wiring terminal box terminals 1 Ensure power has been removed from the heating and cooling system 2 Turn the air purifier power switch off For mounting on furnaces 3 Route the power conduit from the purifier to a knockout on the f...

Страница 7: ...1 4 57 22 7 8 581 Outside 5 8 16 Flanges Where Shown B 19 1 8 486 NOTE Weld 3 places in 4 corners 120 VAC INPUT POWER BLK WHT GRN CHASSIS GROUND FURNACE AIR PURIFIER ASSEMBLY LINE 1 IN EAC 1 NEUTRAL IN EAC 2 Sample Furnace Circuit Board LHT OFF DLY ON OFF W2 BLW EAC 1 TERMINAL Y1 DHUM G COM 24V WW1 Y Y2 R TEST TWIN HUM 1 2 3 PL T ACRDJ 0 5 AMP024 V AC FUSE 3 AMP SEC 1 SEC 2 PL1 NEUTRAL L2 1 EA C 2...

Страница 8: ... the two in line fuses that are provided with the air purifier must be installed in the fan coil wiring compartment START UP AND OPERATION Final Assembly 1 Install the Filter Enhancement Module FEM into the cabinet insuring that FEM is held firmly in place by the retention springs and that the high voltage connector handle is facing outward Fig 15 A11495 Fig 15 Installing FEM 2 Slide the filter in...

Страница 9: ... air purifier cartridge This maintenance reminder can be based on either the TrueSense dirty filter algorithm or time The installer should use their discretion to select the most appropriate option based on the initial system static pressure Maximizing Performance Maximum air purification performance is obtained when the furnace blower is set for continuous operation on the thermostat or Control M...

Страница 10: ...ean the FEM it must be completely dry before inserting back into the air purifier Additionally care must be taken when handling the FEM due to the sharp points on the ionizer 5 Slide in enhancement module 6 Replace the air purifier door 7 Turn the air purifier switch to the on position 8 Turn heating and cooling system power on TROUBLESHOOTING The air purifier is equipped with a power indicator li...

Страница 11: ...lem reoccurs Misaligned or damaged purifier door Insure that door is undamaged and properly installed on purifier cabinet Damaged or disconnected incoming power wiring Call for service ON continuously Air purifier on Normal operation when airflow is present FLASHING 1 flash every 4 seconds Standby Mode Normal operation when airflow is not present for models with flow sensor Ions detected in airflo...

Страница 12: ...e filter and not contacting the cabinet or door back If springs are broken or damaged replace the door assembly RAPID FLASHING 5 flashes per second LED Flashes for 10 seconds when AC power is turned on indicating a previously stored error code code will be displayed after 10 seconds Purifier will not operate until cause of error condition is rectified and purifier is reset An error code was regist...

Страница 13: ...lacement Filters Replacement Component Kits and Accessories Air Purifier Model DGAPAXX 1625 2025 1620 2020 2420 Filter Enhancement Module FEM KIT140000 KIT141000 KIT142000 KIT143000 KIT144000 Front Door including Power Supply KIT156000 KIT157000 KIT156000 KIT157000 KIT158000 Flow Sensor KIT160000 Included as standard with Models DGAPAXX1620 DGAPAXX2020 and DGAPAXX2420 Flow Sensor Bypass KIT161000 ...

Отзывы: