4 - PhYsICal DaTa - 30RQ
30RQ
262
302
342
372
402
432
462
522
Nominal cooling capacity*
kW
243
275
310
331
366
389
430
465
Total power input, cooling mode*
kW
98
106
122
125
146
150
166
192
Nominal heating capacity**
kW
273
307
344
364
413
450
510
560
Total power input, heating mode**
kW
95
110
123
126
148
158
180
201
sound levels 10
-12
W†
dB(a)
Unit with Euro Pack option
89
90
90
91
91
92
92
92
Standard unit
91
92
92
93
93
94
94
94
Operating weight***
Standard unit with Euro Pack option
kg
2619
3285
3481
3544
3718
4328
4530
4704
Standard unit with Euro Pack option and high-
pressure dual-pump hydronic module option
kg
2864
3590
3786
3889
4063
4673
4945
5119
Unit without options****
kg
2429
3045
3241
3284
3458
4028
4210
4384
Refrigerant
R-410A
Circuit A
kg
27
41
41
53
54
54
53
54
Circuit B
kg
27
27
27
32
32
47
53
53
Compressors
Hermetic scroll 48.3 r/s
Circuit A
2
3
3
4
4
4
4
4
Circuit B
2
2
2
2
2
3
4
4
No. of control stages
4
5
5
6
6
7
8
8
Minimum capacity
%
25
18
20
15
17
13
11
13
Control
PRO-DIALOG Plus
air heat exchangers
Grooved copper tubes and aluminium fins
Fans
Axial FLYING BIRD 4 with rotating shroud
Quantity
4
5
5
6
6
7
8
8
Total air flow
l/s
18056
22569
22569
27083
27083
31597
36111
36111 Speed
r/s
15.7
15.7
15.7
15.7
15.7
15.7
15.7
15.7
Water heat exchangers
Direct-expansion, two circuits, shell-and-tube
Water volume
l
110
110
125
113
113
113
113
113
Max. water-side operating pressure
without hydronic module
kPa
1000
1000
1000
1000
1000
1000
1000
1000
hydronic module (option)
Pump, Victaulic screen filter, safety valve, expansion tank, pressure gauge, purge valves (water and air) and
water flow control valves
Water pump
Centrifugal, monocell, 48.3 r/s, low or high pressure (as required), single or dual pump
Quantity
1
1
1
1
1
1
1
1
Expansion tank volume
l
50
80
80
80
80
80
80
80
Max. water-side operating pressure
with hydronic module
kPa
400
400
400
400
400
400
400
400
Water connections without hydronic module
Victaulic
Connections
in.
4
4
4
6
6
6
6
6
Outside tube diameter
mm
114.3
114.3
114.3
168.3
168.3
168.3
168.3
168.3
Water connections with hydronic module
Victaulic
Connections
in.
4
4
4
5
5
5
5
5
Outside tube diameter
mm
114.3
114.3
114.3
139.7
139.7
139.7
139.7
139.7
*
Standardised Eurovent conditions: water heat exchanger entering/leaving water temperature 12°C/7°C, outside air temperature 35°C, water heat exchanger fouling
factor 0.000018 m
2
K/W (rounded values, for information only).
** Standardised Eurovent conditions: water heat exchanger entering/leaving water temperature 40°C/45°C, outside air temperature 7°C, 87% rh (rounded values, for
information only).
*** Weights are for guidance only. To find out the unit refrigerant charge, please refer to the unit name plate.
**** Standard unit: Base unit without Euro Pack option and hydronic module.
†
In accordance with ISO 9614-1 and Eurovent certified (rounded values, for information only).
3.3 - Multiple heat pump installation
NOTE: If the walls are higher than 2 m, contact the factory
3000
1500
3000
1500
3000
3000
1500
1500
1500
A
B
B
B
B
B
B
B
B
A
In case of multiple heat pumps (up to four units), the respective clearance
between them should be increased from 1500 to 3000 mm for the side space
requirement.
If necessary, add the required clearances for water heat exchanger tube or coil
removal.