70
Table 7 — 30XA140-500 Electrical Data, Single Point (High Ambient Option) (cont)
LEGEND
NOTES:
1. Units are suita
b
le for use on electrical systems where voltage supplied to the unit ter-
minals is not
b
elow or a
b
ove the listed minimum and maximum limits. Maximum allow-
a
b
le phase im
b
alance is: voltage, 2
%
; amps 10
%
.
2. Cooler heater is wired into the control circuit so it is always opera
b
le as long as the
control power supply disconnect is on, even if any safety device is open.
3. For MCA that is less than or e
q
ual to 3
8
0 amps, 3 conductors are re
q
uired.
For MCA
b
etween 3
8
1-760 amps, 6 conductors are re
q
uired.
For MCA
b
etween 761-1140 amps, 9 conductors are re
q
uired.
For MCA
b
etween 1141-1520 amps, 12 conductors are re
q
uired.
Calculation of conductors re
q
uired is
b
ased on 75 C copper wire.
4. Wiring for main field supply must
b
e rated 75 C minimum. Use copper for all units.
a. Incoming wire size range for the terminal
b
lock is no. 4 AWG (American Wire Gage)
to 500 kcmil.
b
. Incoming wire size range of non-fused disconnect with MCA up to 599.9 amps is
3/0 to 500 kcmil.
c. Incoming wire size range of non-fused disconnect with MCA from 600 to 799.9 amps
is 1/0 to 500 kcmil.
d. Incoming wire size range of non-fused disconnect with MCA from
8
00 to 1199.9 amps
is 250 kcmil to 500 kcmil.
5. Data provided circuit 1/circuit 2 where there are two circuits.
UNIT
30XA
UNIT VOLTAGE
NUMBER
OF
COND
FANS
10 HP PUMP, 3450 RPM
15 HP PUMP, 3450 RPM
CONTROL CIRCUIT
V-Hz
(3 Ph)
Supplied
MCA
MOCP
ICF
Rec
Fuse
Size
MCA
MOCP
ICF
Rec
Fuse
Size
Voltage
1 PH,
60 Hz
MCA
and
MOCP
Min
Max
WD
XL
WD
XL
140
230-60
207
253
10
592.4
8
00
8
69.3
—
700
607.0
8
00
88
3.9
—
700
115
40
200-60
1
8
7
220
10
652.4
8
00
9
8
6.5
—
8
00
66
8
.6
8
00
1002.6
—
8
00
115
40
460-60
414
506
10
296.2
400
434.7
1066.7
350
303.5
400
442.0
1074.0
350
115
40
575-60
51
8
633
10
22
8
.4
300
344.6
8
50.6
300
234.3
300
350.5
8
56.5
300
115
40
3
8
0-60
342
41
8
10
346.7
450
523.0
12
88
.0
400
355.5
500
531.9
1296.9
400
115
40
160
230-60
207
253
10
673.1
8
00
1067.1
—
8
00
6
8
7.7
8
00
10
8
1.7
—
8
00
115
40
200-60
1
8
7
220
10
740.5
1000
1213.0
—
1000
756.6
1000
1229.1
—
1000
115
40
460-60
414
506
10
335.7
450
533.2
1341.2
400
343.0
450
540.5
134
8
.5
400
115
40
575-60
51
8
633
10
259.4
350
424.3
1070.3
300
265.2
350
430.1
1076.1
300
115
