Indoor units with horizontal construction designed for installation 
indoors, connected to a network of ducts.

•  1 circuit: 

  Models: 90 / 100 / 120 / 160 / 180 / 182

•  2 circuits: 

  Models: 200 / 240 / 320 / 360 / 420 / 485 / 540 / 600

They  are  equipped  with  centrifugal  fan  (EC  plug-fan  also 
available in models 90 to 360), and expansion valve.

A vast number of options meet numerous operating demands.

All of the units are tested and checked in the factory.

The units comply with European Directives: 

● Machinery Directive 2006/42/EC (MD)

1 - INTRODUCTION

● Electromagnetic Compatibility Directive  2014/30/EU (EMC)

● Low Voltage Directive 2014/35/EU (LVD)

● Pressure Equipment Directive 2014/68/EU (Category 2) (PED)

● RoHS Directive 2011/65/EU (RoHS)

● Eco-design Directive 2009/125/EC (ECO-DESIGN)

● Energy Labelling Directive  2017/1369/EU (ECO-LABELLING)

● Harmonised Standard: EN 378-2:2012 (Refrigerating systems 

and heat pumps - Safety and environmental requirements).

Technicians who install, commission, operate and service the 
unit  must  possess  the  necessary  training  and  certifi cations, 
understand the instructions given in this manual and be familiar 
with the specifi c technical characteristics of the installation site.

2 - SAFETY ADVISE

To avoid any risk of accident during installation, commissioning 
or maintenance, it is obligatory to take into consideration the 
following specifi cations for the units: refrigerated circuits under 
pressure, refrigerant presence, electrical voltage presence and 
implantation place.

Because of all of this, only qualifi ed and experienced personnel 
can perform maintenance tasks or unit repairs. 

It  is  required  to  follow  the  recommendations  and 
instructions in this brochure, the labels, and the specifi c 
instructions. 

Compliance with the norms and regulations in eff ect is 
mandatory. It is recommended to consult the competent 
authorities  regarding  the  applicable  regulations  for 
users  of  units  or  components  under  pressure.  The 
characteristics  of  these  units  or  components  are 
included  on  the  plates  of  characteristics  or  in  the 
regulatory documentation provided with the product.

In case of a leak:

● Toxicity: According to EN 378-1, R-410A belongs to the A1/

A1 group, i.e. with high safety both in the mix and also in the 
case of a leak. 

● Although  it  is  not  toxic,  in  case  of  a  leak  to  atmospheric 

pressure the liquid phase evaporates. The resulting vapours 
are  still  hazardous  because  they  are  heavier  than  air  and 
can force the latter out of the machine rooms. If refrigerant is 
accidentally released, ventilate the room with fans.

● Although  it  is  not  fl ammable,  keep  them  away  from  open 

fl ames (e.g. cigarettes) as temperatures of over 300°C cause 
their vapours to break down and form phosgene, hydrogen 
fl uoride, hydrogen chloride and other toxic compounds. These 
compounds may produce severe physiological consequences 
if accidentally inhaled or swallowed.

●  To detect leaks, an electronic leak detector, an ultraviolet lamp 

or soapy water must be used . Flame detectors do not help.

● Immediately  repair  any  refrigerant  leak,  using  a  recovery 

unit  specifi c  for  R-410A  that  avoids  a  possible  mixture  of 
refrigerants and/or oils.

The  compressor  and  line  surfaces  can  reach 
temperatures above 100ºC causing burns to the body. 
In  the  same  fashion,  under  certain  conditions  these 
surfaces  can  reach  very  cold  temperatures  that  can 
cause freezing risks.

During any handling, maintenance or service operations, 
the technicians involved must be equipped with safety 
gloves, glasses, shoes, insulating clothing, etc

Caution: 

Before intervening in the unit, verify that the 

main power to the unit is cut off . An electric shock can 
cause personal damage. The main disconnect switch 
is located in the unit’s electric cabinet.

Components of the R-410A

R-32

R-125

Chemical formula

CH2F2

CHF2CF3

Weight ratio

50%

50%

Unitary global warming potential (GWP) 

675

3.500

Global warming potential (GWP) 

2.088

Refrigerant

Ensure  that  refrigerant  is  never  released  to  the  atmosphere 
when the equipment is installed, maintained or sent for disposal.

It  is  prohibited  to  deliberately  release  refrigerant  into  the 
atmosphere.  The  operator  must  ensure  that  any  refrigerant 
recovered is recycled, regenerated or destroyed.

The operator is bound by the obligation to perform periodical 
sealing  tests  on  the  refrigerating  circuit  according  to  the 
regulation (EU) No.517/2014

Please, consult the frequency of 

tests in chapter of “Maintenance”.

All interventions on the refrigerating circuit must be performed 
in accordance with applicable legislation. Within the European 
Union, it is  necessary to observe regulation (EU) No.517/2014, 

known  as  F-Gas,  over 

Certain  greenhouse  eff ect  fl uoride 

gases.

Important:

  These  units  contain 

R-410A

,  a  fluorinated 

greenhouse gas covered by the Kyoto protocol.

Содержание 40ZF Series

Страница 1: ...Nominal cooling capacity 20 135 kW Nominal heating capacity 20 145 kW Indoor units INSTALLATION OPERATION AND M A I N T E N A N C E I N S T R U C T I O N S Translation of the original document 80259...

Страница 2: ...SSIONING 9 7 1 Electrical connections 9 7 2 Checks in the centrifugal fans 9 7 3 Checks in plug fans optional 10 7 4 Air ducts connections 11 7 5 Condensate drain connection 11 8 SAFETY ELEMENTS 12 9...

Страница 3: ...ak to atmospheric pressure the liquid phase evaporates The resulting vapours are still hazardous because they are heavier than air and can force the latter out of the machine rooms If refrigerant is a...

Страница 4: ...11 I MS221 I R N R N MC111 N E R I R MC011 MC021 N E R R I N N E E MC001 I I 40ZS ZF 420 to 600 assemblies with mixing box raised view N E MC101 R I I I I Designation 1 Rear Return 2 Top 3 Right hand...

Страница 5: ...t causing damage to the units or to workers These slings will be hooked to the two grips screwed on each crossbar in models 420 to 600 Make sure that the unit is protected from contact with the hooks...

Страница 6: ...0 705 1 044 MC0 1 088 1 350 660 1 224 MC1 1 148 1 350 930 1 697 40ZS ZF MS module Centre of gravity mm Weight kg X Y Z 90 100 120 Montajes 111 116 413 314 411 114 113 311 121 126 423 324 421 124 123 3...

Страница 7: ...ade With the help of the crane or the forklift truck the unit will be raised to a su cient height that the silent blocks can be screwed into its base The 4 silent blocks of the corners must remain obl...

Страница 8: ...600 1 300 2 061 40ZS ZF 90 to 360 40ZS ZF 420 to 600 6 3 Anchorage for silent blocks 6 4 Recommended service clearance for unit start up and maintenance operations mm 1000 1000 500 1700 500 1000 A 500...

Страница 9: ...fans Before commissioning check the blade rotation direction and that the axis turns without strokes nor vibrations Once running check the operation conditions pressures ows and consumptions The over...

Страница 10: ...entrifugal motorfans are coupled through pulleys and belts In these fans the following must be taken into consideration Pulley alignment The pulleys must be on the same plane so it is important to che...

Страница 11: ...G Models 90 to 360 These indoor units are equipped with a condensate drain pan with a bronze gas threaded 3 4 M drain junction Condensate drain CONNECT SIPHON METTRE SIPHON PONER SIFON V220014 7 5 Con...

Страница 12: ...nsidered when selecting fans the pressure drop graphs in the options can be seen in the technical brochure 9 1 Mixing box In models 90 to 360 of the 40ZS ZF unit the mixing box is a separate module Th...

Страница 13: ...imensions mm A B C 90 100 120 1 supply outlet 6 9 1 row 150 482 443 12 2 rows 262 482 443 160 180 1 supply outlet 12 15 18 1 row 189 1 142 443 182 200 240 2 supply outlet 15 18 1 row 189 1 142 443 24...

Страница 14: ...to connect the hose to the electric power supply If it is not possible to perform the previous step the distance between holes as well as the frame dimensions are displayed in the following schemes S...

Страница 15: ...se frames to the unit four supports are provided In the case of 2 frames screw each one of them to 2 supports with the four M4 screws included in the kit The height of the frame on the support will de...

Страница 16: ...l in the technical brochure of this series Water outlet Water inlet Models 40ZS ZF 90 to 360 Recomendations Coil lling The coil lling must be made with the bleeder valve open until water runs through...

Страница 17: ...re assembled over a sheet steel pro le Models 40ZS ZF 90 to 360 Modelos 40ZS ZF 420 to 600 Opacimetric filters Gravimetric filters Sheet profile Tab for displacement of gravimetric filters Tab for dis...

Страница 18: ...oise we recommend the use of noise dampening headgear Caution Before intervening in the unit cut o main power 10 1 General recommendations Do not lean on the unit A platform must be used to work on a...

Страница 19: ...ecovered for treatment Refrigerant Energy transfer uid depending on the installation water glycol water mix Compressor oil Important In order to recycle these units follow the stipulations of Directiv...

Страница 20: ...Order No 10259 12 2020 Supersedes order No 07 2019 Manufactured for CARRIER in Spain Manufacturer reserves the right to change any product specifications without notice Printed in the European Union...

Отзывы: