T-354
4–4
The Micro-Link 3 controller is a dual module microprocessor as shown in
. It is fitted with test points, har-
ness connectors and a software card programming port.
Figure 4.4 Control Module
1. Mounting Screw
2. Micro-Link 3 Control/DataCORDER Module
3. Connectors
4. Test Points
5. Fuses
6. Control Circuit Power Connection
7. Software Programming Port
8. Battery Pack (Standard Location)
- - - - -
4.2
CONTROLLER SOFTWARE
The controller software is a custom designed program that is subdivided into the configuration software and the
operational software. The controller software performs the following functions:
a. Control supply or return air temperature to required limits, provide modulated refrigeration control, elec-
tric heat control and defrost. Defrost is performed to clear buildup of frost and ice from the coil to ensure
continuous conditioned air delivery to the load.
b. Provide default independent readouts of set point and supply or return air temperatures.
c. Provide ability to read, and if applicable, modify the configuration software variables, operating software
function codes, and alarm code indications.
d. Provide a pre-trip step-by-step checkout of refrigeration unit performance, including proper component
operation, electronic and refrigeration control operation, heater operation, probe calibration, pressure lim-
iting, and current limiting settings.
e. Provide battery-powered ability to access or change selected codes and set points without AC power
connected.
f. Provide the ability to reprogram the software through the use of a memory card.
4.2.1
Configuration Software (Configuration Variables)
The configuration software is a variable listing of the components available for use by the operational software.
This software is factory-installed in accordance with the equipment fitted and options listed on the original purchase
order. Changes to the configuration software are required only when the original software has been lost or a phys-
ical change has been made to the unit, such as the addition or removal of an option. A configuration variable list is
provided in
. A change to the factory-installed configuration software is achieved via a configuration card.
4.2.2
Operational Software (Function Codes)
The operational software is the actual operation programming of the controller, which activates or deactivates com-
ponents in accordance with current unit operation conditions and operator selected modes of operation.
The programming is divided into function codes. Some of the codes are read only while the remaining codes may
be user configured. The value of the user configurable codes can be assigned in accordance with user desired
mode of operation. A list of the function codes is provided in
.
MA
CONTROLLER
Micro-Link3
With
DataCORDER
MB
MC
F2
(5A)
TP
F1
(5A)
F3A
(7.5A)
F3B
(7.5A)
KH
OC1
KA
EN12830
CARRIER
S/N: 0491162
T B C1
KE
REV 5147 YYWW:
KD
1035
KC
12-00579-00
59980
KB
Содержание 69NT40-541-306
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 14: ......
Страница 78: ...T 354 5 8 Figure 5 3 Controller Operation Perishable Mode Figure 5 4 Controller Operation Frozen Mode ...
Страница 142: ...T 354 8 2 Figure 8 2 Schematic Diagram Standard Unit Configuration BASED ON 62 66686 00 ...
Страница 143: ...8 3 T 354 Figure 8 3 Unit Wiring Diagram Standard Unit Configuration 1 of 2 BASED ON 62 66686 00 ...
Страница 144: ...T 354 8 4 Figure 8 4 Unit Wiring Diagram Standard Unit Configuration 2 of 2 BASED ON 62 66686 00 ...
Страница 148: ...T 354 8 8 ...
Страница 152: ......
Страница 153: ......