26
Option 31* — Daylight Savings Time Configuration
(programmable models only)
Option 32
— Furnace Heat Staging
Option 33
— Single or Two--Piece Installation
Option 34
— Hybrid Heat Furnace Latch
Option 40
— Fan Humidify
Option 41
— Variable Speed Blower
Option 42
— Variable Speed Super Dehumidification
Option 43
— Intelligent Heat Staging
Option 44
— Super Comfort Heat
Option 99
— Reset to Factory Defaults
TO ENTER CONFIGURATION MODE
Press and hold FAN button for approximately 10 sec. The Display Module is now in
configuration mode. It will automatically exit this mode if no button is pressed for 3
minutes. Pressing the DONE button will exit configuration mode immediately.
WHILE IN CONFIGURATION MODE
The option number is displayed in the heat setpoint location and the configuration
setting is displayed in the cool setpoint location. On the TP--PRH--A, --B
(programmable) model, a box will surround the option number. The mode button is
used to move the box between the two displayed values. The soft keys below the
listed values may also be used to move the box between selected values. The value
inside the box is changed by using the UP/DOWN buttons. On the TP--NRH--A, --B
(non--programmable) model, one of the values will be flashing. The mode button is
used to change which value is flashing or the Home and Sleep buttons may also be
used to select which value to flash. The value that is flashing is changed by using
the UP/DOWN buttons. All changes made are saved at the time of selection and
will be saved in the event of the 3 minute time--out or when installer exits from
configuration menu.
Содержание A07048
Страница 2: ......
Страница 10: ...8 A13295 Fig 2 Coil Excess Wiring A07685 Fig 3 TP PRH A B Carton Contents ...
Страница 15: ...13 A07225 Fig 5 Press Tabs to Remove Backplate A07226 Fig 6 Take Apart ...
Страница 18: ...16 A07166 Fig 9 Secure Wires to Terminal Strip A07167 Fig 10 Connect Pigtail Wires to Display Module ...
Страница 89: ...87 NOTES ...
Страница 90: ...88 NOTES ...
Страница 91: ......