Air Purifier Sizes 1620, 1625, 2020, 2025, 2420: Installation Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
8
A12251
Fig. 14 – Quick Connect Kit Installation Illustration
For mounting to fan coil air handlers:
1. Route the power conduit from the purifier to a knockout on the fan
coil air handler that provides access to the incoming power wiring
compartment. Affix the end of the conduit to the fan coil air handler
using the included conduit fitting.
2. Remove the yellow and black primary wires from the fan coil air
handler transformer terminals and connect the quick connect
“piggyback” terminals of the quick connect kit leads exiting the air
purifier power conduit assembly to the transformer terminals.
Reconnect the yellow and black primary wires to their respective
transformer terminals on the “piggyback” terminals. Attach the
ground ring terminal on the third wire to fan coil air handler chassis
ground (
and
).
Power connections are to be made inside the fan coil wiring
compartment per local electrical codes, and the two in-line fuses that are
provided with the air purifier must be installed in the fan coil wiring
compartment.
START-UP AND OPERATION
Final Assembly
1. Install the Filter Enhancement Module (FEM) into the cabinet,
insuring that FEM is held firmly in place by the retention springs
and that the high voltage connector/handle is facing outward
).
A11495
Fig. 15 – Installing FEM
2. Slide the filter into the cabinet next to the FEM with the filter
pull-tab facing outward and paying particular attention to the
airflow direction arrows (
).
A11496
Fig. 16 – Replace Filter
3. Insert the brand logo into the front of the door panel. To insure that
the logo is installed in the proper orientation, first attach the door to
the purifier and then snap the logo into place with the text in upright
position (
).
4. Affix the “Captures & Kills” label to the front of the purifier door
as desired.
CAUTION
!
UNIT COMPONENT DAMAGE HAZARD
Failure to follow this caution may result in equipment damage or
improper operation.
For Furnace Purifiers:
Black Lead - Connect to Hot (L1) or EAC-1 when provided.
White Lead - Connect to Neutral (L2) or EAC-2 when provided.
Green/Ground Lead - Connect to Appliance Ground (Chassis).
For Fan Coil Purifiers:
Black Lead - Connect to L1
White Lead - Connect to L2
Green Lead - Connect to Appliance Ground (Chassis)