3
−
2
T-364
3.1.1 Keypad
The keypad (Figure 3
door. The keypad consists of eleven push button
switches that act as the user’s interface with the control-
ler. Descriptions of the switch functions are provided in
ENTER
BATTERY
POWER
MANUAL
DEFROST/
INTERVAL
CODE
SELECT
PRE
TRIP
ALARM
LIST
ALT.
MODE
RETURN
SUPPLY
C
F
Figure 3
−
2 Keypad
3.1.2 Display Module
The display module (Figure 3
displays and seven indicator lights. The indicator lights
include:
1. COOL - Blue LED: Energized when the refrigerant
compressor is energized.
2. HEAT - Orange LED: Energized to indicate heater
operation in heat mode, defrost mode, or
dehumidification.
3. DEFROST - Orange LED: Energized when the unit
is in defrost mode.
4. IN RANGE - Green LED: Energized when the con-
trolled temperature probe is within the specified toler-
ance of set point.
Table 3
−
1 Keypad Function
KEY
FUNCTION
CODE SELECT Accesses function codes.
PRE TRIP
Displays Pre-trip selection menu.
Discontinues Pre-trip in progress.
ALARM LIST
Displays alarm list and clears the
alarm queue.
MANUAL
DEFROST /
INTERVAL
Displays selected defrost mode.
Depress and hold the MANUAL
DEFROST / INTERVAL key for
five (5) seconds to initiate defrost
using the same logic as if the op-
tional manual defrost switch was
toggled on.
ENTER
Confirms a selection or saves a
selection to the controller.
Arrow Up
Change or scroll a selection up.
Pre-trip advance or test interrupt.
Arrow Down
Change or scroll selection down-
ward. Pre-trip repeat backward.
RETURN /
SUPPLY
Display non-controlling probe tem-
perature (momentary display).
Celsius /
Fahrenheit
Display alternate English/Metric
scale (momentary display). When
set to F, pressure is displayed in
psig and vacuum in “/hg.” “P” ap-
pears after the value to indicate
psig and “i” appears for inches of
mercury. When set to C, pressure
readings are in bars. “b” appears
after the value to indicate bars.
BATTERY
POWER
Initiate battery backup mode to al-
low set point & function code se-
lection if AC power is not con-
nected.
ALT MODE
This key is pressed to switch the
functions from temperature soft-
ware to the DataCORDER soft-
ware. The remaining keys function
the same as described above ex-
cept the readings or changes are
made to the DataCORDER pro-
gramming.
NOTE
The controlling probe in perishable range is the
SUPPLY air probe and the controlling probe in
frozen range is the RETURN air probe.
5. SUPPLY - Yellow LED: Energized when the supply
air probe is used for control. When this LED is illu-
minated, the temperature displayed in the AIR TEM-
PERATURE display is the reading at the supply air
probe. This LED will flash if dehumidification or hu-
midification is enabled.
6. RETURN - Yellow LED: Energized when the return
air probe is used for control. When this LED is illu-
minated, the temperature displayed in the AIR TEM-
PERATURE display is the reading at the return air
probe.
7. ALARM - Red LED: Energized when an active or an
inactive shutdown alarm in the alarm queue.
Содержание 69NT40-561-201
Страница 2: ......
Страница 11: ......
Страница 15: ......
Страница 29: ......
Страница 81: ......
Страница 108: ...7 2 T 364 Based on Drawing 62 11753 Figure 7 2 SCHEMATIC DIAGRAM ...
Страница 109: ...7 3 T 364 Based on Drawing 62 11753 Figure 7 3 UNIT WIRING DIAGRAM Sheet 1 of 2 ...
Страница 110: ...7 4 T 364 Based on Drawing 62 11753 Figure 7 3 UNIT WIRING DIAGRAM Sheet 2 of 2 ...
Страница 111: ......
Страница 115: ......
Страница 116: ......