TIMER 

MODE — 

Your Carrier Air Conditioner 

unit can be programmed so that the unit will shut off 
after a certain number of hours (if operating) or turn 
on after a certain number of hours (if off).
Press the Timer button to start the Timer mode. The 
number of hours will start at 0. The range is 0 to 
24 hours.
If the unit is operating, the number of hours until the 
unit will turn off will be displayed. If the unit is off, 
the number of hours until the unit will turn on will be 
displayed. Use the UP and DOWN ARROW buttons to 
change the number of hours.
Press the Timer button again to cancel Timer mode.

EXHAUST AIR LEVER

 — 

The 73KCA081 units 

are equipped with an exhaust air lever. When the 
lever is pushed in, the air conditioner will circulate 
room air only. When the lever is pulled out, the air 
conditioner will exhaust some room air to the outside.

ENERGY SAVING TIPS

Your Carrier air conditioner is designed to operate 
efficiently and save on energy costs. Follow these rec-
ommendations for even greater energy savings.
• Select the warmest thermostat setting that will suit 

your comfort needs and leave the thermostat at that 
setting.

• Keep the air filter clean (clean approximately every 

30 days).

• Use drapes, curtains, or shades to keep direct sun-

light from heating the room.

• Do not obstruct the front panel air intake. Do not 

obstruct the top air discharge. Allow air to circulate 
freely around the air conditioner.

• Start your air conditioner before outdoor tempera-

ture, cooking heat, or groups of people make the 
room hot and uncomfortable. This avoids an initial 
period of discomfort while the air conditioner is cool-
ing the room.

• When outdoor temperature is cool enough, use the 

Fan Only setting. This circulates indoor air, pro-
vides comfort, and utilizes less electricity than 
when operating in cooling modes.

MAINTENANCE

When servicing the air conditioner, make sure the 
mode is set to OFF and the unit is unplugged from the 
electrical outlet.

CLEAN FILTER

Normally, the air filter should be cleaned every
30 days. The filter is highly efficient in removing

airborne particles. More frequent cleaning may be 
required in areas with low outdoor and indoor air 
quality.
To remove the filter, grasp the filter handle tabs on 
the top center of the front inlet grille and slide the fil-
ter out to the top. The filter may be vacuumed or 
washed by hand in warm water. Use of a mild deter-
gent is recommended. Dry the filter thoroughly after 
washing. Replace the air filter by sliding it back into 
the filter slot. Do not operate the unit without the 
filter.

CLEAN FRONT PANEL

The front panel may be cleaned after it is removed 
from the air conditioner. Wash the grille by hand with 
warm water and a mild soap. Be sure to thoroughly 
dry the grille before reinstalling. Never pour water 
directly on the unit. Do not use gasoline, thinner, or 
other chemicals to clean unit.

CLEAN BASEPAN

The basepan may need to be cleaned if there is a 
build-up of mold, mildew or algae that could cause 
unpleasant odors. When outdoor humidity is high, con-
densate may not fully evaporate from basepan during 
normal operation. To clean the basepan, run the air 
conditioner in Fan Only mode for 4 to 6 hours to 
remove condensate. Remove the front panel. Use 
bleach or other cleaner to remove mold, mildew, or 
algae from basepan. Replace front panel.

CARE OF THE REMOTE CONTROL

The remote control should last indefinitely with proper 
care. Do not expose the remote control to direct heat. 
Do not spill liquids or place heavy objects on the 
remote control. Make sure the signal from the remote 
control to the air conditioner is unobstructed.

REMOTE CONTROL BATTERY
REPLACEMENT

If the remote control stops working, the battery should 
be replaced. The battery used is a 3-volt lithium 
CR2025. This battery or an equivalent should be avail-
able at a local electronics store or electronics section of 
a department store.
To replace the battery, find the small tab on the back 
of the remote control. With a fingernail or screwdriver, 
slide out the battery drawer using the tab. Remove 
and recycle the old battery. Insert the new battery into 
the drawer with the numbers facing up. The battery 
will only fit into the drawer one way. Gently slide the 
battery drawer back into the remote control.

Содержание 73KCA051D

Страница 1: ..._____________________________________________________ MODEL CATALOG NUMBER _______________________________________ SERVICE DISCRETE NUMBER _____________________________________ SERIAL NUMBER ________...

Страница 2: ...iption of the unit REQUIRED TOOLS Phillips and flathead screwdrivers pencil level measuring tape drill 1 8 in drill bit scissors CABINET EXTERIOR AIR INLET INTERIOR AIR OUTLET CONTROL KNOBS POWER CORD...

Страница 3: ...he window and frame are structurally sound and free from dry or rotted wood Replace wood if necessary or relocate to different window For maximum efficiency install the air conditioner on the side of...

Страница 4: ...g 4 After the foam seal has been cut remove the peel off backing and stick to bottom of window 7 Measure the width of the inside sill of the window and mark the center of the sill See Fig 5 Mea sure 7...

Страница 5: ...in the pan els See Fig 8 12 Drill the holes marked in Step 11 with 1 8 in drill bit With the wing panels expanded secure the wing panels with two 3 4 in screws provided each side See Fig 8 13 Cut thic...

Страница 6: ...be set to different modes of cooling and fan operation and a thermostat dial to set desired room temperature See Fig 10 The electronic control consists of a control panel and a remote control Both th...

Страница 7: ...F the unit will turn off no cooling or fan At all other times cooling will be off and the fan will run on Low speed FAN SPEED The air conditioner Fan mode can be set to High Medium Low or Auto Press t...

Страница 8: ...he filter is highly efficient in removing airborne particles More frequent cleaning may be required in areas with low outdoor and indoor air quality To remove the filter grasp the filter handle tabs o...

