INTRODUCTION
11
ECMCT REFRIGERATION/ELECTRICAL DATA
Export Models (R-404A)
ECMCT-4
OHMS WATTS
AMPS
VOLTS
Def. Heater on Bottom side
72.4
582
2.7
215
of Top Coil
Control Bellows Heater below
5375
9
.04
215
Def. Controls
End Breaker Heater behind
3071.4
15
.07
215
each End Breaker
Glass Heater around
826.9
56
.26
215
Front Glass
Heated Glass Lid
41.3
14
.58
24
(each)
ECMCT-6
OHMS WATTS
AMPS
VOLTS
Def. Heater on Bottom side
51
904
4.2
215
of Top Coil
Control Bellows Heater below
5375
9
.04
215
Def. Controls
End Breaker Heater behind
3071.4
15
.07
215
each End Breaker
Glass Heater around
565.8
82
.38
215
Front Glass
Heated Glass Lid
26.1
22
.92
24
(each)
COMPRESSOR AMPERAGE
CABINET
RUN
CAP.
MODEL
MFG.
MODEL
HP
VOLTS
LRA
AMPS
OZ.
TUBE
ECMCT-4
Copeland
KAJB-010E-CAV
1
200
40
8.0
20
8' x .042
ECMCT-6
Copeland
KAJB-010E-CAV
1
200
40
8.0
25
8' x .042
Содержание 52-2038-01
Страница 3: ...SECTION I Introduction...
Страница 13: ...12 INTRODUCTION WIRING DIAGRAM 00 1667 00 CMCT 4 6 8...
Страница 14: ...INTRODUCTION 13 WIRING DIAGRAM 00 1670 00 CMCT 10...
Страница 15: ...14 INTRODUCTION WIRING DIAGRAM 00 1934 00 ECMCT 4 6 8 Export Models...
Страница 16: ...INTRODUCTION 15 LAMP WIRING DETAIL Upper Raceway Typical...
Страница 17: ...SECTION II Maintenance Repair...
Страница 23: ...CONDENSING UNIT LAYOUT 24 MAINTENANCE REPAIR...
Страница 32: ...UPPER CROSS SECTION CMCT Models...
Страница 38: ...SECTION III Parts List...