15

UNIT OPERATION

The air discharge direction can be controlled to swing up and down and can be fixed at a preferred position or at automatic position by the remote control.

If you select the flap position using the FLAP button in the remote control, the flap in the unit

will move to that position automatically.

Once you select the position, the unit remembers that position and whenever you turn on

the unit,  the flap will be positioned to that position.

If you select SWING, the flap will swing up and down. In the COOL, DRY and FAN mode,

the flap will swing in the cool range. In the HEAT mode, the flap will swing in the heat range.

If you select AUTO, the flap will position itself to the preset position according to the operation mode.

CLOSE

Remote Control

Auto Position

Swing Range

If you want to adjust the direction of the discharge air left or right, Pressing the

‘vertical louver’ button. The button will set the swing on and off.

COOL

HEAT

HEAT

Always use the remote control to adjust the flap position,

otherwise it may cause abnormal operation.

Please turn off the unit and turn it on again when you

manually adjust the flap out of range.

NOTE

DISCHARGE AIR LOUVER CONTROL

Up and Down Control

Left and Right Control

Please do not fix the flap at position   for a long time, because this position

minimizes air circulation resulting in uneven  room temperature.

Do not adjust the flap by the hand during SWING operation because it may

damage the air swing mechanism.

  If you want maximum cooling or heating capacity, please set flap at position  .

NOTE

Horizontal Louver setting 6 and

Vertical Louver Swing Indicater

Time

1sec

1sec

Swing on

Swing off

Vertical louver button

Содержание 42XPL030C3P

Страница 1: ...42XPL030C3P 38XPL030C3 42XPL030H3P 38XPL030H3 42XPL036C3P 38XPL036C3 42XPL036H3P 38XPL036H3...

Страница 2: ...ilt into your unit One of the pleasant benefits awaiting you with room air conditioning is that in addition to being cooled the room air is filtered and dehumidified This manual is designed to help yo...

Страница 3: ...ION FOR THE INTERCONNECTING PIPING INDOOR UNIT WIRING FORMING THE DRAIN HOSE AND REFRIGERANT PIPING INSTALLING THE INDOOR UNIT BODY TO THE WALL HANG BRACKET CONNECTING THE PIPING 28 CONNECTING PIPE TO...

Страница 4: ...re is in place CAUTION Do not switch off the split system by disconnecting the electric power supply The unit must always be switched off using the remote control WARNING Installation and servicing of...

Страница 5: ...e fan Use only fuses of the proper amperage PRECAUTIONS WARNING Keep heat sources away from the unit high temperature can cause damage Do not use circuit breaker as a means of turning off the unit The...

Страница 6: ...e unit with a wet hand there is a risk of Electric Shock Two or more people should lift and transport the product and use proper Safety precautions while lifting the product to avoid personal injury Y...

Страница 7: ...n are as follows Indoor Unit Display EMER button Can be used when the remote control is lost or inoperative EMER button Test Operation This operation is used for checking after unit installation Press...

Страница 8: ...o confirm it 5 The current hour figure flashes Press either button or to set the current hour Press button to move to minutes and set them Press reset button with a sharp object if the remote control...

Страница 9: ...it Remote control The air conditioner will not operate if curtained doors or other materials block the signals from the remote control to the unit If the infrared signal receiver on the unit is expose...

Страница 10: ...on Dehumidification only 2 Signal transmission symbol 3 Temperature selected 4 Address selector 5 Temperature unit of measurement C or F 6 Unit configuration 7 Batteries exhausted indicator 8 Vertical...

Страница 11: ...nit display illuminates MODE button Press this button to select the desired operation FAN SPEED button Press this button to select the desired fan speed TEMP button Press these buttons to set the desi...

Страница 12: ...mode is allowed TheAuto operation is not suitable for the application to the computer room or some food wine stock storage PROCEDURE 3 1 7 2 6 5 4 ON OFF button Press this button and the unit starts...

Страница 13: ...To definitively set the time press button again Operating mode Choose the unit operating mode The icons will flash To select the mode use the button Once the mode has been decided press button The ic...

Страница 14: ...either button or or To move from hour to minute press button Press button again to confirm 1 2 OFF timer procedure When the ON Timer function is operating the unit senses the room air temperature rig...

Страница 15: ...ws Select ON timer at 5 30 p m Select OFF timer at 10 30 p m Press the everyday button daily button 1 2 3 Cancellation of ON OFF and DAILY timer procedure If you want to cancel On or OFF timer setting...

Страница 16: ...ul capacity at Cooling and Heating mode press During Turbo mode you cannot control room temperature and fan speed press one of the buttons or to cancel the turbo mode button On the display the powerfu...

Страница 17: ...e CLOSE Remote Control Auto Position Swing Range If you want to adjust the direction of the discharge air left or right Pressing the vertical louver button The button will set the swing on and off COO...

Страница 18: ...In case of fire remote ON OFF switching of the system is possible In addition the ON OFF switching through the remote control can be locked However an adaptor and wiring connected to the central contr...

Страница 19: ...smetics can accumulate while room air circulates through the unit Cleaning the filters will reduce this problem UNIT ON lamp on the indoor unit displays flashes and no air comes from the unit It indic...

Страница 20: ...ower plug before cleaning Clean the air filters once a month NOTE CARE AND MAINTENANCE CLEANING THE FILTERS AND FRONT PANEL Cleaning the Air Filter 1 2 3 Cleaning the Ioniser Clean Ioniser with a brus...

Страница 21: ...it and separate it from the unit Rinse the panel under running water and dry completely in a shaded area Refit it correctly Installation procedure is reverse to the removal procedure CLEANING THE MAIN...

Страница 22: ...2 F For indoor unit installation or fixing unit and hanging bracket 1 For wireless remote control mounting bracket Installation Screws 5xL25 14 For wall hanging bracket installation Wirele Wall hangi...

Страница 23: ...the following places may cause problems If it is unavoidable to use the unit in such places consult with your distributor A place with machine oil A saline place such as a seashore vicinity A place wi...

Страница 24: ...d the outdoor unit Max 20m Dripping due to insufficient insulation of pipes INSTALLATION TIPS The following points should be avoided Excessive distance between the indoor and the outdoor unit Max 40m...

Страница 25: ...ng the wall hang bracket remove it from the unit by pushing up marks at the bottom of the body Fasten the wall hang bracket to the wall with 14 or more self tapping screws through the holes marked at...

Страница 26: ...han the inside end to ensure good drainage Cut the Wall Sleeve to match the wall thickness and to pass the pipe through the hole Figure 6 Remove the knock out in the unit and pass the pipes through th...

Страница 27: ...always requires grounding Ground the unit must be in accordance with local codes Every wire must be connected firmly Use connection cable H07 H05 A07 A05 RN F 1 5mm2 synthetic rubber insulation with...

Страница 28: ...10 Pass the pipes through the wall sleeve and then hook the indoor unit body onto the top of the wall hang bracket Figure 12 For Left Piping hang the unit onto the top of the wall hang bracket and inc...

Страница 29: ...can be adjusted by securing 2 screws to the body and wall hang bracket Refer to the screw hole location A B in Figure 12 Removing the frame grille Detach terminal block cover by removing two screws a...

Страница 30: ...tening torque is insufficient gas will leak from the connection If it is too strong the flare will be damaged Tighten the nut with the torque shown in Table 1 Do not bend the pipe more than three time...

Страница 31: ...uring the disconnection please be cautious not to lose any refrigerant and oil h Reinstall the valve caps and service port nuts Figure 17 When the connection pipe is less than 7 5m extra amount of ref...

Страница 32: ...insulation and fasten it with vinyl tape Figure 18 19 Fill the gap between the inside of wall sleeve and the pipe with a sealer so that rain and wind does not enter Figure 20 Figure 18 Figure 19 Pipe...

Страница 33: ...Be sure to comply with local codes on running the wire from the indoor unit to the outdoor unit Every wire must be connected firmly During installation proceed first with refrigerant connections betwe...

Страница 34: ...For Heat Pump Model CONNECTING THE POWER SUPPLY Model 38XPL030C3 38XPL036C3 38XPL030H3 38XPL036H3 Phase 60Hz 60Hz 60Hz 60Hz Fuse A 30 40 30 40 Wiresize mm2 4 0 4 0 4 0 4 0 Main power connection RCY m...

Страница 35: ...llowing conditions 1 Difference between indoor ambient temperature and indoor unit air discharge temperature must be greater than 3 C 2 Indoor fan must operate at low speed 3 Louver must be in auto he...

Страница 36: ...tedly until HR or CR is displayed Press either the or button to change the default value of Maximum heating setpoint or minimum cooling setpont Press button repeatedly until CL is displayed 11 2 3 4 5...

Страница 37: ...new value A or b Press button repeatedly until ZONE is displayed Press either the or button to change the default value of Zone number 0 to the new value 0 240 Press button repeatedly to configure Au...

Страница 38: ...necessary Cooling is Are the windows or doors open Close the windows and doors abnormally low Is anything obstructing the outdoor unit Remove the obstruction Is the fan speed too low Change the fan s...

Страница 39: ...3 8 78 11 9 2 26 2 15 2 70 2 64 3 19 2 64 3 19 28500 25000 23 51 6102 6102 7128 7128 23 58 23 54 23 61 3 53 9 9 9 4 11 8 11 9 11 7 14 1 11 7 14 1 2 66 8000 9400 27000 24000 32500 28500 31500 28000 42X...