Страница 9: ...ation started Allow sufficient time for unit to cool room Compressor Overload tripped Let fan run for approximately 10 minutes to reset compressor overload and restart compressor UNIT MAKING NOISES N...

Страница 10: ...KCA SERIES 10 FIGURE 12 SCHEMATIC DIAGRAM MODEL KCA051D...

Страница 11: ...11 LEGEND FIGURE 13 SCHEMATIC DIAGRAM MODELS KCA061P AND KCA081P CN Connection RY Relay...

Страница 12: ...during normal working hours All replacement parts whether new or remanufactured assume as their warranty period only the remaining time period for which the applicable component is expressly warranted...

Страница 13: ..._______________________________________ NUM RO DE MOD LE CATALOGUE ________________________________ NUM RO DE SERVICE UNIQUE ____________________________________ NUM RO DE S RIE ______________________...

Страница 14: ...pareil OUTILS N CESSAIRES Tournevis Phillips et t te plate crayon niveau bulle d air ruban de mesure perceuse foret 1 8 po ciseaux CAISSON ENTR E D AIR EXT RIEUR SORTIE D AIR INT RIEUR BOUTONS DE COMM...

Страница 15: ...e la fen tre et du cadre sont solides et exemptes de bois sec ou pourri S il y a lieu remplacez le bois ou installez le climatiseur dans une autre fen tre Pour une efficacit maximale installez l appar...

Страница 16: ...ez les volets au caisson l aide des vis de 3 8 po 0 95 cm comprises Consultez la Figure 3 6 Un fin morceau de mousse sceller est compris Coupez un morceau correspondant la largeur du bas du ch ssis de...

Страница 17: ...es volets ouverts marquez l endroit o vous devrez percer sur les c t s du cadre et de l appui de la fen tre en passant par les trous des volets Consultez la Figure 8 12 Percez les trous marqu s lors d...

Страница 18: ...l commande Le panneau de commande et la t l commande peuvent tous deux tre utilis s pour r gler les modes de climatisation et de ventilation ainsi que pour r gler la temp rature d sir e Consultez la F...

Страница 19: ...de climatisation au mode de ventilation seulement lorsque la climatisation n est pas n cessaire Il est impossible de s lectionner la vitesse du ventilateur en mode d conomie d nergie Lorsque la temp r...

Страница 20: ...de inconfortable Vous viterez ainsi une p riode d inconfort initiale pendant que le climatiseur rafra chit la pi ce Lorsque la temp rature ext rieure est assez fra che n utilisez que le mode de ventil...

Страница 21: ...evez tous les obstacles pouvant l obstruer Le r glage de temp rature du thermostat est trop lev R glez le thermostat une temp rature plus basse plus froide Le filtre air de l appareil est sale Retirez...

Страница 22: ...KCA S RIE 22 FIGURE 12 SCH MA MOD LE KCA051D...

Страница 23: ...23 L GENDE FIGURE 13 SCH MA MOD LES KCA061P ET KCA081P CN Connexion RY Relais...

Страница 24: ...ent neuves ou remises neuf ont pour p riode de garantie la p riode restante pour laquelle le composant applicable est express ment garanti par la pr sente Les distributeurs ou stations de service ind...

Страница 25: ..._______________________________________ N M DE MODELO CAT LOGO ____________________________________ N M DE SERVICIO _______________________________________________ N M DE SERIE _______________________...

Страница 26: ...SARIAS un destornillador Phillips y otro normal un l piz un nivel de burbuja un metro un taladro una broca de 1 8 de pulg tijeras CAJA ENTRADA DE AIRE EXTERIOR SALIDA DE AIRE AL INTERIOR CONTROLES CAB...

Страница 27: ...a realizar la instalaci n apropiadamente y de forma segura Compruebe que la ventana y el marco est n en buena condici n y que no haya madera reseca ni podrida Reemplace la madera si es necesario o hag...

Страница 28: ...la caja arriba y abajo de la unidad Fije los postigos a la caja con los cuatro tornillos de 3 8 de pulgada incluidos Vea la Fig 3 6 Con la unidad se incluye tambi n una tira delgada de espuma sellado...

Страница 29: ...stigos hay una leng eta para asegurarlos al batiente de la ventana Cuando tenga los paneles extendidos marque los puntos de perforaci n a cada lado del marco y del batiente de la ventana a trav s de l...

Страница 30: ...n Vea la Fig 10 El control electr nico consiste de un panel de control y de un mando a distancia Tanto el panel de control como el mando a distancia se pueden usar para programar las modalidades de en...

Страница 31: ...de ajustar con el bot n FAN SPEED velocidad ventilador La opci n Auto no se puede escoger en la modalidad Fan Only s lo ventilador En la modalidad Energy Saving la unidad pasa autom ticamente de la mo...

Страница 32: ...rmostato programado a esa temperatura Mantenga limpio el filtro de aire l mpielo aproxi madamente cada 30 d as Ponga cortinas o persianas para que los rayos solares no suban la temperatura de la habit...

Страница 33: ...ga y revise el flujo de aire en el exterior quite los obst culos que puedan haber La temperatura del termostato es demasiado alta Programe el termostato a una temperatura m s baja fr a El filtro de ai...

Страница 34: ...SERIE KCA 34 FIGURA 12 DIAGRAMA ESQUEM TICO MODELO KCA051D...

Страница 35: ...35 CLAVE FIGURA 13 DIAGRAMA ESQUEM TICO MODELOS KCA061P Y KCA081P CN Conexi n RY Rel...

Страница 36: ...males Todas las piezas de repuesto ya sean nuevas o refabricadas asumen como per odo de garant a s lo el per odo de tiempo restante para el que el componente correspondiente est garantizado expresamen...

Отзывы: