14
Wireless Remote Controller (40VM900001)
(included with the outdoor unit) —
Indoor unit ad-
dressing can be performed using the wireless remote controller.
When using the wireless controller, the user must maintain a
line of sight with the receiver on the indoor unit. See Fig. 25 for
a description of the buttons on the wireless remote.
Use a tool to press and hold the LOCK button for at least 10
seconds, then press
to activate. Click
or
to select an
address and press
to send the setting.
To display an indoor unit address, use a tool to press and
hold the LOCK button for at least 10 seconds, and press
to
query the addresses.
Non-Programmable Controller (40VM900002)
—
When setting an address, connect only one wired control-
ler to an indoor unit.
Press
ROOM TEMP
and
SWING
simultaneously for 3
seconds. If there is no address for this indoor unit, the display
shows
FE# 00
(see Fig. 26). Otherwise, the display shows the
current address of the indoor unit.
Click
TEMP. UP
or
TEMP. DOWN
to change 00 to the
desired address as shown in Fig. 27. Then press
OK
to confirm
and exit the setting interface.
Programmable Controller
(
40VM900003
) —
When setting an address, connect only one wired controller to
an indoor unit.
RESET
TIMER ON
TIMER OFF
CLOCK
SWING
AIR DIRECTION
OK
SWING
MODE
FAN
AUTO
COOL
DRY
HEAT
FAN
TEMP
SET
CLOCK
SET
HOUR
FAN SPEED
LOCK C/H
2 – FAN
S
PEED
S
ETTING
4 – ADJU
S
T UP
6 – AIR DIRECTION
9 – CLOCK
S
ETTING
10 – TIMER ON
11 – TIMER OFF
14 – OK (CONFIRM)
1 – MODE
S
ETTING
3
– ADJU
S
T DOWN
5 – ON/OFF
7 – AIR VERT.
S
WING
8
– AIR HORIZ.
S
WING
12 – RE
S
ET
1
3
– LOCK
15 – COOL/HEAT
A40-17
3
4
Fig. 25 — Wireless Remote Controller
(40VM900001)
FAN
MODE
MODE
FAN
TEMP. DOWN
TEMP. UP
OK
ON/OFF
TIMER
ROOM TEMP.
SWING
#
Fig. 26 — Non-Programmable Controller
(40VM900002) IDU Addressing Menu
#
MODE
FAN
TEMP. DOWN
TEMP. UP
OK
ON/OFF
TIMER
ROOM TEMP.
SWING
Fig. 27 — Non-Programmable Controller
(40VM900002) Setting IDU Address