40
3
8
0-60
342
41
8
10
393.3
500
641.2
1620.2
450
402.1
500
650.0
1629.0
450
115
40
180
230-60
207
253
12
—
—
—
—
—
—
—
—
—
—
115
40
200-60
1
8
7
220
12
—
—
—
—
—
—
—
—
—
—
115
40
460-60
414
506
12
—
—
—
—
—
—
—
—
—
—
115
40
575-60
51
8
633
12
—
—
—
—
—
—
—
—
—
—
115
40
3
8
0-60
342
41
8
12
—
—
—
—
—
—
—
—
—
—
115
40
200
230-60
207
253
12
—
—
—
—
—
—
—
—
—
—
115
40
200-60
1
8
7
220
12
—
—
—
—
—
—
—
—
—
—
115
40
460-60
414
506
12
—
—
—
—
—
—
—
—
—
—
115
40
575-60
51
8
633
12
—
—
—
—
—
—
—
—
—
—
115
40
3
8
0-60
342
41
8
12
—
—
—
—
—
—
—
—
—
—
115
40
220
230-60
207
253
13
—
—
—
—
—
—
—
—
—
—
115
40
200-60
1
8
7
220
13
—
—
—
—
—
—
—
—
—
—
115
40
460-60
414
506
13
—
—
—
—
—
—
—
—
—
—
115
40
575-60
51
8
633
13
—
—
—
—
—
—
—
—
—
—
115
40
3
8
0-60
342
41
8
13
—
—
—
—
—
—
—
—
—
—
115
40
240
230-60
207
253
13
—
—
—
—
—
—
—
—
—
—
115
40
200-60
1
8
7
220
13
—
—
—
—
—
—
—
—
—
—
115
40
460-60
414
506
13
—
—
—
—
—
—
—
—
—
—
115
40
575-60
51
8
633
13
—
—
—
—
—
—
—
—
—
—
115
40
3
8
0-60
342
41
8
13
—
—
—
—
—
—
—
—
—
—
115
40
260
460-60
414
506
15
—
—
—
—
—
—
—
—
—
—
115
40
575-60
51
8
633
15
—
—
—
—
—
—
—
—
—
—
115
40
3
8
0-60
342
41
8
15
—
—
—
—
—
—
—
—
—
—
115
40
280
460-60
414
506
16
—
—
—
—
—
—
—
—
—
—
115
40
575-60
51
8
633
16
—
—
—
—
—
—
—
—
—
—
115
40
3
8
0-60
342
41
8
16
—
—
—
—
—
—
—
—
—
—
115
40
300
460-60
414
506
16
—
—
—
—
—
—
—
—
—
—
115
40
575-60
51
8
633
16
—
—
—
—
—
—
—
—
—
—
115
40
3
8
0-60
342
41
8
16
—
—
—
—
—
—
—
—
—
—
115
40
325
460-60
414
506
1
8
—
—
—
—
—
—
—
—
—
—
115
40
575-60
51
8
633
1
8
—
—
—
—
—
—
—
—
—
—
115
40
3
8
0-60
342
41
8
1
8
—
—
—
—
—
—
—
—
—
—
115
40
350
460-60
414
506
1
8
—
—
—
—
—
—
—
—
—
—
115
40
575-60
51
8
633
1
8
—
—
—
—
—
—
—
—
—
—
115
40
3
8
0-60
342
41
8
1
8
—
—
—
—
—
—
—
—
—
—
115
40
400
460-60
414
506
20
—
—
—
—
—
—
—
—
—
—
115
50
575-60
51
8
633
20
—
—
—
—
—
—
—
—
—
—
115
50
3
8
0-60
342
41
8
20
—
—
—
—
—
—
—
—
—
—
115
50
450
460-60
414
506
22
—
—
—
—
—
—
—
—
—
—
115
50
575-60
51
8
633
22
—
—
—
—
—
—
—
—
—
—
115
50
3
8
0-60
342
41
8
22
—
—
—
—
—
—
—
—
—
—
115
50
500
460-60
414
506
22
—
—
—
—
—
—
—
—
—
—
115
50
575-60
51
8
633
22
—
—
—
—
—
—
—
—
—
—
115
50
3
8
0-60
342
41
8
22
—
—
—
—
—
—
—
—
—
—
115
50
ICF
—
Instantaneous Current Flow
MCA
—
Minimum Circuit Amps
MOCP —
Maximum Overcurrent Protection
WD
—
Wye-Delta
XL
—
Across-the-Line
Содержание AQUAFORCE 30XA080
Страница 79: ......