3
R e s i d e n t i a l D i g i t a l P a c k a g e d U n i t s G T- P B S e r i e s - 6 0 H z P u ro n
®
R e v : 4 A p r i l , 1 4
Model Nomenclature: General Overview
WARNING!
WARNING!
CAUTION!
WARNING!
To avoid the release of refrigerant into the
atmosphere, the refrigerant circuit of this unit must be
serviced only by technicians who meet local, state, and
federal pro
fi
ciency requirements.
CAUTION!
To avoid equipment damage, DO NOT use
these units as a source of heating or cooling during the
construction process. The mechanical components and
fi
lters will quickly become clogged with construction dirt
and debris, which may cause system damage.
WARNING!
All refrigerant discharged from this unit must
be recovered WITHOUT EXCEPTION. Technicians must
follow industry accepted guidelines and all local, state,
and federal statutes for the recovery and disposal of
refrigerants. If a compressor is removed from this unit,
refrigerant circuit oil will remain in the compressor. To
avoid leakage of compressor oil, refrigerant lines of the
compressor must be sealed after it is removed.
Safety
Warnings, cautions and notices appear throughout this
manual. Read these items carefully before attempting any
installation, service, or troubleshooting of the equipment.
DANGER: Indicates an immediate hazardous situation, which
if not avoided will result in death or serious injury. DANGER
labels on unit access panels must be observed.
WARNING: Indicates a potentially hazardous situation, which
if not avoided could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation or an
unsafe practice, which if not avoided could result in minor or
moderate injury or product or property damage.
NOTICE: Noti
fi
cation of installation, operation or maintenance
information, which is important, but which is not hazard-
related.
D = DXM2
5 = Motorized Valve (Modulating)
Closed Loop Applications, Low System Pressure Drop
6 = Motorized Valve (Modulating)
Open Loop Applications, High System Pressure Drop
5 0
J
0 2 4
C
D
3
1
1
2
4 5 6
7
8
10
11
12
9
PREFIX
024
UNIT SIZE
030
036
042
AIR FLOW CONFIGURATION
VOLTAGE
CONTROLS
1 = Single Pack, Domestic
PACKAGING
REVISION LEVEL
YFV
1 2 3
YFV = Vertical Upflow Residential
SERIES (Extended Range)
YFH = Horizontal Residential
Horizontal YFH
Option Return Discharge Filter
N
P
W
Y
Right
Right
Left
Left
Left
Back
Right
Back
1”
1”
1”
1”
Vertical Upflow YFV
Option Return Discharge Filter
J
K
Left
Right
Top
Top
1”
1”
Motor
ECM
ECM
ECM
ECM
Motor
ECM
ECM
048
1 = Current Revision
060
HEAT EXCHANGER OPTIONS
WATER CIRCUIT OPTIONS
2 = Internal Flow Controller High Head
13
3 = 208-230/60/1
No HWG
HWG W/Pump (Standard)
Copper Cupro-Nickel
A
C
J
N
In Position 11 and 12, only the following combinations are available:
Without HWG
With HWG
Description
2A
2C
Internal Flow Controller with Copper Water Coil
5A
5C
Motorized Modulating Valve with Copper Water Coil
6J
6N
Motorized Modulating Valve with Cupro-Nickel Water Coil
9
10,
WARNING!
NOTE: Above model nomenclature is a general reference. Consult individual specifi cation sections for detailed information.
WARNING!
The Puron
®
Application and Service Manual
should be read and understood before attempting to
service refrigerant circuits with HFC-410A.
Содержание 50YFH
Страница 2: ...This page was intentionally left blank ...