Exploded view & spare-part
24
P9
Protection of defrosting or anti-cold wind
E1
Open-circuit and short-circuit of temperature sensors T1
E2
Temp. sensor T2 on indoor evaporator is open circuit or short circuit
E3
The condenser temperature sensor T3 is open or short
E6
Protection of outdoor unit
8.2.1
LEDs for the indication of outdoor trouble
In normal operation, LEDs emit no light and they will flash at a frequency of 5 Hz when
trouble occurs. Their codes are listed in the following table:
LED1
LED2
LED3
Contents
Off
Off
On
Ok
On
Off
On
Phase sequence error
Off
On
On
Overload of current
On
On
On
Lack of phase
8.3
Troubles and Solutions
Before calling for service, please review the following list of common problems and
solutions.
If any of the following conditions occur, check your unit and resolve corresponding
problems referring to given remediation. If the trouble can't be settled contact our
dealer.
Trouble
Cause
Solutions
Unit does not
start
Power failure.
Wait for the comeback of
power
Power switch is open.
Switch on the power
Fuse of power switch may have
blown.
Replace the fuse
Batteries remote controller are
exhausted.
Replace the batteries
The time is not start-up time you
have set.
Wait or cancel the time set.
Air flowing
normally with
low
cooling(heating)
effect
Temperature is not set correctly.
Set the temperature
properly.
Door or window is open.
Close door and window.
Air filter is blocked with dust or
dirtiness.
Clean the air filter.
Inlet/outlet of indoor/outdoor units
are blocked.
Clear all blockages.
Inlet/outlet of indoor/outdoor units
are blocked.
Clear the blockage, then
restart your operation.
Содержание 42/38KCJ024713
Страница 7: ...External view and display 5 3 2 Display panel ...
Страница 8: ...Refrigerant cycle diagram 6 4 Refrigerant cycle diagram 4 1 Cooling only 4 2 Heat pump model ...
Страница 10: ...PCB drawing Wiring diagram 8 Outdoor unit 5 3 42 38KCJ036713 Indoor unit ...
Страница 11: ...PCB drawing Wiring diagram 9 Outdoor unit 5 1 42 38QCJ036713 Indoor unit ...
Страница 12: ...PCB drawing Wiring diagram 10 Outdoor unit 5 1 42 38KCJ048713 Indoor unit ...
Страница 13: ...PCB drawing Wiring diagram 11 Outdoor unit 5 1 42 38QCJ048713 Indoor unit ...
Страница 14: ...PCB drawing Wiring diagram 12 Outdoor unit ...